uniwatt UHC Скачать руководство пользователя страница 4

INSUHC0116

4

INSTALLATION

HANGING THE UNIT ON THE WALL BRACKET

1. Insert the lower hooks of the wall bracket in the device. (FIG. 3)
2. Tilt the top of the unit and snap it. (FIG. 4)
3. Push the unit to secure it. (FIG. 5)
4. 

The unit must be mounted at least 4 inches (10.2 cm) from the floor. 

(FIG. 6)

REMOVING THE UNIT FROM THE WALL RACK

1. Using a screwdriver, press on each clip. (FIG. 7)
2. Pull the upper part of the unit toward you to disengage the hooks.
3. Pull the unit off the lower hooks

CUT OFF POWER SUPPLY AT CIRCUIT BREAKER/FUSE BEFORE PROCEEDING TO THE

INSTALLATION.

 -

The unit should be installed at least 4 in (10.2 cm) from the floor and 6 in (15 cm) from adjacent walls.

 - Before operating the unit, make sure that both the air inlet (bottom) and air outlet (front) are free from obstruction.

INSTALLATION OF THE WALL RACK

1. Remove the unit from the wall rack’s hooks.
2. 

Put the bracket on the floor, on the wall where the appliance is installed and draw a temporary line under the horizontal line of the bracket 

using a pencil. (FIG. 1)

3. Align bottom of wall bracket with the temporary line drawn in the previous step. (FIG. 2)
4. Make marks with a pencil to identify the four areas where you will screw the bracket.
5. Secure the bracket to the wall making sure it is level. When drilling the wall, make sure not to damage electrical wiring and other hidden 

utilities.

N.B. The wall where you install the device must be straight so that the bracket is perfectly level, without any 

pressure. It is very important to follow this directive to prevent damaging the bracket during the installation. This 

could cause malfunction of the interlock system.

INSTALLATION

ç

FIG. 3

ç

FIG. 4

ç

FIG. 5

FIG. 7

FIG. 2

LINE DRAWN IN PENCIL

DRAW LINE IN PENCIL 

HERE

FLOOR

FLOOR

FIG. 1

FIG. 6

Содержание UHC

Страница 1: ...LIST INCLUDED UHC S Y S T È M E Q U A L I T É C ERTIFIÉ REGISTERED Q U A L I T Y S Y S T E M UNIWATT is a line of products manufactured by STELPRO For more information please contact customer service USER S GUIDE This unit complies with CSA standards ...

Страница 2: ...it produces some temporary odours and whitish smoke Because this unit is hot when in use it may pose risks even in normal operation Therefore be careful and responsible when using it To avoid burns do not let bare skin touch hot surfaces Let the unit cool down for a few minutes before handling it it stays warm for some time after shut down Extreme caution is necessary when any heater is used by or...

Страница 3: ...3 3 UHC1502W UHC1502WCW 1500 240 727 28 5 8 7 1 15 7 UHC2002W UHC2002WCW 2000 240 889 35 8 6 18 9 FRONT 17 9 16 446mm 4 102mm MIN 1 1 4 32mm 4 101mm 1 5 16 34mm 10 7 8 277mm 2 7 16 62mm 3 4 19mm O 7 8 22mm KO h h SIDE TOP 5 8 16mm LENGTH TECHNICAL DRAWINGS TECHNICAL DRAWINGS AND SPECIFICATIONS BUILT IN THERMOSTAT POWER VOLTAGE LENGTH WEIGHT CODE WATTS VOLTS MM IN KG LB UHC1501PW 1500 120 727 28 5 ...

Страница 4: ...uction INSTALLATION OF THE WALL RACK 1 Remove the unit from the wall rack s hooks 2 Put the bracket on the floor on the wall where the appliance is installed and draw a temporary line under the horizontal line of the bracket using a pencil FIG 1 3 Align bottom of wall bracket with the temporary line drawn in the previous step FIG 2 4 Make marks with a pencil to identify the four areas where you wi...

Страница 5: ...rm convection increases the precision of the thermostat In order to obtain a precise and optimal ambient temperature reading the unit must operate on a regular basis i e without significant temperature variation for at least an hour This amount of time increases if a temperature change of more than 4 degrees is requested Add approximately 15 minutes for every degree above 4 ELECTRONIC WALL THERMOS...

Страница 6: ...ns The unit runs continuously Defective thermostat or wrong thermostat setting The enclosure is extremely hot Defective thermal protection Blocked air vents The desired room temperature cannot be reached One or more defective elements Defective thermostat or wrong thermosat setting Voltage lower than indicated on the nameplate Heat losses greater than the unit s capacity Overheating Defective ther...

Страница 7: ...0500 10 1 ELEMENT 500 W 120 V 3 EUC0500 10 3 ELEMENT 500 W 174 V 3 EUC0500 10 5 ELEMENT 500 W 240 V 3 EUC0500 10 6 ELEMENT 500 W 300 V REF PART DESCRIPTION 3 EUC0500 10 7 ELEMENT 500 W 139 V 3 EUC0500 10 8 ELEMENT 500 W 104 V 3 EUC0750 15 1 ELEMENT 750 W 120 V 3 EUC0750 15 3 ELEMENT 750 W 174 V 3 EUC0750 15 5 ELEMENT 750 W 240 V 3 EUC0750 15 6 ELEMENT 750 W 300 V 3 EUC0750 15 7 ELEMENT 750 W 139 V...

Страница 8: ...any liability for property or personal injury damages penalties special or punitive damages damages for lost profits loss of use of equipment cost of capital cost of substitute products facilities or services shutdowns slowdowns or for other types of economic loss or for claims of a dealer s customers or any third party for such damages Stelpro specifically disclaims all consequential incidental a...

Отзывы: