Universal CD-9795 Скачать руководство пользователя страница 3

WHAT YOU SHOULD DO IF THE SMOKE ALARM SOUNDS

YOU MUST QUICKLY DO THE FOLLOWING:
If the smoke alarm sounds and you have not pushed the test button, it is a warning of a
dangerous situation.
Your immediate response is necessary. To prepare for such occurrences, develop family
escape plans, discuss them with ALL household members and practice them regularly.
BASICS OF ESCAPE PLAN

o Make a floor plan indicating all doors and windows and at least two escape routes from each

room. Second story windows may need a rope or chain ladder.

o Have a family meeting and discuss your escape plan, showing everyone what to do in case of

fire.

o Determine a place outside your home where all of you can meet if a fire occurs.
o Familiarize everyone with the sound of the smoke alarm and train them to leave your home when they

hear the sound.

o Identify children's bedrooms with red stickers placed in the upper left corner of the windows. They

are available from your local fire department.

o Practice a fire drill at least every six months. Practice allows you to test your plan before an

emergency. You may not be able to reach your children. It is important they know what to do!

WHAT TO DO WHEN THE SMOKE ALARM SOUNDS

o Leave immediately by your plan of escape. Every second counts, so don't waste time getting

dressed or picking up valuables.

o In leaving, don't open any inside door without first feeling its surface. If hot, or if you see smoke

seeping through cracks, 

don't open that door!

   Instead, use your alternate exit. If inside door is

cool, place your shoulder against it, open it slightly and be ready to slam it shut if heat and smoke
rush in.

o Stay close to the floor if air is smoky. Breathe shallowly through a cloth, wet if possible.
o Once outside, go to your selected meeting place and make sure everyone is there.
o Call the fire department from your neighbor's home – 

not from yours!

o Don't return to your home until fire officials say that it is all right to do so.

Page 3

IMPORTANT CONSIDERATIONS

YOUR COMBINATION SMOKE/CO ALARM IS WARRANTED TO OPERATE
FOR FIVE YEARS.

NOTE: MANUFACTURER RECOMMENDS REPLACEMENT OF ALARM FIVE
YEARS AFTER DATE OF PURCHASE.

Activation of this device indicates the presence of carbon monoxide
(CO) which can kill you. If the CO alarm sounds:

1.

Operate test/reset button;

2.

Call your emergency services, fire department or 911;

3.

Immediately move to fresh air - outdoors or by an open door/window. Do a head count
to check that all persons are accounted for. Do not reenter the premises nor move
away from the open door/window until the emergency services responders have arrived,
the premises have been aired out, and your alarm remains in its normal condition.

4.

After following steps 1-3, if your alarm reactivates within a 24 hour period, repeat steps
1-3 and call a qualified appliance technician;

 

to

investigate for sources of CO from fuel burning equipment and appliances and inspect
for proper operation of this equipment. If problems are identified during this inspection,
have the equipment serviced immediately. Note any combustion equipment not
inspected by the technician and consult the manufacturers' instructions or contact the
manufacturer(s) directly for more information about CO safety and this equipment.
Make sure that motor vehicles are not, and have not been, operating in an attached
garage or adjacent to the residence.

(

Phone No. 

                             )

(

Phone No. 

                                    )

Содержание CD-9795

Страница 1: ...LIKE A KITCHEN OR IN A HIGH HUMIDITY AREA NEAR A SHOWER CAN CAUSE FALSE ALARMS DO NOT TURN OFF THE AC POWER TO QUIET THE ALARM A SMOKE ALARM WILL NOT HELP PROTECT YOU IF IT IS NOT POWERED Properly locate your alarm to avoid nuisance alarms A SMOKE ALARM MAY NOT ALWAYS WARN YOU ABOUT FIRES CAUSED BY CARELESSNESS AND SAFETY HAZARDS LIKE SMOKING IN BED VIOLENT EXPLOSIONS ESCAPING GAS IMPROPER STORAGE...

