background image

Introduction

This manual contains instructions for the installation, operation, care, and sharpening

of the 4612 economy slicer. It is recommended that all operators familiarize

themselves with this manual prior to operating the slicer.

Inspection:

All UNIVEX slicers are inspected and tested at the factory; however, they should be

inspected carefully by the person making the installation for loose, damaged or broken parts. Any 

damages, imperfections or shortages should be reported to the dealer or UNIVEX and shipping 

carrier.

Warning

: After slicer has been inspected, wash slicer completely with warm water and

mild soap. For safety, follow the cleaning instructions on Pages 6 - 7.

Installation:

The most efficient installation of your slicer will depend upon the layout of your kitchen. Locate 

your slicer where it will save steps for the operator and be sure to provide sufficient clearance 

around it for ease of maintenance and cleaning, as well as for efficient and safe use. Ensure the

surface is level and flat before installation. Slicer should be operated on a sturdy bench or table 

with the height determined to suit the operator. It is most important that the forearm of the operator 

be at the proper level for ease and safety of operation, as well as for maximum production. This 

height is considered optimum when the carriage handle (Overview [10]) of the slicer is at 

approximately the height of the operator's elbow when standing.

Important:

Warning/Caution:

 Before making electrical connections, CHECK the specifications on the 

nameplate to make sure that they agree with those on your electrical service. A grounding type 

three-terminal plug is provided for safety. If you do not have a mating receptacle, have a qualified 

electrician provide one with grounding provisions in accordance with local safety codes.

IMPORTANT SAFETY WARNINGS:

It is a violation of United States Department of Labor regulations to permit operation of the slicer

by any person under the age of 18 years.

Warning:

 

The slicer knife is extremely sharp! Never touch the knife, always keep hands and fingers clear of 

the knife. Never run slicer without the guard and all other parts in place and securely fastened. 

Take extra care to avoid accidents by keeping the knife guard ON at all times. When the machine is

not in use, the slice adjustment knob should be turned fully back to the closed position (beyond "0")

so that the knife edge is not exposed

Observe the cleaning instructions on Pages 6 - 7 for best results and for safety. Also remember to 

always turn off the slicer and disconnect the electrical supply cord before cleaning. When slicing, 

always move the carriage using only the carriage arm handle (Overview [10]). Do not 

hold or push the carriage from any other place.

Page 4

Содержание 4612

Страница 1: ...cer Operator s Manual 05 2012 ED1 Persons under the age of 18 are not permitted to operate or have accessibility to operate this equipment per U S Dept Of Labor employment standards administration fact sheet No ESA91 3 ...

Страница 2: ...L BE INVLOVED WITH YOUR NEW UNIVEX SLICER MUST READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE ATTEMPTING TO OPERATE THIS SLICER WE APPRECIATE YOUR COOPERATION AND YOUR BUSINESS SHOULD THERE BE A QUESTION OR IF WE CAN BE OF FURTHER ASSISTANCE PLEASE CALL US 1 800 258 6358 ATTENTION Page 1 ...

Страница 3: ...s p 5 6 Cleaning Instructions p 6 7 7 Sanitizing Instructions p 8 9 Lubrication Instructions p 10 10 Inspection of Seals p 11 11 Slicer Wiring Diagram p 12 12 Warranty Information p 13 a Inspection b Installation c Important Safety Warnings a Start Stop Switch b Slice Adjustment c Positive Hold Carriage d Protective Guard 8 Sharpening Instructions p 9 Page 2 ...

Страница 4: ...On Off Switch and Indicator Light 2 Fence 3 Last Slice Device 4 Sharpener Assembly 5 Protective Guard 6 Knife Guard 7 Carriage 8 Carriage Arm 9 Carriage Arm Handle 10 Carriage Arm Knob 11 Slice Adjustment Knob 1 2 3 4 5 6 7 8 9 10 11 Page 3 ...

Страница 5: ...tion This height is considered optimum when the carriage handle Overview 10 of the slicer is at approximately the height of the operator s elbow when standing Important Warning Caution Before making electrical connections CHECK the specifications on the nameplate to make sure that they agree with those on your electrical service A grounding type three terminal plug is provided for safety If you do...

Страница 6: ...s fully closed position beyond 0 so that the knife edge is not exposed POSITIVE HOLD CARRIAGE Caution A last slice gravity feed grip Overview 3 is provided which can be locked out of the way when not required Do not use this last slice device to work the carriage back and forth Use only the carriage arm handle Overview 10 Always make sure the carriage is positively secured to the slicer by checkin...

Страница 7: ...nter clockwise from carriage and through Last Slice Device Figure 1 1 to remove and set aside b Carriage Arm Handle Loosen and remove the black handle Figure 1 4 and set aside c Carriage Arm Loosen the Carriage Arm Knob Figure 1 6 and set aside for cleaning Pull straight upwards on the Carriage and Arm Figure 1 5 and set the Carriage Assembly aside d Sharpener Assembly Unscrew sharpener locking pi...

Страница 8: ... mild detergent 5 Remove the Knife Scraper shown in Figure 6 by unscrewing the 2 thumb screws Figure 7 shows the scraper removed Set aside and hand wash the scraper Wash the front and rear of the Knife Figure 5 2 using extreme CAUTION around the blade Clean around the Knife s edge as shown in Figure 8 with warm water and a mild detergent applied to a soft cloth 6 Wash the Slicer Body Figure 5 3 wi...

Страница 9: ...Section 4 501 114 Manual and Mechanical Warewashing Equipment Chemical Sanitation Temperature pH Concentration and Hardness of the FDA Food Code Chlorine Sanitizer Solution A chlorine sanitizer solution shall have a minimum temperature based on the concentration and pH of the solution listed in the following chart taken from section 4 501 114 of the FDA Food Code Minimum Concentration mg L 25 50 1...

Страница 10: ...l Dial Figure 1 12 to beyond 0 This will ensure that the blade edge is not exposed to the operator 4 Move the carriage all the way to the start position closest to the operator 5 Loosen the sharpener locking pin Figure 2 1 then lift and rotate the sharpener 180 Lower the sharpener so that the blade is between the 2 stones and resecure with the sharpener locking pin 6 Turn the slicer on The sharpen...

Страница 11: ...s as well as for excessive wear and looseness of various parts Be sure to check all handles and knobs for tightness Never use any type of vegatable cooking spray or oil as lubrication as this will cause damage to your slicer Lubrication Instructions A Clean and apply mineral oil weekly B Apply Petro Gel 4400408 as often as required to maintain a light film Remove the 3 bottom cover screws and 4 ru...

Страница 12: ...ry to remove the slicer from service and contact an authorized service agency or Univex Full thorough inspections should be conducted not exceeding 6 month periods and is recommended to be performed by an authorized service agency However as the regular operator of the machine seals should be reviewed during normal daily cleaning and reported upon if found to be worn Refer to the below figure 13 f...

Страница 13: ...Power In Power In Circut Breaker Switch Switch Motor Ground Ground Capacitor Motor Capacitor 4612 Wiring Diagram Standard Canada Only Page 12 ...

Страница 14: ...hours of 8 00 a m and 5 00 p m local time Monday through Friday Univex will not cover overtime charges of any kind Please call the Univex Warranty Service Department at 800 258 6358 to report any warranty claims before arranging repair or attempting to return the unit to Univex Corporation Damages incurred in transit or incurred because of installation error accident alteration or misuse are not c...

Отзывы: