4G CELLULAR

ALARM COMMUNICATOR

INSTALLATION (cont.)

F. Activating the 4550-CB Unit 

The 4550-CB is programmed OTA (Over-the-Air) by accessing the Uplink Dealer 
web site or by calling Uplink Customer Service at

 1-888-987-5465.

New Dealer 4550-CB Activation:

For new dealers/customers, establish an account with Uplink by visiting the Uplink 
web site

 (www.uplink.com)

.

 

a. Click on 

UPLINK DEALERS new/existing dealer access 

tab

.

 

b. Click on the 

New Dealer Signup

 button.

 

c.  Enter all information in the sign up form. Note: You must read and accept 

the terms of the Activation Agreement. Click the 

Setup

 button.

 

d.  A box will appear saying 

“If you want monthly service billed to a 3rd party such 

as a central monitoring station then you should NOT request an account – please 
contact Uplink Sales at 1-888-987-5465.”

 Click 

OK

.

 

e.  A confirmation box will appear saying 

“Congratulations, your new Uplink 

Account was successfully created!”

 Press 

OK

.

 

f.  Select the 

UPLINK DEALERS new/existing dealer

 button at the top of the 

page. Enter the newly created Login Name and Password to sign into the 
website. 

Wait about 20 seconds for the next web page to completely install.

 

g.  Select 

Activate Unit

 from the menu choices

.

 

h.  Answer 

“Yes”

 to the question 

“I have read and I accept the terms of the 

Activation Agreement”

.

 

i.  Enter the device serial number and select 

Activate.

 

j.  Enter all appropriate customer information

.

 

k.  From the 

Central Station Notification

 drop down menu, select the appropriate 

format

.

 

l.  Enter the appropriate Central Station phone number and account number.

 

m.  Configure the device to meet your install needs

.

 

n.  Select 

Update

.

 

o.  From the 

Programming

 drop down menu, select 

Program Unit Over the Air.

 

p.  Set the appropriate Dialer Protocol select 

Send

.

(INSTALLATION continued next page)

Содержание 202132UP455012

Страница 1: ...INSTALLATION USER S GUIDE PRODUCT ID 202132UP455012 4G CELLULAR ALARM COMMUNICATOR WIRELESS COMMERCIAL SECURITY APPLICATIONS PRIMARY OR BACKUP COMMUNICATIONS 4550 CB...

Страница 2: ...or information storage and retrieval systems The material in this manual is subject to change without notice Uplink reserves the right to make changes to any software or product to improve reliabilit...

Страница 3: ...15 32 A General Considerations 15 B DIP Switch Settings 15 C LEDs 16 18 D Locating and Installing the 4550 CB 19 22 E Connecting the 4550 CB to the Alarm Panel Telephone Jack 23 25 F Activating the 4...

Страница 4: ...nt the 4550 CB will intercept the alarm panel s digital dialer output when the panel has an event to report and communicate with the panel as if it were a central station alarm receiver Once the 4550...

Страница 5: ...er output and substitute the GSM cellular network for the Public Switched Telephone Network as the communications path for sending event information C Panel to 4550 CB Cable Supervision Monitors conti...

Страница 6: ...y Restoral at 11 4 VDC It can also be programmed to report Loss of AC power to the central station This occurs at 102 VAC and restores at 107 VAC G Automated Testing Sends an automated test signal to...

Страница 7: ...ent transmissions c initiation of a test report d the ability to query the unit and receive a real time radio report status including a Received Signal Strength reading e programming inputs and other...

Страница 8: ...because of a defect in materials or workmanship within the 12 month warranty period Uplink will at its sole option and at no charge repair or replace it or arrange for its repair or replacement Uplin...

Страница 9: ...THE FORESEEABILITY OF SUCH DAMAGES NEITHER UPLINK NOR ITS SERVICE PROVIDERS SHALL BE LIABLE FOR ANY CLAIM RESULTING FROM OR RELATING TO A THIRD PARTY CRIMINAL ACTIVITY OR FRAUD B ACTS OR OMISSIONS OF...

Страница 10: ...LITY WAIVER cont MORE RELATED OR UNRELATED CLAIMS EXCEED AN AMOUNT EQUAL TO THE AGGREGATE AMOUNT PAID BY THE CLAIMANT FOR UPLINK SERVICE DURING THE 12 MONTH PERIOD PRECEDING THE DATE OF THE EARLIEST E...

Страница 11: ...uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that...

Страница 12: ...number of devices that may be connected to a telephone line Excessive RENs on a telephone line may result in the devices not ringing in response to an incoming call In most but not all areas the sum o...

Страница 13: ...network the telephone company may request that you disconnect the equipment until the problem is resolved The 4550 CB is not designed to be repaired in the field by an Installer Repairs to this unit...

Страница 14: ...d international standards bodies The design of this module complies with the FCC guidelines and these international standards The FCC ID of this unit is TWV192513384X For more information about RF exp...

Страница 15: ...echnical support please ensure to have read the installation guide completely Technical support requires the caller to provide Login name Password Serial number of the 4550 CB UPLINK Technical Support...

Страница 16: ...d Proximity to the RJ31X Telco jack from the telephone system B DIP Switch Settings The 4550 CB has a four position dipswitch The dipswitches function as follows SWITCH NO SETTING FUNCTION S1 Default...

Страница 17: ...on for approximately 1 minute Then power must be removed and S1 restored to its OFF position All website configurations will be erased by using S1 C LEDs Normal Mode Upon initial power up the 5 LEDs...

Страница 18: ...on Line is off hook RED On Phone line Trouble Condition Trouble LED 3 GREEN On All 3 Output Relays Normal RED On One or more Output Relay Off Normal GSM Comm LED 4 GREEN On Unit registered on the netw...

Страница 19: ...solid 4 green solid 5 green solid 60 dBm lllll 1 off 2 green solid 3 green solid 4 green solid 5 green solid 70 dBm lllll 1 off 2 off 3 green solid 4 green solid 5 green solid 80 dBm lllll 1 off 2 of...

Страница 20: ...re as a template to mark where to drill holes for the screws and anchors that will hold the enclosure in place on the wall 2 Connect the supplied antenna with the 4550 CB The Antenna supplied may diff...

Страница 21: ...le To RJ31X House Phone Line To Alarm Panel To AC Transformer To Battery Note All Circuits are power limited except for battery connections A inch spacing is required between power limited circuits an...

Страница 22: ...n Figure 2 5 Place the backup battery into its location in the bottom of the enclosure Secure the battery in place using the metal battery bracket and nuts provided 6 Connect the positive and negative...

Страница 23: ...e that the RSSI is still showing a good signal strength level 9 Connect the unit s tamper switches For a single tamper switch connect the switch plug to the top of the left most column of JP13 For a d...

Страница 24: ...le On the 4550 CB s side the cable should use an RJ45 plug and be connected into Jack JP3 the Jack closer to the Terminal Strip 3 Inputs The 4550 CB has two EOLR supervised inputs that report to the c...

Страница 25: ...tputs that can be used to activate inputs on the alarm panel or for other local purposes Decide on how to use these outputs then wire them to terminal strip JP10 as follows Output 1 Out 1 and Out 1 Ou...

Страница 26: ...NG REQUIREMENTS AND INSTALLATION NOTES ALARM PANEL TO RJ31X Orange Wire 2 Blue Wire 7 Note To supervise the Telco cable connection to the Model 4550 CB unit short wires 2 and 7 together Model 4550 CB...

Страница 27: ...at 1 888 987 5465 Click OK e A confirmation box will appear saying Congratulations your new Uplink Account was successfully created Press OK f Select the UPLINK DEALERS new existing dealer button at t...

Страница 28: ...on I have read and I accept the terms of the Activation Agreement d Enter the device serial number and select Activate e Enter all appropriate customer information f From the Central Station Notificat...

Страница 29: ...arm states e What event codes should be sent for Low Battery and Low Battery Restoral f Whether alarm events should also be sent to an email account and the email account s address The following param...

Страница 30: ...ealer Web Site as Normally Open Normally Closed and whether the unit will send Alarms and Troubles or Alarms only 6 Definition of Output Relay Default 1 Loss of Cellular Service 2 Central Station ACK...

Страница 31: ...H Default Event Email Messages Email and Text Messaging will only be available for Status events e g Low Battery Test etc and state transitions on the 2 Inputs of the 4550 CB INSTALLATION continued ne...

Страница 32: ...ive c With the Telco Line still disconnected trip an alarm on the alarm panel Check that the 4550 CB has correctly intercepted the panel s digital dialer output and reported the event to the central m...

Страница 33: ...red to communicate via Contact ID protocol 2 Installation of the UL Listed alarm panel must be in accordance with the manufacturer s written UL Compliance rules for the type of UL certificate to be ac...

Страница 34: ...m panel s DACT and the Model 4550 CB unit must be used for alarm communications to the central monitoring station s UL Listed digital alarm receiver 9 The telephone line connected to the RJ31X jack ca...

Страница 35: ...n to the requirements for additional backup battery power i e 80 hours and shock or vibration sensors In this application the required backup battery is a UL Listed 12VDC 12 0 AH battery Recommended B...

Страница 36: ...no more than 10 attempts 20 Low battery trouble shall be annunciated at the central station 21 The status of each device must be checked every 90 seconds or less 22 Refer to LED Table and wiring diag...

Страница 37: ...d non power limited circuits and all non power limited high voltage wiring must be secured a minimum of 1 4 inch away from all power limited wiring 27 The 4550 CB has two EOLR supervised inputs that r...

Страница 38: ...Ringer Equivalence 0 3 REN Mode Loop start 26 mA typical Phone Line Monitor On Hook voltage 8 50 VDC Off Hook current 10 0 mA Power 400 mW AC Transformer 16 5 V 45VA AC Supply 120VAC 60Hz 430mA Norma...

Страница 39: ...Ripple 20mV Radio Frequencies 850 1900 MHz Avg Current 290 mA Peak Current 2A DC Voltage 3 3 4 2 V D C Sensitivity 109 dB typical Environmental Temperature Range 0 to 49 C Humidity 0 to 85 non conden...

Страница 40: ...49 Zs 000 Alarm generic E140 UA 10 Za BL Burglary Alarm E130 BA 10 Za BU Burglary Restoral R130 BR 12 Zr BU Burglary Tamper E137 TA 10 Zs 011 Burglary Tamper Restoral R137 TR 12 Zs 003 Closing R400 CL...

Страница 41: ...Zr A1 Medical Alarm E100 MA 10 Za EM Medical Restoral R100 MR 12 Zr EM Opening E400 OP 2F Zq OP Panic Alarm E120 PA 10 Za PN Panic Restoral R120 PR 12 Zr PN Phone Fail E350 LT 44 Zs 028 Phone Restora...

Страница 42: ...T DESCRIPTION CONTACT ID EVENT CODE SIA DC 03 EVENT CODE MODEM lle llla lllla2 DMP EVENT CODE Test E602 TX 33 Zs 007 Trouble generic E300 UT 11 Zt BL Trouble Restoral generic R300 UR 12 Zr BL Trouble...

Страница 43: ...DC 03 EVENT CODE MODEM lle llla llla2 ZONE NO REPORTED AC Loss E301 AT 48 239 AC Restoral R301 AR 49 239 Low Battery E302 YT 4B 240 Low Battery Restoral R302 YR 4C 240 Telco Trouble E351 LT 44 241 Te...

Страница 44: ...EVENT CODE SIA DC 03 EVENT CODE MODEM lle llla llla2 ZONE NO REPORTED Watchdog Circuit Trouble E616 YX 11 246 Watchdog Circuit Restoral R616 YZ 12 246 Input 1 Alarm E140 UA 10 247 Input 1 Normal R140...

Страница 45: ...OMMUNICATOR INSTALLATION OPERATION AND PROGRAMMING GUIDE 2013 Uplink Security LLC All rights reserved Uplink is a trademark of Uplink Security LLC GUIDE 00 25580 876 REV A 3330 CUMBERLAND BLVD SUITE 7...

Страница 46: ...1 FOR SALES PRODUCT INFORMATION Uplink 3330 Cumberland Blvd Suite 700 Atlanta GA 30339 1 888 9 UPLINK sales uplink com www uplink com FOR TECHNICAL SUPPORT Please visit our website at www uplink com...

Отзывы: