OPERATOR’S MANUAL
with Maintenance Information
Safety Rules
2
Electrocution Hazards
This machine is not electrically insulated and
will not provide protection from contact with or
proximity to electrical current.
Maintain safe distances from electrical power
lines and apparatus in accordance with
applicable governmental regulations and the
following chart.
Voltage
Phase to Phase
Minimum Safe
Approach Distance
Meters
0 to 300V
Avoid Contact
300V to 50KV
3.05
50KV to 200KV
4.60
200KV to 350KV
6.10
350KV to 500KV
7.62
500KV to 750KV
10.67
750KV to 1000KV
13.72
Allow for platform movement, electrical line
sway or sag and beware of strong or gusty
winds.
Keep away from the machine if it contacts
energized power lines. Personnel on the ground
or in the platform must not touch or operate the
machine until energized power lines are shut
off.
Do not operate the machine during lightning or
storms.
Do not use the machine as a ground for
welding.
Tip-over Hazards
This machine is intended for use
INDOORS
ONLY
, and must not be used outdoors as
wind forces may make it unstable.
Occupants, equipment and materials must not
exceed the maximum platform capacity.
Maximum capacity – SPX10
Maximum occupants 2
Maximum platform capacity 240 kg