RECOMMENDED LOCATION OF ALARMS

•  Locate the first smoke alarm in the immediate area of the bedrooms. Try to protect the escape 

route as the bedrooms are usually farthest from an exit. If more than one sleeping area exists, 
locate additional smoke alarms in each sleeping area. If a hall is more than 40 feet (12 meters) 
long, install a smoke alarm at each end.

•  Locate additional smoke alarms to protect any stairway as stairways act like chimneys for smoke 

and heat.

•  Locate at least one smoke alarm on every floor level.

•  Locate a smoke alarm in any area where a smoker sleeps or where electrical appliances are 

operated in sleeping areas.

•  Smoke, heat and other combustion products rise to the ceiling and spread horizontally. Mounting 

the smoke alarm on the ceiling in the center of the room places it closest to all points in the room. 
Ceiling mounting is preferred in ordinary residential construction. However, in mobile homes, 
wall mounting on an inside partition is preferred to avoid the thermal barrier that may form at the 
ceiling.

•  When mounting smoke alarm on the ceiling, locate it a minimum of 4" (10cm) from a side wall 

or corner (see Diagram A).

•  When mounting smoke alarm on a wall, if local codes allow, use an inside wall with the top edge of 

the smoke alarm a minimum of 4" (10cm) and a maximum of 12" (30.5cm) below the ceiling/wall 
intersections (See Diagram A).

Page 3

Sloped Ceilings (Peaked Ceilings):

Smoke alarms or smoke detectors mounted on a peaked ceiling shall be located within 36 in. (914 mm) 
horizontally of the peak, but not closer than 4 in. (102 mm) vertically to the peak.

Sloped Ceilings (Shed Ceilings):

Smoke alarms or smoke detectors mounted on a sloped ceiling having a rise greater than 1 ft. in 8 ft. (1 
m in 8 m) horizontally shall be located within 36 in. (914 mm) of the high side of the ceiling, but not closer 
than 4 in. (102 mm) from the adjoining wall surface.

Tray-Shaped Ceilings:

Smoke Alarms or smoke detectors shall be installed on the highest portion of the ceiling or on the sloped 

portion of the ceiling within 12 in. (305 mm) vertically down from the highest point.

Mobile Home Installation:

For  minimum  protection,  smoke  alarms    should  be  installed  in  compliance  with  H.U.D.  Manufactured 
Home  Construction  Safety  Standards,  Title  24  CFR,  Section  3280.208  and  Section  3282.  For  additional 
protection, see Single Story Residence smoke alarm requirements/recommendations for Existing Homes 
and New Construction Homes.

Note: For mobile homes built before 1978, install smoke alarms on inside walls between 4” and 12” from 
the ceiling (older mobile homes have little or no insulation in the ceiling). This is especially important if 
the ceiling is unusually hot or cold.

Install a smoke alarm inside each bedroom and in the hallway outside each separate sleeping area.

Existing Homes:
The NFPA requires a smoke alarm on every level and outside each sleeping area in existing construction. 
An existing household with one level and one sleeping area is required to have one smoke alarm.

New Construction Homes and Manufactured Homes:
The NFPA requires AC-powered, interconnected smoke alarms to be installed inside each bedroom, outside 
each bedroom area, and on every level of the home. They also require a minimum of two AC-powered, 
interconnected smoke alarms in any new construction home.

Содержание MI3050S

Страница 1: ...larm This alarm does not require battery changes The tamper proof permanent power sealed battery which will last for approximately 10 years This manual in cludes important information regarding where to install the alarm how to operate maintenance testing and product features It also in cludes tips and information which can help protect you and your family Conforms to UL Std 217 Single Station Smo...

Страница 2: ...ure their lives and properties l SMOKE ALARMS CANNOT DETECT FIRES IF THE SMOKE DOES NOT REACH THEM Smoke from fires may not reach the sensing chamber and set off the alarm One alarm should be installed inside each bedroom or sleeping area Do not obstruct airflow around the smoke alarm or place in areas of obstructed airflow l BEAWARE OF VARIOUS SITUATIONSAGAINST WHICH THE SMOKEALARM MAY NOT BE EFF...

Страница 3: ... 4 in 102 mm vertically to the peak Sloped Ceilings Shed Ceilings Smoke alarms or smoke detectors mounted on a sloped ceiling having a rise greater than 1 ft in 8 ft 1 m in 8 m horizontally shall be located within 36 in 914 mm of the high side of the ceiling but not closer than 4 in 102 mm from the adjoining wall surface Tray Shaped Ceilings Smoke Alarms or smoke detectors shall be installed on th...

Страница 4: ...ed battery cannot be replaced Failure to properly install and activate this alarm will prevent proper operation of this alarm and will prevent its response to fire hazards Test the alarm following installation and weekly thereafter The built in test switch accurately tests the alarm operation as required by ANSI UL217 Standards for Safety If at any time you test the alarm and it does not perform a...

Страница 5: ...t button should sound the alarm immediately after it is pressed There are special conditions that when you press the Test Silence button you will experience a delay of approx 10 15 seconds before the alarm sounds This delay occurs if the Test Silence button is pressed during a self diagnostic period This may occur after initial power up Retest after 10 15 seconds ALARM ORIGINATION The QUICK FIND f...

Страница 6: ...e alarm DO NOT paint the alarm Doing so may permanently damage the alarm and interfere with alarm s ability to sense smoke The outside can be wiped with a damp cloth DO NOT use any household cleaning agents solvents or sprays including compressed gas dusters or any other chemical on or near your alarm DO NOT disassemble or attempt to clean inside the alarm This alarm contains no serviceable parts ...

Страница 7: ... is located in the mounting bracket of the alarm See Figure2 3 Use a small flat blade tool to remove the deactivation key breakaway from the mounting bracket 4 Push tip of key into the deactivation slot keyhole outline on label and insert fully 5 Turn key clockwise to the off position slowly until you feel the switch actuate and the key stops turning 6 This will discharge the alarm battery and sto...

Страница 8: ...rm Code NFPA 72 reads as follows 11 5 1 Required Detection Where required by applicable laws codes or standards for a specific type of occupancy approved single and multiple station smoke alarms shall be installed as follows 1 In all sleeping rooms and guest rooms 2 Outside of each separate dwelling unit sleeping area within 6 4 m 21 ft of any door to a sleeping room the distance measured along a ...

Страница 9: ...THIS PRODUCT CONFORMS TO UL STANDARD 217 FOR SAFETY 3 Beeps 2 second pause Repeat Blinks On in sync with Horn If hazard is identified please take all precautions if an alarm sounds by calling an Emergency Service and getting out of the home 3 Beeps 2 second pause Repeat Silence Feature is activated by pressing and releasing the Test Silence button on the initiating alarm while in alarm condition S...

Страница 10: ...pplied with this product ALARM RETURNS For replacement of this alarm under the terms of this Warranty contact the Customer Service Department at 800 390 4321 extension 238 to obtain the current postage and handling fees USI does not warrant and specifically disclaims any warranty whether express or implied of fitness for a particular purpose other than the warranty contained herein No implied warr...

Отзывы: