![Urban Cultivator Residential Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/urban-cultivator/residential/residential_user-manual_1061601013.webp)
13
Urban Cultivator | 1-877-352-0490 | www.urbancultivator.net
The control panel
The control panel controls the automated function of your Urban Cultivator Residential. You can
customize the program using the menu outlined below:
Set Date & Clock
Set Temp C/F
Set lights Time
Set Water On Time
Set Recycle Rate
Top Up Reservoir
Air Pump
On/Off/Cycle
Set Mode
Urban Cultivator
Select Date & Clock.
Set Temp display and Fan Control.
(18 C is recommended).
Set the time for lights to turn on.
Control how long to water your plants
for. Factory default is 5 minutes
(recommended).
Control how often to drain and fill the
reservoir. 7 days is recommended.
*If connected to city water.
Turning off is not recommended
Select between standalone
& city mains.
This displays your program version
number.
Menu Headings
Pressing the menu button
scrolls through all the menu options
A city water connection fully automates
plant watering and reservoir water levels.
3
1
2
3
4
5
6
7
8
9
10
1
On/Off
Turns the Urban Cultiva-
tor Residential on and
off. Will turn off all
schedules and lights.
12 hours on, 12 hour off.
18 hours on 6 hours off
(8am is the recommended
start time)
Always on.
2
Lighting Cycles
Scroll up the menu.
4
5
Scroll down the menu.
6
Press enter to confirm
your selection for all
available options.
01:46:29 PM
65ºF
17/08/2016
50% RH
01:46:29 PM
65ºF
17/08/2016
50% RH
7
Display
Time
Temperature
Date
/Reserve Level
Relative
Humidity
Top Watering Cycle
Select schedule.
Once in 2, 3 or 4 days.
(3 is recommended)
Manual Cycle immediately waters
your plants then sets your chosen
schedule.
Always off.
Twice per day.
Once per day.
8
9
Bottom Watering Cycle
Select schedule.
NOTE:- After selecting watering schedule you
must select manual water to set day 1 of the
cycle.
Recycle Reservoir
Select when you
want to manually
drain and fill the
Reservoir.
Drain Reservoir -
Yes or No
Fill Reservoir -
Yes or No (City Mains Only)
10
Safety Lock
Hold both buttons together for 3 second to unlock the Control
Panel.
The Control Panel will lock after 60 seconds of inactivity.