![Uponor Smatrix Base PULSE Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/uponor/smatrix-base-pulse/smatrix-base-pulse_installation-and-operation-manual_1060945023.webp)
uponor.com l 21
Chapter 6:
Wiring
This section explains how to wire various hardware
components in the Smatrix Pulse system. Before beginning
the wiring process, ensure all hardware is mounted and
installed per the instructions in
Chapter 5: Installation
.
Controller
Connecting the Actuators
Refer to the following information to properly connect the
actuators.
Note
Each thermostat can control one or more channels
and will control the associated actuator output.
To simplify installation and maintenance, Uponor
recommends wiring actuators controlled by the
same thermostat in sequence to the channels.
Note
Uponor recommends identifying the thermostat
room name or zone number with individual loops
to be controlled on the manifold.
1. Remove the cover
from the controller
(and Expansion Module,
if installed).
2. Route the wires from
the actuator through
the cable entries in
the bottom of the
Controller case.
3. Ensure the two actuator
wires are stripped to
approximately
33
/
88
" (9.5 mm).
4. Using a small screwdriver, press and hold the white
button on the quick connector.
5. Insert the wire into the opening.
6. Remove the screwdriver from the quick connector.
7. Repeat for the second wire and for the additional
actuators.
General Purpose Input (GPI) Switch
The controller includes a set of terminals that can be
used to change system operation. The default operation
is set for Heating/Cooling switchover. When the switch is
open, the system will be in Heating mode. When closed,
it switches the system over to Cooling mode. The GPI can
also be used to change the system from Comfort to ECO
mode (setback) but will require the installation of the
Communication Module and the Smatrix Pulse App to
change this setting.
Note
In systems where a Communication Module is
installed, the functionality of the GPI is selected
in the Installer Settings or in the System Settings
Menu.
Caution!
If using the GPI for Comfort/ECO mode, use only
one switch for the entire system.
Figure 6-1: Connecting
actuators
Figure 6-2: GPI wiring
• Ensure the power is
disconnected from both
the Controller and the
Heating/Cooling switch
source
• Remove the cover from
the Controller.
• Open the wiring
compartment using a
T-10 bit.
• Route the wires from the
Heating/Cooling switch
through the cable entry
above the contacts.
• Ensure the two actuator
wires are stripped to
approximately
33
/
88
"
(9.5 mm).
• Insert the wires into the
terminal blocks and
tighten with a small
screwdriver.
Содержание Smatrix Base PULSE
Страница 1: ...Smatrix Pulse Installation and Operation Manual...
Страница 8: ...6 l Smatrix Pulse Installation and Operation Manual...
Страница 16: ...14 l Smatrix Pulse Installation and Operation Manual...
Страница 22: ...20 l Smatrix Pulse Installation and Operation Manual...
Страница 28: ...26 l Smatrix Pulse Installation and Operation Manual...
Страница 40: ...38 l Smatrix Pulse Installation and Operation Manual...
Страница 42: ...40 l Smatrix Pulse Installation and Operation Manual...
Страница 60: ...Notes 58 l Smatrix Pulse Installation and Operation Manual...
Страница 61: ...Notes uponor com l 59...