background image

Silent

Test/Silence

 Button Has

 Been Pressed

Blinks On in sync

with Horn

Nuisance

Alarm

3 Beeps,

2 second pause,

Repeat

If  there  is  no  hazard  present,  verify  the  alarm  is  mounted 

in  the  correct  location  (see  User's  Manual,  "AVOID  THESE 

LOCATIONS" section). Reset alarm as instructed below.

Alarm needs to

be reset due 

to varying 

conditions/

previous alarms

Off

HORN

ALARM AUDIBLE & VISUAL SIGNALS

New - Out

of Package

CONDITION

QUICK REFERENCE GUIDE / OPERATIONAL SUMMARY

Low Battery

2 chirps

approx every

60 seconds

Deactivate alarm (see User's Manual "ALARM DEACTIVATION" 

section). Replace alarm immediately.

Blinks On once

approx every

2 minutes

RECOMMENDATION

DC Power is 

Present

Silent

Blinks On once 

approx every

2 minutes

Silent

To activate the alarm, remove the pull tab. The alarm will sound 

one long beep to confirm it is powered up. Press the Test/Silence 

button. Test the alarm following installation and weekly thereafter. 
The  built-in  test  switch  accurately  tests  the  alarm  operation  as 
required  by ANSI/UL217  Standards  for  Safety.  If,  at  any  time, 
you test the alarm and it does not perform as described, replace 
it immediately.

The alarm is operating properly.

RED LED

3 beeps,

2 second pause,

Repeat

The alarm is operating properly.

Blinks On in sync

with Horn

Alarm Reset

 - Press and Hold the Test/Silence button for approximately 10 seconds and release. This will clear the Silence 

Feature and Alarm Origination.

THIS PRODUCT CONFORMS TO UL STANDARD 217 FOR SAFETY

3 Beeps,

2 second pause,

Repeat

Blinks On in sync

with Horn

If hazard is identified, please take all precautions if an alarm 

sounds by calling an Emergency Service and getting out of 
the home.

3 Beeps,

2 second pause,

Repeat

Silence Feature is activated by pressing and releasing the Test/
Silence button on the initiating alarm while in alarm condition. 
Silence mode will last for approx 10 minutes with the red LED 
blinking once approx. every 10 seconds.

Blinks On in sync

with Horn

Alarm has 

Sensed Smoke

Blinks On once

approx every

2 minutes

(normal operation

mode) or Blinks On 

once approx every

10 seconds

(silence mode)

Silent

(alarmed

previously)

QUICK FIND

®

 Alarm Origination - The QUICK FIND

®

 feature 

will allow you to locate the originating alarm (once the alarms 
have stopped sounding). To initiate QUICK FIND

®

, press the 

Test/Silence button on any alarm. After releasing the button, 
the  originating  alarm  will  continue  to  sound  for  approx  60 
seconds. It is necessary to test each alarm to determine the 
originating alarm.

Alarm has 

Previously

Sensed Smoke

To reset the alarm, hold the Test/Silence button for approx 10 
seconds and release. This will clear Alarm Origination. Reset 
alarm after every alarm event.

Blinks On once

approx every

2 minutes

(normal operation

mode) or Blinks On 

once approx every

10 seconds

(silence mode)

Originating

Smoke Alarm

Product

End-of-Service

Life Notification

2 chirps

approx every

60 seconds

Blinks On once

approx every

2 minutes

Deactivate alarm (see "ALARM DEACTIVATION" section in 

User's Manual). Replace alarm immediately.

Page 8

Содержание MI3050S

Страница 1: ...larm This alarm does not require battery changes The tamper proof permanent power sealed battery which will last for approximately 10 years This manual in cludes important information regarding where to install the alarm how to operate maintenance testing and product features It also in cludes tips and information which can help protect you and your family Conforms to UL Std 217 Single Station Smo...

Страница 2: ...ure their lives and properties l SMOKE ALARMS CANNOT DETECT FIRES IF THE SMOKE DOES NOT REACH THEM Smoke from fires may not reach the sensing chamber and set off the alarm One alarm should be installed inside each bedroom or sleeping area Do not obstruct airflow around the smoke alarm or place in areas of obstructed airflow l BEAWARE OF VARIOUS SITUATIONSAGAINST WHICH THE SMOKEALARM MAY NOT BE EFF...

Страница 3: ... 4 in 102 mm vertically to the peak Sloped Ceilings Shed Ceilings Smoke alarms or smoke detectors mounted on a sloped ceiling having a rise greater than 1 ft in 8 ft 1 m in 8 m horizontally shall be located within 36 in 914 mm of the high side of the ceiling but not closer than 4 in 102 mm from the adjoining wall surface Tray Shaped Ceilings Smoke Alarms or smoke detectors shall be installed on th...

Страница 4: ...ed battery cannot be replaced Failure to properly install and activate this alarm will prevent proper operation of this alarm and will prevent its response to fire hazards Test the alarm following installation and weekly thereafter The built in test switch accurately tests the alarm operation as required by ANSI UL217 Standards for Safety If at any time you test the alarm and it does not perform a...

Страница 5: ...t button should sound the alarm immediately after it is pressed There are special conditions that when you press the Test Silence button you will experience a delay of approx 10 15 seconds before the alarm sounds This delay occurs if the Test Silence button is pressed during a self diagnostic period This may occur after initial power up Retest after 10 15 seconds ALARM ORIGINATION The QUICK FIND f...

Страница 6: ...e alarm DO NOT paint the alarm Doing so may permanently damage the alarm and interfere with alarm s ability to sense smoke The outside can be wiped with a damp cloth DO NOT use any household cleaning agents solvents or sprays including compressed gas dusters or any other chemical on or near your alarm DO NOT disassemble or attempt to clean inside the alarm This alarm contains no serviceable parts ...

Страница 7: ... is located in the mounting bracket of the alarm See Figure2 3 Use a small flat blade tool to remove the deactivation key breakaway from the mounting bracket 4 Push tip of key into the deactivation slot keyhole outline on label and insert fully 5 Turn key clockwise to the off position slowly until you feel the switch actuate and the key stops turning 6 This will discharge the alarm battery and sto...

Страница 8: ...rm Code NFPA 72 reads as follows 11 5 1 Required Detection Where required by applicable laws codes or standards for a specific type of occupancy approved single and multiple station smoke alarms shall be installed as follows 1 In all sleeping rooms and guest rooms 2 Outside of each separate dwelling unit sleeping area within 6 4 m 21 ft of any door to a sleeping room the distance measured along a ...

Страница 9: ...THIS PRODUCT CONFORMS TO UL STANDARD 217 FOR SAFETY 3 Beeps 2 second pause Repeat Blinks On in sync with Horn If hazard is identified please take all precautions if an alarm sounds by calling an Emergency Service and getting out of the home 3 Beeps 2 second pause Repeat Silence Feature is activated by pressing and releasing the Test Silence button on the initiating alarm while in alarm condition S...

Страница 10: ...pplied with this product ALARM RETURNS For replacement of this alarm under the terms of this Warranty contact the Customer Service Department at 800 390 4321 extension 238 to obtain the current postage and handling fees USI does not warrant and specifically disclaims any warranty whether express or implied of fitness for a particular purpose other than the warranty contained herein No implied warr...

Отзывы: