Uponor Smatrix Base PULSE Скачать руководство пользователя страница 1

Smatrix Pulse

Installation and Operation Manual

Содержание Smatrix Base PULSE

Страница 1: ...Smatrix Pulse Installation and Operation Manual...

Страница 2: ...148th Street West Apple Valley MN 55124 USA T 800 321 4739 F 952 891 2008 Uponor Ltd 6510 Kennedy Road Mississauga ON L5T 2X4 CANADA T 888 594 7726 F 800 638 9517 uponor com 2022 Uponor All rights res...

Страница 3: ...ter 5 Hardware Installation 15 Installation Procedure 15 A380265C A380265A Controllers 16 A3801263 Expansion Module M 262 17 Communication Module R 208 17 Antenna A 265 18 A3801263 Relay Module M 263...

Страница 4: ...without notice Note that Uponor is not liable for installation practices that deviate from this manual or are not acceptable practices within the mechanical trades codes or standards of practices If...

Страница 5: ...t connected to or used with non Uponor products parts or components except for those approved or specified by Uponor and Does not show evidence of tampering mishandling insufficient maintenance improp...

Страница 6: ...adio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or...

Страница 7: ...annot accept any responsibility for damage or breakdown that can result from ignoring these instructions Power Warning The Uponor system uses 115V 60 Hz AC power In case of emergency immediately disco...

Страница 8: ...6 l Smatrix Pulse Installation and Operation Manual...

Страница 9: ...fferent types of Smatrix Pulse thermostats in the same installation Wireless relays provide installation flexibility when needing to control other heating and cooling devices when running additional w...

Страница 10: ...y requires Communication Module Invert display color Communication distances up to 98 ft 30 m away from the controller Included Components Digital Thermostat T 169 Wall bracket Adhesive tape Battery C...

Страница 11: ...O mode ECO mode activates in all rooms at once using a dry contact or Smatrix Pulse App requires Communication Module 115V plug in power cord 42 Options App connectivity via Communication Module remot...

Страница 12: ...om the controller when used as a sub Controller 115V plug in power cord 42 Options Increase Controller functionality by adding an Expansion Module that adds six 6 additional thermostats and six 6 addi...

Страница 13: ...tes the actual energy need of single rooms or zones and adapts the output power of each loop to its length This means a short loop might get 20 on time while a long loop might get about 60 The autobal...

Страница 14: ...in the floor Air cooling delivered via conventional air conditioning or fan coil units connected to a relay module registered to a room thermostat Note If selecting air cooling as the primary method t...

Страница 15: ...e optional When using the relay module to control a pump the mode of the pump control is set through in the Smatrix Pulse App Caution Changing operation of the pump control and or cooling allowed in t...

Страница 16: ...14 l Smatrix Pulse Installation and Operation Manual...

Страница 17: ...for Installation Verify the contents of the package with the packing list Check whether an external temperature sensor e g floor sensor is to be installed with a thermostat Review the wiring diagram...

Страница 18: ...mal operation The timer is reset when a button has been pressed If programmed schedules exist individual rooms may operate without following a schedule Setting up a system for remote access and connec...

Страница 19: ...extend the tab Angle the Expansion Module away from the wall Remove the Expansion Module from the DIN rail Communication Module R 208 The Communication Module contains both an antenna for internal con...

Страница 20: ...Install the Antenna outside a manifold cabinet Caution Install the Antenna vertically to ensure the best communication Mounting the Antenna Attach the Antenna to the wall using the adhesive strips inc...

Страница 21: ...erence or location for the specific Controller This will help once it is time to begin the registration process of linking the thermostats to the correct devices Note Remove the breakout tab on the th...

Страница 22: ...20 l Smatrix Pulse Installation and Operation Manual...

Страница 23: ...screwdriver from the quick connector 7 Repeat for the second wire and for the additional actuators General Purpose Input GPI Switch The controller includes a set of terminals that can be used to chan...

Страница 24: ...bles 6 1 and 6 2 1 H C Switch and Chiller is only available when cooling is activated 2 Function only available when Pump management is set to Individual otherwise Not used is shown in the Smatrix Pul...

Страница 25: ...relay closes when ECO mode is activated and open when the system returns to Comfort mode Ventilation The relay is closed when the system is set to ECO The ventilation unit must be setup to lower its...

Страница 26: ...3 8 8 9 5 mm Insert the wires into the terminal blocks and tighten Replace the cover Apply 24V power supply to the Relay Module The Relay Module can be wired to a furnace air conditioning system or f...

Страница 27: ...push buttons on the connection terminals While pressing the push buttons insert the two wires from the sensor cable non polarized into the connection terminal Powering Up the Thermostats Remove the pl...

Страница 28: ...26 l Smatrix Pulse Installation and Operation Manual...

Страница 29: ...green to solid red The Controller is in registration mode when the LED for Channel 1 flashes red If a thermostat has already been linked the first channel available will flash red A previously linked...

Страница 30: ...into pairing mode or to clear a link or registration to a thermostat 2 This will show the status of the Relay Module based on the various modes of operation During power up this LED will flash red an...

Страница 31: ...Controller can only have one Relay Module linked to it to mirror or duplicate the pump and boiler outputs This can be useful in installations when getting wiring back to the mechanical room for a zon...

Страница 32: ...em device Channel 01 or register to another Primary Controller To link a sub Controller to a Primary Controller use the following steps Enter the pairing mode on the Primary Controller one connected t...

Страница 33: ...ll remove links to all devices in the system Controllers Relay Modules thermostats etc Caution Resetting the Controller removes all registration information and settings Registration of thermostats an...

Страница 34: ...at while re inserting the battery Release the button after 10 seconds when the LED begins to flash Finishing the Installation Prior to making the system operational perform a complete review of the in...

Страница 35: ...chedules When the system is running in normal mode In Heating mode the actuators are open when room temperatures are lower than the temperatures set on the thermostats In Cooling mode the actuators ar...

Страница 36: ...Green Red Selector is pointed at a channel that is already registered to a thermostat Table 9 1 Controller LED mode of operation Communication Module Like the Controller s the Communication Module inc...

Страница 37: ...tting Table 9 4 Digital Thermostat T 169 button functions Display Mode Figure 9 5 shows the different symbol and characters that can be displayed when the thermostat is in the run mode Reference Descr...

Страница 38: ...rt screen Table 9 8 Digital Thermostat T 169 menu descriptions Menu 02 Heating Cooling Changeover This menu is not visible if the thermostat is registered to a Controller Heating cooling changeover wi...

Страница 39: ...ected to the system The setting is then available in the Smatrix Pulse App Menu 08 Display Units This menu sets the temperature information in F or C Menu 09 Relay Module Integration Use this menu to...

Страница 40: ...38 l Smatrix Pulse Installation and Operation Manual...

Страница 41: ...f technical support calls could have been averted if the updates were accepted and installed This only applies to systems that are connected to the Uponor Cloud have internet access and have an accoun...

Страница 42: ...40 l Smatrix Pulse Installation and Operation Manual...

Страница 43: ...or PC Router Requirements DHCP IP address assignment is activated in the router Wi Fi protected access is setup as WPA2 Personal or WPA WPA2 Personal Wi Fi connectivity is set at 802 11 b g n 2 4Ghz...

Страница 44: ...Fi router E connect using either Wi Fi or Ethernet The sub Controller D communicates via the Primary Controller C Remote Connection outside local Wi Fi network During normal operation outside the loca...

Страница 45: ...or the Antenna or if possible move the shielding object The transmitter in the thermostat is faulty Force the thermostat to transmit by changing the temperature setpoint Replace the thermostat Relativ...

Страница 46: ...s login and add the new installation Verify the smartphone or tablet is connected to the same network as the Communication Module Verify the network has internet access Communication error connecting...

Страница 47: ...ielding radio signals for example a metal door safe Try to find a new position for the thermostat and or the Antenna or if possible move the shielding object Low radio signal detected sporadic communi...

Страница 48: ...LED is fixed green Make sure the Communication Module is connected to an internet connected router via either Wi Fi or Ethernet Make sure the Communication Module is connected to the Controller Restar...

Страница 49: ...s not correctly positioned Check the placement of the thermostat so the signal is not shielded by another object The Antenna is not correctly installed or positioned Check the wiring and Antenna conne...

Страница 50: ...rong room The room is too cold or too warm in cooling mode Thermostat setpoint is too low Change the temperature setpoint Use maximum and minimum settings in the Smatrix Pulse App to protect the syste...

Страница 51: ...the supply line or a malfunctioning circulation pump Contact the installer if the problem persists Loop is warm even after an extended period without heat call The actuator s are not closing Contact...

Страница 52: ...lations in building shield radio signals for example a metal door safe Try to find a new position for the thermostat and or the Antenna or if possible move the shielding object The transmitter is work...

Страница 53: ...e tests EN 60730 1 and EN 60730 2 9 EMC electromagnetic compatibility requirements tests EN 60730 1 and EN 301 489 3 ERM electromagnetic compatibility and radio spectrum matters tests EN 300 220 3 Pow...

Страница 54: ...ly 24VAC 10 15 50 Hz or 60 Hz Pollution degree 2 Software class A Operating temperature 32 F to 122 F 0 C to 50 C Storage temperature 4 F to 158 F 20 C to 70 C Radio frequency 912 0 MHz Transmitter du...

Страница 55: ...lity to active parts of the product and degree of water Maximum ambient RH relative humidity 85 at 68 F 20 C Low voltage tests EN 60730 1 and EN 60730 2 9 EMC electromagnetic compatibility requirement...

Страница 56: ...A A Operating temperature 0 C to 45 C 32 F to 113 F 0 C to 45 C Storage temperature 20 C to 70 C 4 F to 158 F 20 C to 70 C Maximum consumption 45 W Pump and boiler relay outputs 24 VAC 10 15 8 A maxi...

Страница 57: ...from Controller to actuator 65 20 m 18 24 AWG External sensor cable to thermostat 16 4 5 m 18 24 AWG Floor sensor cable to thermostat 16 4 5 m 18 24 AWG Outdoor sensor cable to thermostat 16 4 5 m 18...

Страница 58: ...56 l Smatrix Pulse Installation and Operation Manual Digital Thermostat T 169 Mini Sensor T 161 Figure 13 3 Digital Thermostat T 169 Figure 13 4 Mini Sensor T 161...

Страница 59: ...6 40 4 26 099 45 7 22 763 50 10 19 900 55 13 17 436 60 16 15 311 65 18 13 474 70 21 11 883 75 24 10 501 80 27 9 299 85 29 8 250 Temperature Resistance F C 90 32 7 334 95 35 6 532 100 36 5 828 105 41 5...