6. Dimensional Drawing
Discharge over current protection
300~500A
Over current
Protection delay time
0.5s~2s
Over current release method
Delay about 8S after recovery
Battery
temperature
Charge over temperature
Protection @65±5°C
Discharge over temperature
Release @50±5°C
Protection @65±5°C
Release @50±5°C
Short circuit
Do not short-circuit the electrodes
Designed For 600A /1ms
Charge low temperature protection
Protection @-10±5°C
MOSFET over temperature protection
Release @75±10°C
Protection @103±10°C
Release @0±5°C
Items
Specification
Content
Over-discharge protection for each cell
2.0±0.05V
Over discharge
Over-discharge release for each cell
2.5±0.05V
Over-discharge release method
Charge to recovery
04
Unit: mm
200
386.6
M8*2pcs
483.5±3
170±3
241±3
www.upowerbatteries.com
NA
-12Li200BL