Страница 2: ...ling for assistance Young children and household pets may be the first affected Your combination smoke CO alarm is designed to detect the toxic CO fumes that result from incomplete combustion such as those emitted from appliances furnaces fireplaces and auto exhaust This alarm will only indicate the presence of carbon monoxide gas surrounding its sensor Carbon monoxide gas may be present in other ...

Страница 3: ... ready to slam it shut if heat and smoke rush in o Stay close to the floor if air is smoky Breathe shallowly through a cloth wet if possible o Once outside go to your selected meeting place and make sure everyone is there o Call the fire department from your neighbor s home not from yours o Don t return to your home until fire officials say that it is all right to do so Page 3 IMPORTANT CONSIDERAT...

Страница 4: ...n smoke CO alarm should be centrally located outside of each separate sleeping area in the immediate vicinity of the bedrooms Where bedrooms are separated and audibility of the alarm to occupants within the bedroom area could be seriously impaired more than one unit could be needed If a bedroom area hallway is more than 30 feet long install a smoke alarm at each end Alarms can alert you to a probl...

Страница 5: ...s Install at least 3 feet 0 9 meters away from these areas in extremely dusty dirty or insect infested areas Loose particles interfere with smoke alarm operation in areas where temperature may fall below 400 F 4 40 C or rise above 1000 F 37 80 C closer than 5 feet 1 5m from fluorescent lights electrical noise and flickering may affect the alarm s operation do not locate this alarm within 5 feet 1 ...

Страница 6: ... 60Hz circuit Be sure the circuit cannot be turned off by a switch dimmer or ground fault circuit interrupter Failure to connect this unit to a 24 hour circuit may prevent it from providing constant protection IMPORTANT Do not subject this alarm to megger high voltage or high pot tests Remove the alarm s before high potting tests occur on the circuit or system Ref Section 550 17 National Electric ...

Страница 7: ...les RM 100 will not respond if a CO alarm event initiates the alarm Interconnected smoke alarms heat alarms and relay modules will only respond if a smoke alarm event or heat alarm event initiates the alarm All CO alarms remain silent NOTE Units without battery backup will not respond during an AC power failure Page 7 The yellow wire is used only for multiple station operation with Universal Model...

Страница 8: ...en test itself for proper operation of BOTH the SMOKE and CO detection and alarm circuits The Red LED will begin to flash rapidly and the alarm will indicate two cycles of the SMOKE alarm pattern The Red LED will stop flashing during the second SMOKE alarm pattern This will be followed by two cycles of the CO alarm pattern during which the Green LED is off the Yellow LED is on and the Red LED flas...

Страница 9: ...for approximately 3 9 minutes to indicate the alarm is in the temporary silent condition The smoke alarm will gradually regain normal sensitivity and sound the alarm if particles of combustion are still present The silence feature may be used repeatedly until the air has cleared When AC power is lost the Green LED is off and flashes on approximately every 40 seconds ELECTRICAL SHOCK HAZARD Turn of...

Страница 10: ...e unit Return the unit for servicing See warranty for instructions or in warranty returns There will be a service charge for repairing out of warranty units Page 10 NATIONAL FIRE PROTECTION ASSOCIATION REQUIRED PROTECTION For your information the National Fire Protection Association s Standard 72 reads as follows 11 5 1 One and Two Family Dwelling Units 11 5 1 1 Smoke Detection Where required by a...

Страница 11: ...1117 postage prepaid with a payment of 11 00 to cover the costs of return postage and handling You must include a proof of purchase receipt along with the returned product UNIVERSAL DOES NOT WARRANT AND SPECIFICALLY DISCLAIMS ANY WARRANTY WHETHER EXPRESS OR IMPLIED OF FITNESS FOR A PARTICULAR PURPOSE OTHER THAN THE WARRANTY CONTAINED HEREIN NO IMPLIED WARRANTY ON THIS PRODUCT CREATED BY STATE LAW ...