background image

LT-3200 Switch

10

Warranty

Universal Remote Control, Inc. (“URC”) warrants that the URC equipment shall be free from defects in material and workmanship under
normal usage for one (1) year from purchase for all products with the exception of all Total Control® whole-house products which is for two
(2) years from purchase, when such is purchased from URC. This limited warranty is valid only in the United States of America. URC warrants
that the software will substantially conform in any material respect to its functional specifications at the time of delivery. URC shall not be
liable for operational, technical or editorial errors and/or omissions made in the URC documentation. URC does not warrant that the URC
software is bug-free or error free or that there are no errors/bugs in the URC software.URC equipment purchased from other than an
authorized URC dealer or distributor are without warranty.In the event of any warranty claim, URC will, at its sole option, repair the URC
equipment using new or comparable rebuilt parts, or exchange the URC equipment for new or rebuilt equipment. In the event of a defect,
these are the end user’s exclusive remedies. All the URC equipment returned for service, exchange or repair require an RGA number. To obtain
an RGA number, you must complete a Return Request Form which you may obtain by calling (914) 835-4484 or contacting URC at
[email protected]. To obtain warranty service, end user must deliver the URC equipment, freight prepaid, in its original
packaging or packaging affording adequate protection to URC at 37 Ramland Road, Unit 104, Orangeburg, NY 10962. It is end user’s
responsibility to backup any macro programming, artwork, software or other materials that may have been programmed into the unit. It is
likely that such data, software, or other materials will be lost during service and URC will not be responsible for any such damage or loss. A
dated purchase receipt, bill of sale, installation contract or other verifiable proof of purchase is required.For detailed information regarding
warranties and returns, please visit URC’s website available at http://www.urc-automation.com/warranty or call the Customer Service Center
at (914) 835-4484.

FCC Statement

This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.

This equipment should be installed and operated with minimum distance of
20 cm between the radiator and your body.

NOTE:

This equipment has been tested and found to comply with the

limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures.

• Reorient or relocate the receiving antenna.

• Increase the separation between the equipment and receiver.

• Connect the equipment into an outlet on a circuit different from

that to which the receiver is connected.

• Consult the dealer or an experienced radio/TV technician for help.

MODIFICATION: Any changes or modifications not expressly approved
by the grantee of this device could void the user’s authority to operate
the device.

IC Statement

This device contains licence-exempt transmitter(s)/receiver(s) that comply
with Innovation, Science and Economic Development Canada’s licence-
exempt RSS(s). Operation is subject to the following two conditions:

1. This device may not cause interference.

2. This device must accept any interference, including interference

that may cause undesired operation of the device.

L’émetteur/récepteur exempt de licence contenu dans le présent appareil
est conforme aux CNR d’Innovation, Sciences et Développement
économique Canada applicables aux appareils radio exempts de licence.
L’exploitation est autorisée aux deux conditions suivantes:

1. L’appareil ne doit pas produire de brouillage;

2. L’appareil doit accepter tout brouillage radioélectrique subi, même

si le brouillage est susceptible d’en compromettre le
fonctionnement.

This equipment complies with IC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and
operated with minimum distance of 20 cm between the radiator and your
body.

Cet ééquipement est conforme aux limites d exposition aux rayonnements
de la IC éétablies pour un environnement non contrôéé. Cet ééquipement
doit êêtre installé et fonctionner à au moins 20 cm de distance d un
radiateur ou de votre corps.

CAN ICES-003 (B) / NMB-003 (B)

Содержание LT-3200

Страница 1: ...urers All mains operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network Specifications Power 120V AC 60Hz Signal Frequency 908 42 MHz Operating Temperature Range 32 104 F 0 40 C Maximum Load 600W Incandescent 300W LED 150 CFL Approval UL Listed FCC IC Z Wave Plus Certified CAN ICES 003 B MB 003 B For indoor use Specifications subject to c...

Страница 2: ...which is looking for Z Wave devices within its radius Z Wave devices outside this radius will not be found and need to either be moved within the radius or use a repeating device to reach it The second example shows how a repeater can be used to reach a device outside of the initial radius Keep this in mind when building your own network and make sure to use the range estimator below ...

Страница 3: ...rated Concrete Stone 30cm 11 8 20 Aluminum Coating 1mm 0 04 100 Ceiling 30cm 11 8 70 Furniture Non wood 30cm 11 8 40 60 Glass No Metal Coating 5cm 2 0 10 Inner Wall 30cm 11 8 40 Iron Reinforced Concrete 30cm 11 8 30 90 Metal Grid 1mm 0 04 90 Outer Wall 30cm 11 8 60 Plaster 10cm 3 9 10 Pumice 30cm 11 8 10 Red Brick 30cm 11 8 35 Stone 30cm 11 8 30 Wood 30cm 11 8 40 60 ...

Страница 4: ...ly with permanently installed fixtures To install multiple switches remove the tabs as needed Unlike the LT 3200 Switch the heat sink tabs are not used and have no effect on performance Ce gradateur est conçu pour être utilisé uniquement avec des luminaires installés en permanence Pour installer plusieurs gradateurs supprimez les onglets si nécessaire Contrairement au LT 3200 Switch les languettes...

Страница 5: ...l Single Pole Installation Single Switch 3 Way Installation Line Load in Separate Boxes The LT 3200 can be used in a 3 way 4 way lighting installation The Master Load Controller must be defined in URC software Secondary controllers must be defined in URC software Multi Way will not work without prior programming Traveler Wire is not needed for Multi Way configurations of two or more LT 3200s Load ...

Страница 6: ...trigger a specific scene D Air Gap Switch This will cut the power to the load your switch is wired to LT 3200 Switch Including A Switch Below are the steps for including pairing a switch to a Gateway Plan Prep and Install Locate an area to install the switch that is within a recommend distance from the Gateway Walls ceilings and even furniture may degrade communication between devices Remember to ...

Страница 7: ...o confirm the settings were saved SmartStart SmartStart enabled products can be added into a Z Wave network by scanning the Z Wave QR Code present on the product with a controller providing SmartStart inclusion No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on in the network vicinity Security 2 DSK The DSK can be found on th...

Страница 8: ...d device 01 Local 02 3 way 03 3 way Local 04 Z Wave Hub 05 Z Wave Hub Local 06 Z Wave Hub 3 way 07 Z Wave Hub Local 3 Way 08 Timer 09 Timer Local 10 Timer 3 Way 11 Timer 3 Way Local 12 Timer Z Wave Hub 13 Timer Z Wave Hub Local 14 Timer Z Wave Hub 3 Way 15 All 01 15 15 1 5 Yes LED Indicator Color Sets the default color of the LED Bar 0 255 160 2 6 Yes LED Indicator Intensity Sets the intensity of ...

Страница 9: ...E_UPDATE_MD Factory Default You may factory reset the switch by holding down the Config Button for twenty 20 or more seconds The LED Bar will turn Red and blink three 3 times to confirm However we recommend using a certified Z Wave controller to remove the device from your network for factory resetting the switch Only use either of these procedures in the event that the network primary controller ...

Страница 10: ... cause undesired operation This equipment should be installed and operated with minimum distance of 20 cm between the radiator and your body NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation Thi...

Отзывы: