City mains option
This option is the choice of the buyer and must be connected to your city water supply by a licensed
plumber. This option allows for automatic
FILL
and
DRAIN
of your unit.
The Urban Cultivator Residential should be connected to cold water from your city main’s supply located
within five feet from the Cultivator.
The unit also needs to be connected to your city drain that should be no higher than two feet from
ground level. The unit is intended to be permanently connected to the city mains supply and not
connected by a hose-set.
The water hose is located in the accessories bag and comes with a 3/8” hose connection. Connect the
valve from your Urban Cultivator Residential to your city water line and vacuum breaker which should
supply a water pressure of around 60psi for the Urban Cultivator Residential to be able to fill and drain its
reservoir effectively. (Once everything is connected,
switch to city mode
under menu options.)
To check the SET MODE OPTION to select CITY Mode on your unit:
Unlock Screen
for 3 seconds.
Press Menu
to get to SET MODE.
Press Enter
to select.
Press Up
to CITY MAINS
Press Enter
to select.
Pipes that have not been in regular use should be cleaned with running water before
connecting the Urban Cultivator Residential.
Make sure that the water inlet and drain hoses are free of debris or dirt and are not twisted,
crushed, entangled, or leaking in any way. Do not use connection hoses that have been used
previously by other appliances.