DEVELOP AND PRACTICE A PLAN OF ESCAPE

BASICS OF ESCAPE PLAN

o  Make a floor plan indicating all doors and windows and at least two escape routes from each 

room. Second story windows may need a rope or chain ladder.

o  Have a family meeting and discuss your escape plan, showing everyone what to do in case of 

fire.

o  Determine a place outside your home where all of you can meet if a fire occurs.

o  Familiarize everyone with the sound of the smoke alarm and train them to leave your home 

when they hear the sound.

o  Identify children's bedrooms with red stickers placed in the upper left corner of the windows. 

They are available from your local fire department.

o  Practice a fire drill at least every six months. Practice allows you to test your plan before an 

emergency. You may not be able to reach your children. It is important they know what to do!

WHAT TO DO WHEN THE ALARM SOUNDS

o  Leave immediately by your plan of escape. Every second counts, so don't waste time getting 

dressed or picking up valuables.

o  In leaving, don't open any inside door without first feeling its surface. If hot, or if you see smoke 

seeping through cracks, 

don't open that door!

   Instead, use your alternate exit. If inside door 

is cool, place your shoulder against it, open it slightly and be ready to slam it shut if heat and 
smoke rush in.

o  Stay close to the floor if air is smoky. Breathe shallowly through a cloth, wet if possible.

o  Once outside, go to your selected meeting place and make sure everyone is there.

o  Call the fire department from your neighbor's home – 

not from yours!

o  Don't return to your home until fire officials say that it is all right to do so.

NATIONAL FIRE PROTECTION ASSOCIATION REQUIRED INFORMATION

For your information, the National Fire Alarm Code, NFPA 72, reads as follows:
"11.5.1  *Required  Detection  -  Where  required  by  applicable  laws,  codes,  or  standards  for  a 

specific type of occupancy, approved single and multiple-station smoke alarms shall be installed 

as follows:
(1) *In all sleeping rooms and guest rooms
(2) *Outside of each separate dwelling unit sleeping area, within 6.4 m (21 ft) of any door to a  
sleeping room, the distance measured along a path of travel
(3) On every level of a dwelling unit, including basements.
(4) On every level of a residential board and care occupancy (small facility), including basements  

and excluding crawl spaces and unfinished attics

(5) *In the living area(s) of a guest suite
(6) In the living area(s) of a residential board and care occupancy"

The equipment should be installed using wiring methods in accordance with the

National Fire Protection Association's Standard 72.

(National Fire Protection Association, Batterymarch Park, Quincy, MA 02269)

CAUTION (AS REQUIRED BY THE CALIFORNIA STATE FIRE MARSHAL)

"Early warning fire detection is best achieved by the installation of fire detection equipment in all 

rooms and areas of the household as follows. A smoke alarm installed in each separate sleeping 
area (in the vicinity of, but outside of the bedrooms), and heat or smoke detectors in the living 
rooms,  dining  rooms,  bedrooms,  kitchens,  hallways,  attics,  furnace  rooms,  closets,  utility  and 
storage rooms, basements and attached garages. 

REPAIRS AND SERVICES

This  smoke  alarms  contains  less  than  1  microcurie  (37  kilobecquerel)  of Americium  241,  a 
radioactive material. 

The distribution of these ionization-type smoke alarms is licensed by 

the U.S. Nuclear Regulatory Commission; the consumer is exempt from any licensing or 
requirements.

 If the smoke alarm is defective in any way, do not tamper with the smoke alarm. 

Return the smoke alarm for servicing. (See warranty for instructions or in-warranty returns.) There 
will be a service charge for repairing out of warranty smoke alarms. 

Содержание MI3050S

Страница 1: ...larm This alarm does not require battery changes The tamper proof permanent power sealed battery which will last for approximately 10 years This manual in cludes important information regarding where to install the alarm how to operate maintenance testing and product features It also in cludes tips and information which can help protect you and your family Conforms to UL Std 217 Single Station Smo...

Страница 2: ...ure their lives and properties l SMOKE ALARMS CANNOT DETECT FIRES IF THE SMOKE DOES NOT REACH THEM Smoke from fires may not reach the sensing chamber and set off the alarm One alarm should be installed inside each bedroom or sleeping area Do not obstruct airflow around the smoke alarm or place in areas of obstructed airflow l BEAWARE OF VARIOUS SITUATIONSAGAINST WHICH THE SMOKEALARM MAY NOT BE EFF...

Страница 3: ... 4 in 102 mm vertically to the peak Sloped Ceilings Shed Ceilings Smoke alarms or smoke detectors mounted on a sloped ceiling having a rise greater than 1 ft in 8 ft 1 m in 8 m horizontally shall be located within 36 in 914 mm of the high side of the ceiling but not closer than 4 in 102 mm from the adjoining wall surface Tray Shaped Ceilings Smoke Alarms or smoke detectors shall be installed on th...

Страница 4: ...ed battery cannot be replaced Failure to properly install and activate this alarm will prevent proper operation of this alarm and will prevent its response to fire hazards Test the alarm following installation and weekly thereafter The built in test switch accurately tests the alarm operation as required by ANSI UL217 Standards for Safety If at any time you test the alarm and it does not perform a...

Страница 5: ...t button should sound the alarm immediately after it is pressed There are special conditions that when you press the Test Silence button you will experience a delay of approx 10 15 seconds before the alarm sounds This delay occurs if the Test Silence button is pressed during a self diagnostic period This may occur after initial power up Retest after 10 15 seconds ALARM ORIGINATION The QUICK FIND f...

Страница 6: ...e alarm DO NOT paint the alarm Doing so may permanently damage the alarm and interfere with alarm s ability to sense smoke The outside can be wiped with a damp cloth DO NOT use any household cleaning agents solvents or sprays including compressed gas dusters or any other chemical on or near your alarm DO NOT disassemble or attempt to clean inside the alarm This alarm contains no serviceable parts ...

Страница 7: ... is located in the mounting bracket of the alarm See Figure2 3 Use a small flat blade tool to remove the deactivation key breakaway from the mounting bracket 4 Push tip of key into the deactivation slot keyhole outline on label and insert fully 5 Turn key clockwise to the off position slowly until you feel the switch actuate and the key stops turning 6 This will discharge the alarm battery and sto...

Страница 8: ...rm Code NFPA 72 reads as follows 11 5 1 Required Detection Where required by applicable laws codes or standards for a specific type of occupancy approved single and multiple station smoke alarms shall be installed as follows 1 In all sleeping rooms and guest rooms 2 Outside of each separate dwelling unit sleeping area within 6 4 m 21 ft of any door to a sleeping room the distance measured along a ...

Страница 9: ...THIS PRODUCT CONFORMS TO UL STANDARD 217 FOR SAFETY 3 Beeps 2 second pause Repeat Blinks On in sync with Horn If hazard is identified please take all precautions if an alarm sounds by calling an Emergency Service and getting out of the home 3 Beeps 2 second pause Repeat Silence Feature is activated by pressing and releasing the Test Silence button on the initiating alarm while in alarm condition S...

Страница 10: ...pplied with this product ALARM RETURNS For replacement of this alarm under the terms of this Warranty contact the Customer Service Department at 800 390 4321 extension 238 to obtain the current postage and handling fees USI does not warrant and specifically disclaims any warranty whether express or implied of fitness for a particular purpose other than the warranty contained herein No implied warr...

Отзывы: