Mobile Home Installation:
For minimum protection, smoke alarms  should be installed in compliance with H.U.D. Manufactured
Home Construction Safety Standards, Title 24 CFR, Section 3280.208 and Section 3282. For additional
protection, see Single Story Residence smoke alarm requirements/recommendations for Existing Homes
and New Construction Homes.

Note: For mobile homes built before 1978, install smoke alarms on inside walls between 4” and 12” from
the ceiling (older mobile homes have little or no insulation in the ceiling). This is especially important if
the ceiling is unusually hot or cold.

Install a smoke alarm inside each bedroom and in the hallway outside each separate sleeping area.

Page 5

AVOID THESE LOCATIONS

the garage – products of combustion are present when you start your automobile.

in areas with high humidity, like bathrooms or areas near dishwashers or washing machines.
Install at least 3 feet (0.9 meters) away from these areas.

in areas of turbulent air such as air returns or heating and cooling supply vents. Install at least 3
feet (0.9 meters) away from these areas.

in extremely dusty, dirty or insect-infested areas. Loose particles interfere with smoke alarm
operation.

in areas where temperature may fall below 40

0

F (4.4

0

C) or rise above 100

0

F (37.8

0

C).

closer than 5 feet (1.5m) from fluorescent lights, electrical "noise" and flickering may affect the
alarm's operation.

do not locate this alarm within 5 feet (1.5m) of any cooking appliance.

in areas of reverse venting of fuel burning appliances caused by outdoor ambient conditions,
such as:
- wind direction and/or velocity, including high gusts of wind. Heavy air in the vent pipes (cold/

humid air with extended periods between cycles).

- negative pressure differential resulting from the use of exhaust fans.
- simultaneous operation of several fuel burning appliances competing for limited internal air.
- vent pipe connections vibrating loose from clothes dryers, furnaces or water heaters.
- obstructions in or unconventional vent pipe designs which can amplify the above situations.
- extended operation of unvented fuel burning devices (range, oven, fireplace, etc.).
- temperature inversions which can trap exhaust gasses near the ground.
- car idling in an open or closed attached garage or near a home.

Содержание CD-9795

Страница 1: ...LIKE A KITCHEN OR IN A HIGH HUMIDITY AREA NEAR A SHOWER CAN CAUSE FALSE ALARMS DO NOT TURN OFF THE AC POWER TO QUIET THE ALARM A SMOKE ALARM WILL NOT HELP PROTECT YOU IF IT IS NOT POWERED Properly locate your alarm to avoid nuisance alarms A SMOKE ALARM MAY NOT ALWAYS WARN YOU ABOUT FIRES CAUSED BY CARELESSNESS AND SAFETY HAZARDS LIKE SMOKING IN BED VIOLENT EXPLOSIONS ESCAPING GAS IMPROPER STORAGE...

Страница 2: ...ling for assistance Young children and household pets may be the first affected Your combination smoke CO alarm is designed to detect the toxic CO fumes that result from incomplete combustion such as those emitted from appliances furnaces fireplaces and auto exhaust This alarm will only indicate the presence of carbon monoxide gas surrounding its sensor Carbon monoxide gas may be present in other ...

Страница 3: ... ready to slam it shut if heat and smoke rush in o Stay close to the floor if air is smoky Breathe shallowly through a cloth wet if possible o Once outside go to your selected meeting place and make sure everyone is there o Call the fire department from your neighbor s home not from yours o Don t return to your home until fire officials say that it is all right to do so Page 3 IMPORTANT CONSIDERAT...

Страница 4: ...n smoke CO alarm should be centrally located outside of each separate sleeping area in the immediate vicinity of the bedrooms Where bedrooms are separated and audibility of the alarm to occupants within the bedroom area could be seriously impaired more than one unit could be needed If a bedroom area hallway is more than 30 feet long install a smoke alarm at each end Alarms can alert you to a probl...

Страница 5: ...s Install at least 3 feet 0 9 meters away from these areas in extremely dusty dirty or insect infested areas Loose particles interfere with smoke alarm operation in areas where temperature may fall below 400 F 4 40 C or rise above 1000 F 37 80 C closer than 5 feet 1 5m from fluorescent lights electrical noise and flickering may affect the alarm s operation do not locate this alarm within 5 feet 1 ...

Страница 6: ... 60Hz circuit Be sure the circuit cannot be turned off by a switch dimmer or ground fault circuit interrupter Failure to connect this unit to a 24 hour circuit may prevent it from providing constant protection IMPORTANT Do not subject this alarm to megger high voltage or high pot tests Remove the alarm s before high potting tests occur on the circuit or system Ref Section 550 17 National Electric ...

Страница 7: ...les RM 100 will not respond if a CO alarm event initiates the alarm Interconnected smoke alarms heat alarms and relay modules will only respond if a smoke alarm event or heat alarm event initiates the alarm All CO alarms remain silent NOTE Units without battery backup will not respond during an AC power failure Page 7 The yellow wire is used only for multiple station operation with Universal Model...

Страница 8: ...en test itself for proper operation of BOTH the SMOKE and CO detection and alarm circuits The Red LED will begin to flash rapidly and the alarm will indicate two cycles of the SMOKE alarm pattern The Red LED will stop flashing during the second SMOKE alarm pattern This will be followed by two cycles of the CO alarm pattern during which the Green LED is off the Yellow LED is on and the Red LED flas...

Страница 9: ...for approximately 3 9 minutes to indicate the alarm is in the temporary silent condition The smoke alarm will gradually regain normal sensitivity and sound the alarm if particles of combustion are still present The silence feature may be used repeatedly until the air has cleared When AC power is lost the Green LED is off and flashes on approximately every 40 seconds ELECTRICAL SHOCK HAZARD Turn of...

Страница 10: ...e unit Return the unit for servicing See warranty for instructions or in warranty returns There will be a service charge for repairing out of warranty units Page 10 NATIONAL FIRE PROTECTION ASSOCIATION REQUIRED PROTECTION For your information the National Fire Protection Association s Standard 72 reads as follows 11 5 1 One and Two Family Dwelling Units 11 5 1 1 Smoke Detection Where required by a...

Страница 11: ...1117 postage prepaid with a payment of 11 00 to cover the costs of return postage and handling You must include a proof of purchase receipt along with the returned product UNIVERSAL DOES NOT WARRANT AND SPECIFICALLY DISCLAIMS ANY WARRANTY WHETHER EXPRESS OR IMPLIED OF FITNESS FOR A PARTICULAR PURPOSE OTHER THAN THE WARRANTY CONTAINED HEREIN NO IMPLIED WARRANTY ON THIS PRODUCT CREATED BY STATE LAW ...

Отзывы: