WARNING

Before installing and operating this product, the user and/or installer must read, understand and follow these instructions and 

keep them handy for future reference. If these instructions are not followed, the warranty will be considered null and void and the 

manufacturer deems no further responsibility for this product.

This product must be installed by a qualified person and connected by a 

certified electrician

, according to the 

electrical and 

building codes

 effective in your region.

The following instructions must be adhered to in order to avoid personal injuries or property damages, serious injuries and potentially 

fatal electric shocks.

Protect the heating unit with the appropriate circuit breaker or fuse, in accordance with the nameplate.
Make sure the line voltage (volt) is consistent with that indicated on the unit’s nameplate. 
Switch off the power at the circuit breaker/fuse before installing, repairing and cleaning the unit.
Make sure the unit is appropriate for the intended use (if needed, refer to the product catalog or a representative). Use this heater only as described in this 

manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons. Do not use outdoors.

RECOMMENDED HEATING CAPACITY:

 

1.25 W/cubic foot (0.03 m³)

It corresponds to 

10 W/square foot (0.09 m²)

 based on a standard ceiling height of 

8 feet (2.44 m)

. The recommended capacity is usually sufficient 

for normal heating needs. Please note that the insulation quality of walls and windows are some of the factors that influence heat losses, which modify the 

required capacity to heat a room. If needed, refer to a specialist who will be able to calculate these heat losses and optimize the required capacity or consult 

the “Online heating calculation” section of the Stelpro website (residential buildings). To heat a large room and to increase your comfort, it is recommended 

to install several units instead of one. For example, 2 X 1000 W rather than 1 X 2000 W.

Do not install the unit where objects or pieces of furniture could be heat damaged.
If the unit’s capacity is insufficient for the size of the room, it will be in operation continuously, and may become defective earlier and turn yellow.

Respect distances and positions

 indicated in the installation section.

If the installer or user modifies the unit, they will be held responsible for any damage resulting from this modification, and the CSA certification could be void.
This unit must not come into contact with a water source and must be protected from splashes (e.g. a wet mop). Do not use it if any part has been immersed. 

Moreover, do not turn it on or off when standing in water or if your hands are wet.
When mounting the unit, make sure that the anchorage used can support the total weight of the unit with the mounting brackets.
When cutting or drilling into a wall, do not damage electrical wiring and other hidden utilities.

When starting up the unit for the first time or after a long period, it is normal that it produces some temporary odours and whitish smoke.

Because this unit is hot when in use, it may pose risks even in normal operation. Therefore, be careful and responsible when using it. To avoid burns, do not 

let bare skin touch hot surfaces. Let the unit cool down for a few minutes before handling it (it stays warm for some time after shut-down). Extreme caution is 

necessary when any heater is used by or near children or invalids and whenever the heater is left operating and unattended.
The bottom of this unit must be installed at least 

4 inches (10.2 cm)

 from the floor and

 6 inches (15.2 cm)

 from any adjacent surfaces. However, make sure 

objects or pieces of furniture such as, but not limited to, blankets, towels, beds, laundry baskets, clothing, papers, etc. do not come into contact with the unit and 

keep them at least 

12 inches (30.5 cm)

 from the unit since they are more flammable than walls and floors. Failure to comply with this warning could lead to a 

fire. Some materials are more heat-sensitive than others, so make sure those near the unit can withstand heat.
Do not install on a wall behind a door.

Never block air vents 

(with objects or other items).

 

You risk damaging the heater and the obstruction could lead to electric shock or overheating, which 

could result in a fire. 
Do not insert or allow foreign objects to enter any air vent as this may cause electric shocks, a fire or damages to the unit.
This unit has hot and arcing or sparking parts inside. It is not designed to be used or stored in wet areas or areas containing flammable liquids, combustible 

materials or corrosive, abrasive, chemical, explosive and flammable substances such as, but not limited to, gasoline, paint, chlorine, sawdust and cleaning 

products.
Some areas are dustier than others. Thus, it is the user’s responsibility to evaluate if the unit must be cleaned based on the amount of dirt accumulated on 

and inside air vents. Accumulated dirt can lead to a component malfunction or give a yellowish colour to unit. Failure to install and maintain unit in accordance 

with these instructions poses a fire hasard.

Thermal protection activation indicates that the unit has been subjected to abnormal operating conditions. If the thermal protection remains activated or 

activates and deactivates repeatedly, it is recommended that a qualified electrician or a certified repair centre examine the unit in order to make sure it is not 

damaged. (Refer to the limited warranty.)
Before unplugging the unit, all controls must be in the “OFF” position and the current from the main breaker panel should be cut. (The general switch may be 

used also, if included.)

If the unit is damaged or defective, discontinue use, cut off power supply at circuit breaker and contact a certified electrician or certified repair centre. (Refer 

to the limited warranty)

Note: 

When a part of the product specification must be changed to improve operability or other functions, priority is given to the product specification itself.  In such 

instances, the instruction manual may not entirely match all the functions of the actual product. Therefore, the actual product and packaging, as well as the name 

and illustration, may differ from the manual. 

IMPORTANT INSTRUCTIONS

SAVE THESE INSTRUCTIONS

Содержание UHC

Страница 1: ...LIST INCLUDED UHC S Y S T È M E Q U A L I T É C ERTIFIÉ REGISTERED Q U A L I T Y S Y S T E M UNIWATT is a line of products manufactured by STELPRO For more information please contact customer service USER S GUIDE This unit complies with CSA standards ...

Страница 2: ...it produces some temporary odours and whitish smoke Because this unit is hot when in use it may pose risks even in normal operation Therefore be careful and responsible when using it To avoid burns do not let bare skin touch hot surfaces Let the unit cool down for a few minutes before handling it it stays warm for some time after shut down Extreme caution is necessary when any heater is used by or...

Страница 3: ...3 3 UHC1502W UHC1502WCW 1500 240 727 28 5 8 7 1 15 7 UHC2002W UHC2002WCW 2000 240 889 35 8 6 18 9 FRONT 17 9 16 446mm 4 102mm MIN 1 1 4 32mm 4 101mm 1 5 16 34mm 10 7 8 277mm 2 7 16 62mm 3 4 19mm O 7 8 22mm KO h h SIDE TOP 5 8 16mm LENGTH TECHNICAL DRAWINGS TECHNICAL DRAWINGS AND SPECIFICATIONS BUILT IN THERMOSTAT POWER VOLTAGE LENGTH WEIGHT CODE WATTS VOLTS MM IN KG LB UHC1501PW 1500 120 727 28 5 ...

Страница 4: ...uction INSTALLATION OF THE WALL RACK 1 Remove the unit from the wall rack s hooks 2 Put the bracket on the floor on the wall where the appliance is installed and draw a temporary line under the horizontal line of the bracket using a pencil FIG 1 3 Align bottom of wall bracket with the temporary line drawn in the previous step FIG 2 4 Make marks with a pencil to identify the four areas where you wi...

Страница 5: ...rm convection increases the precision of the thermostat In order to obtain a precise and optimal ambient temperature reading the unit must operate on a regular basis i e without significant temperature variation for at least an hour This amount of time increases if a temperature change of more than 4 degrees is requested Add approximately 15 minutes for every degree above 4 ELECTRONIC WALL THERMOS...

Страница 6: ...ns The unit runs continuously Defective thermostat or wrong thermostat setting The enclosure is extremely hot Defective thermal protection Blocked air vents The desired room temperature cannot be reached One or more defective elements Defective thermostat or wrong thermosat setting Voltage lower than indicated on the nameplate Heat losses greater than the unit s capacity Overheating Defective ther...

Страница 7: ...0500 10 1 ELEMENT 500 W 120 V 3 EUC0500 10 3 ELEMENT 500 W 174 V 3 EUC0500 10 5 ELEMENT 500 W 240 V 3 EUC0500 10 6 ELEMENT 500 W 300 V REF PART DESCRIPTION 3 EUC0500 10 7 ELEMENT 500 W 139 V 3 EUC0500 10 8 ELEMENT 500 W 104 V 3 EUC0750 15 1 ELEMENT 750 W 120 V 3 EUC0750 15 3 ELEMENT 750 W 174 V 3 EUC0750 15 5 ELEMENT 750 W 240 V 3 EUC0750 15 6 ELEMENT 750 W 300 V 3 EUC0750 15 7 ELEMENT 750 W 139 V...

Страница 8: ...any liability for property or personal injury damages penalties special or punitive damages damages for lost profits loss of use of equipment cost of capital cost of substitute products facilities or services shutdowns slowdowns or for other types of economic loss or for claims of a dealer s customers or any third party for such damages Stelpro specifically disclaims all consequential incidental a...