background image

10

48V100Ah - Energy Storage Lithium Battery Module - User Manual

If there is no voltage output after the battery is restarted, connect the battery to the host computer and check 
whether the battery voltage and temperature are normal.

Generally cannot discharge the reason is: temperature protection, over current protection, under voltage protection.

5.1

 Leaking Batteries If the battery module leaks electrolyte, avoid contact with the leaking liquid or gas.

If one is exposed to the leaked substance, immediately perform the actions described below:

 Evacuate the contaminated area, and seek medical attention.

 If the body comes into contact with harmful substances such as electrolytes, wash it thoroughly with soap and 

water immediately. If you feel unwell, seek medical attention immediately. 

5.2

 

If smoke or open flame is found in the battery, use only a dry powder extinguisher. If possible, the battery should be 

removed and placed in a safe place before the battery module catches fire to avoid greater damage.

5.3

 Damaged batteries are dangerous and must be handled with great care. If faulty batteries need to be stored, store 

them in a special warehouse and take fire control measures. 

5.4

 

If the electrolyte of the battery is found to leak, then the battery needs to be scrapped, contact a professional battery 

recycling company in your area.

5. Emergency Measures 

Paseo de Extremadura, 39 - 28935 Móstoles - Madrid (Spain)

Tel. +34 918 021 649 - Fax. +34 917 750 542

[email protected]

www.masterbattery.es/en

Содержание UE48LI100-3U

Страница 1: ...Information Version 1 0 48V100Ah LFP Product Energy Storage Lithium Battery Module User Manual...

Страница 2: ...s State RUN light green LED ashing to show the battery running status RUN Alarm light The red LED blinks to indicate that the battery is alarming and the red LED blinks to indicate that the battery is...

Страница 3: ...in hibernation state press the button for 3 seconds and release it BMS will be activated and the battery will return to normal working mode 2 Manual sleep When the battery is in the normal working sta...

Страница 4: ...When the batteries are in parallel address 1 is the host and other addresses are slave The battery at address 1 is connected to the inverter If the address is 0 it is in single battery mode For detail...

Страница 5: ...address 2 05 48V100Ah Energy Storage Lithium Battery Module User Manual Schematic diagram of battery parallel installation Note The battery should be turned off during installation After installation...

Страница 6: ...idental electric shock or short circuits If insulated tools are not available cover the entire exposed metal surfaces of the available tools except their tips with electrical tape When installing batt...

Страница 7: ...terminal of the inverter DC input to the negative terminal of the battery 3 4 Connect the positive wires Connect all the positive terminals of the battery Finally connect the positive terminal of the...

Страница 8: ...verter This end connects to the Remote Box of the inverter This port connects to the RS485 port of the battery Note This communication line should be connected with attention to the direction Paseo de...

Страница 9: ...is too high or not if it is to change the settings on power supply side Low Voltage When the battery discharges to 44 5V or less battery protection will turn on Solution Charge the battery for some ti...

Страница 10: ...ul substances such as electrolytes wash it thoroughly with soap and water immediately If you feel unwell seek medical attention immediately 5 2 If smoke or open ame is found in the battery use only a...