uniwatt UHC Скачать руководство пользователя страница 5

INSUHC0116

5

ELECTRICAL CONNECTION & OPERATION

WITH A BUILT-IN ELECTRONIC THERMOSTAT

HOW TO SET THE TEMPERATURE

You can change the temperature by increasing (top button) or decreasing (bottom button) the set point. The temperature set point will increase 

or decrease by increments of 0.5 °C (or 1 °F) each time you press down a button. If you hold down the button, the temperature will quickly scroll 

through, allowing a faster and more efficient setting. Once the temperature is set, release the button.

PRECISE ELECTRONIC CONTROL

A chrono-proportional electronic thermostat controls this unit with a high degree of accuracy in order to minimize temperature differences and 

increase your comfort level. It allows very stable temperature and ensures uniform comfort. It also keeps the casing at a low temperature, making 

it more secure.
The chrono-proportional electronic thermostat entirely regulates the unit by increasing or decreasing the heating cycle percentage according to 

the selected temperature. Please note that the unit becomes warmer if the heating demand is higher and that it remains mildly warm when the 

demand is lower.

N.B. If the unit is set on high or if it is not functioning at all, the temperature gage of the thermostat sensor cannot 

take  a  precise  reading.  However,  the  reading  becomes  extremely  precise  once  the  heating  level  has  stabilized. 

Therefore, uniform convection increases the precision of the thermostat.

In order to obtain a precise and optimal ambient temperature reading, the unit must operate on a regular basis, i.e. without significant temperature 

variation for at least an hour. (This amount of time increases if a temperature change of more than 4 degrees is requested. Add approximately 15 

minutes for every degree above 4).

ELECTRONIC WALL THERMOSTAT CONTROL

An electronic wall thermostat equipped with a proportional tension variation that maintains a precise temperature is preferable thus increasing your comfort level.

OPERATION

Unit

Electric 

box

Connector (marette)

Green wire

L1

L2

THIS PRODUCT MUST BE CONNECTED BY 

A QUALIFIED ELECTRICIAN, ACCORDING 

TO THE ELECTRICAL AND BUILDING CODES 

EFFECTIVE IN YOUR REGION.

This unit must be connected by a certified electrician. Connect the 

bare wire (ground) to the green wire. Connect wires from the electric 

box to the unit’s supply leads. 

ELECTRICAL CONNECTION

STANDARD MODELS

(FIXED CONNECTION)

MODELS WITH 120 V PLUG 

(RESIDENTIAL OUTLET)

THIS UNIT IS EQUIPPED WITH A THREE-WIRE GROUNDING 

TYPE AC PLUG:

 - For safety reasons, the plug can only be inserted into an outlet with 

grounding. If you are unable to insert the plug into the outlet, con-

tact your electrician to have a suitable receptacle installed. Do not 

condemn the ground prong of the plug.

 

-

This heater must be plugged into a dedicated 120 V circuit. The 

addition of other electrical appliances on this circuit may trip 

the circuit breaker.

 - Plug the cord of the heater directly into the wall outlet (do not use 

an extension cord).

Содержание UHC

Страница 1: ...LIST INCLUDED UHC S Y S T È M E Q U A L I T É C ERTIFIÉ REGISTERED Q U A L I T Y S Y S T E M UNIWATT is a line of products manufactured by STELPRO For more information please contact customer service USER S GUIDE This unit complies with CSA standards ...

Страница 2: ...it produces some temporary odours and whitish smoke Because this unit is hot when in use it may pose risks even in normal operation Therefore be careful and responsible when using it To avoid burns do not let bare skin touch hot surfaces Let the unit cool down for a few minutes before handling it it stays warm for some time after shut down Extreme caution is necessary when any heater is used by or...

Страница 3: ...3 3 UHC1502W UHC1502WCW 1500 240 727 28 5 8 7 1 15 7 UHC2002W UHC2002WCW 2000 240 889 35 8 6 18 9 FRONT 17 9 16 446mm 4 102mm MIN 1 1 4 32mm 4 101mm 1 5 16 34mm 10 7 8 277mm 2 7 16 62mm 3 4 19mm O 7 8 22mm KO h h SIDE TOP 5 8 16mm LENGTH TECHNICAL DRAWINGS TECHNICAL DRAWINGS AND SPECIFICATIONS BUILT IN THERMOSTAT POWER VOLTAGE LENGTH WEIGHT CODE WATTS VOLTS MM IN KG LB UHC1501PW 1500 120 727 28 5 ...

Страница 4: ...uction INSTALLATION OF THE WALL RACK 1 Remove the unit from the wall rack s hooks 2 Put the bracket on the floor on the wall where the appliance is installed and draw a temporary line under the horizontal line of the bracket using a pencil FIG 1 3 Align bottom of wall bracket with the temporary line drawn in the previous step FIG 2 4 Make marks with a pencil to identify the four areas where you wi...

Страница 5: ...rm convection increases the precision of the thermostat In order to obtain a precise and optimal ambient temperature reading the unit must operate on a regular basis i e without significant temperature variation for at least an hour This amount of time increases if a temperature change of more than 4 degrees is requested Add approximately 15 minutes for every degree above 4 ELECTRONIC WALL THERMOS...

Страница 6: ...ns The unit runs continuously Defective thermostat or wrong thermostat setting The enclosure is extremely hot Defective thermal protection Blocked air vents The desired room temperature cannot be reached One or more defective elements Defective thermostat or wrong thermosat setting Voltage lower than indicated on the nameplate Heat losses greater than the unit s capacity Overheating Defective ther...

Страница 7: ...0500 10 1 ELEMENT 500 W 120 V 3 EUC0500 10 3 ELEMENT 500 W 174 V 3 EUC0500 10 5 ELEMENT 500 W 240 V 3 EUC0500 10 6 ELEMENT 500 W 300 V REF PART DESCRIPTION 3 EUC0500 10 7 ELEMENT 500 W 139 V 3 EUC0500 10 8 ELEMENT 500 W 104 V 3 EUC0750 15 1 ELEMENT 750 W 120 V 3 EUC0750 15 3 ELEMENT 750 W 174 V 3 EUC0750 15 5 ELEMENT 750 W 240 V 3 EUC0750 15 6 ELEMENT 750 W 300 V 3 EUC0750 15 7 ELEMENT 750 W 139 V...

Страница 8: ...any liability for property or personal injury damages penalties special or punitive damages damages for lost profits loss of use of equipment cost of capital cost of substitute products facilities or services shutdowns slowdowns or for other types of economic loss or for claims of a dealer s customers or any third party for such damages Stelpro specifically disclaims all consequential incidental a...