Electric Combination Boiler User Manual
CARE AND BOILER CLEANING
Regular maintenance is required by expert teams according to the manufacturer's instructions for the
efficient operation of your system.
Regular checks:
The water level must always be checked. The pressure gauge must be marked after the first
filling of the system. When the water is cold, the water pressure level should be checked. If
the water level or pressure has fallen below the static pressure or system setting, water should
be added to the system (when the appliance is cold). To protect the system and the device
from corrosion, the water to be fed into the system must be softened according to local
settings.
Check the electrical cables for wear, peeling, or a problem due to external influences.
Cleaning the appliance:
The outer skin panels of the device can be cleaned as required.
Maintenance:
Contracted service of the system before each working season; we strongly recommend that you call
our authorized service to check the device, installation, electrical connections. Do not do any
maintenance work without the help of an expert. At least once a year the authorized service must be
checked and maintained. In electrical devices, loosening of connection points can occur over time. In
order to avoid any problems, it is appropriate to carry out the aforementioned checks.
ASSEMBLY
The boiler must be placed in a protected place against
freezing. Precautions should be taken to prevent water
from freezing, especially if it is not used for a long time in
cold areas.
If the mains water is higher than 6 bar, pressure regulator
must be placed in the domestic water inlet. If the water
pressure of the domestic water is less than 0.8 bar, the
pressure will not be sufficient.
It is compulsory to place a dirt trap (filter) at the entrance
of the combi boiler from the radiators. The strainer will
prolong the life of the combi boiler because it will hold
possible particles that may come into the combi parts
from the radiators.