Urban Cultivator Residential Скачать руководство пользователя страница 13

13

Urban Cultivator | 1-877-352-0490 | www.urbancultivator.net

The control panel

The control panel controls the automated function of your Urban Cultivator Residential. You can 
customize the program using the menu outlined below:

Set Date & Clock

Set Temp C/F

Set lights Time

Set Water On Time

Set Recycle Rate

Top Up Reservoir

Air Pump 
On/Off/Cycle

Set Mode

Urban Cultivator

Select Date & Clock.

Set Temp display and Fan Control.
(18 C is recommended).

Set the time for lights to turn on.

Control how long to water your plants 
for. Factory default is 5 minutes
(recommended).

Control how often to drain and fill the 
reservoir. 7 days is recommended.

*If connected to city water.

Turning off is not recommended

Select between standalone 
& city mains.

This displays  your program version 
number.

Menu Headings

Pressing the menu button 

scrolls through all the menu options

A city water connection fully automates 

plant watering and reservoir water levels.

3

1

2

3

4

5

6

7

8

9

10

1

On/Off

Turns the Urban Cultiva-

tor Residential on and 

off. Will turn off all 

schedules and lights.

12 hours on, 12 hour off.

18 hours on 6 hours off 
(8am is the recommended 
start time)

Always on.

2

Lighting Cycles

Scroll up the menu.

4

5

Scroll down the menu.

6

Press enter to confirm 

your selection for all 

available options.

01:46:29 PM 

65ºF

17/08/2016  

50% RH

01:46:29 PM 

65ºF

17/08/2016  

50% RH

7

Display

Time

Temperature

Date

/Reserve Level

Relative 

Humidity

Top Watering Cycle

Select schedule.

Once in 2, 3 or 4 days.
(3 is recommended)

Manual Cycle immediately waters 
your plants then sets your chosen 
schedule.

Always off.

Twice per day.

Once per day.

8

9

Bottom Watering Cycle

Select schedule.

NOTE:- After selecting watering schedule you 

must select manual water to set day 1 of the 

cycle.

Recycle Reservoir

Select when you 

want to manually 

drain and fill the 

Reservoir.

Drain Reservoir - 
Yes or No

Fill Reservoir -  
Yes or No (City Mains Only)

10

Safety Lock

Hold both buttons together for 3 second to unlock the Control 

Panel.

The Control Panel will lock after 60 seconds of inactivity.

Содержание Residential

Страница 1: ...The Urban Cultivator Residential User Manual...

Страница 2: ...e manual These symbols are used to highlight important information Warnings Information and best practices Environmental information If you are unclear about any aspect of information in this manual p...

Страница 3: ...onal Installing counter top optional Connecting the Power Water and Electricity How Your Urban Cultivator Residential Works The grow drawers The control panel Planting your first herbs and microgreens...

Страница 4: ...Safety precautions in daily use Do not sit or stand on the open door Contaminated items and or garbage must not be present in the Urban Cultivator Residential Do not remove the grow trays or lighting...

Страница 5: ...l has been designed to fit under a North American kitchen counter top or work surface as a single cupboard unit It can slide between other cupboards and only requires one opening at the front While no...

Страница 6: ...ow 10 1 Control Panel 2 Door 3 Top Drawer 4 Humidity Domes 5 Bottom Drawer 6 Right Tray 7 Left Tray 8 Reservoir 9 Utilty Connections 10 Accessories Fragile Components Grow Lights x4 Glass Panel Thumb...

Страница 7: ...us and an unsafe plug inserted into a power socket could result in a serious safety hazard Do not connect the Urban Cultivator Residential via an extension cable Ensure that the plug is still accessib...

Страница 8: ...it Unlock Screen for 3 seconds Press Menu to get to SET MODE Press Enter to select Press Down to NO PLUMBING STANDALONE Press Enter to select To DRAIN water manually When the button is flashing green...

Страница 9: ...th a 3 8 hose connection Connect the valve from your Urban Cultivator Residential to your city water line and vacuum breaker which should supply a water pressure of around 60psi for the Urban Cultivat...

Страница 10: ...of your Urban Cultivator Residential 3 Secure castor wheels to the unit using the same bolts x4 x1 X 4 Installing countertop stand alone model To install the countertop piece 1 Remove the four black p...

Страница 11: ...to adjust its overall height from 34 to 34 Ensure product is level Leave 1 clearance gap for the door swing and handle when installing the Urban Cultivator Residential adjacent to a wall Water In Cit...

Страница 12: ...T grow drawer is installed when there is a watering program set Urban Cultivator will not be held responsible for any losses arising from water pumping from the top level without the drawer properly i...

Страница 13: ...rvoir water levels 3 1 2 3 4 5 6 7 8 9 10 1 On Off Turns the Urban Cultiva tor Residential on and off Will turn off all schedules and lights 12 hours on 12 hour off 18 hours on 6 hours off 8am is the...

Страница 14: ...Tightly Closed Screen not needed for Residential OR soil free grow mat PUT THE HUMIDITY DOME BACK ON if necessary TWO WAYS TO HARVEST Thin out greens and use as they grow Harvest all greens Amount of...

Страница 15: ...very 4 days 40g Piquant Mizuna 1 tbsp 2 3 days 2 weeks 1 every 4 days 124g Sharp Mustard 1 tbsp 2 3 days 2 weeks 1 every 4 days 200g Wasabi Nasturtium cup 4 7 days 1 2 weeks 1 every 4 days 290g Wild O...

Страница 16: ...cally Yes you can grow specific microgreens using our Fabric Sheets available from our online store It requires different nutrients watering schedule and procedure indicated on the package See our Pla...

Страница 17: ...ed Yes if you chose the CITY MAINS MODE and your cultivator is plumbed into your main water supply If you chose the STANDALONE MODE no it will not keep itself filled you will need to do this manually...

Страница 18: ...emove trays and drawers from cultivator 2 Wash with hot soapy water and rinse thoroughly NOT DISHWASHER SAFE every month every month every month Additional cleaning every 3 months Clean out the pipes...

Страница 19: ...r of the grow drawer must be soaked in Hydrogen Peroxide solution once a month CFIA has approved 2 chlorine from Calcium Hypochlorite as a seed sanitation method before sprouting this is not necessary...

Страница 20: ...ow an extra 1 5 38mm of clearance space if you are installing your Cultivator into a corner enclosure The additional space is clearance for the Cultivator s door handle The door must be able to open a...

Страница 21: ...city water hook up only Remove all the product packaging before positioning the Urban Cultivator Residential The city hook up version needs to be no more than five feet from the city water connection...

Страница 22: ...tee Conditions Urban Cultivator Limited guarantee that if within 12 months labour or within 3 years parts of the date of purchase this Urban Cultivator Residential appliance or any part thereof is pro...

Отзывы: