IMPORTANT SAFETY INFORMATION

About this Alarm

This combination alarm has separate sensors to detect smoke and carbon monoxide (CO).
The smoke alarm has priority over the CO alarm.

The combination smoke/CO alarm is designed to be used in ordinary indoor locations of
single-family households only.

The sensitivity of both the smoke and CO sensors and the horn patterns for both warnings,
comply with UL standards.

This combination smoke/CO alarm can be used as a replacement for all UNIVERSAL
Smoke and CO Alarms without additional wiring. This allows the user to easily upgrade
from individual smoke or CO alarms to a combination unit.

WHAT YOU SHOULD KNOW ABOUT CARBON MONOXIDE (CO)

Carbon monoxide (CO) is an insidious poison. It is a colorless, odorless, tasteless gas. It is
a cumulative poison. Even low levels of CO have been shown to cause brain and other vital
organ damage in unborn infants with no effect on the mother.

The following symptoms are related to CARBON MONOXIDE POISONING and should be
discussed with ALL members of the household:

MILD EXPOSURE

Slight headache, nausea, vomiting, fatigue (often described as "flu-like" symptoms).

MEDIUM EXPOSURE

Severe throbbing headache, drowsiness, confusion, fast heart rate.

EXTREME EXPOSURE

Unconsciousness, convulsions, cardiorespiratory failure, death.

Many cases of reported CARBON MONOXIDE POISONING indicate that victims are aware
they are not well, but they become so disoriented that they are unable to save themselves
by either exiting the building or calling for assistance. Young children and household pets
may be the first affected.

Your combination smoke/CO alarm is designed to detect the toxic CO fumes that result
from incomplete combustion, such as those emitted from appliances, furnaces, fireplaces
and auto exhaust.

This alarm will only indicate the presence of carbon monoxide gas surrounding its sensor.
Carbon monoxide gas may be present in other areas.

This product is intended for use in ordinary indoor locations of family living units. It is not
designed to measure compliance with Occupational Safety and Health Administration
(OSHA) commercial or industrial standards. Individuals with medical problems may consider
using warning devices which provide audible and visual warnings for carbon monoxide
concentrations under 30 PPM.

WHAT YOU SHOULD DO IF THE CO ALARM SOUNDS

Never disconnect a combination Smoke/CO alarm to silence an alarm. The alarm will
automatically sense when the level of CO in the air falls below the danger level. You should
stay outside the residence in fresh air until the alarm is silenced. When the alarm sounds,
do not stand too close to the alarm. The sound produced by the alarm is loud because it is
designed to awaken a person in an emergency. Prolonged exposure to the alarm at a close
distance may be harmful to your hearing.

Two self-adhesive labels have been provided with instructions indicating what to do if the
CO alarm sounds. Add the phone numbers of your emergency services provider and a
qualified technician to each label. Place one of the labels in a visible area next to the alarm
and place the other label near a source of fresh air which will be used as a gathering place
if the alarm sounds.

Page 2

Содержание CD-9795

Страница 1: ...LIKE A KITCHEN OR IN A HIGH HUMIDITY AREA NEAR A SHOWER CAN CAUSE FALSE ALARMS DO NOT TURN OFF THE AC POWER TO QUIET THE ALARM A SMOKE ALARM WILL NOT HELP PROTECT YOU IF IT IS NOT POWERED Properly locate your alarm to avoid nuisance alarms A SMOKE ALARM MAY NOT ALWAYS WARN YOU ABOUT FIRES CAUSED BY CARELESSNESS AND SAFETY HAZARDS LIKE SMOKING IN BED VIOLENT EXPLOSIONS ESCAPING GAS IMPROPER STORAGE...

Страница 2: ...ling for assistance Young children and household pets may be the first affected Your combination smoke CO alarm is designed to detect the toxic CO fumes that result from incomplete combustion such as those emitted from appliances furnaces fireplaces and auto exhaust This alarm will only indicate the presence of carbon monoxide gas surrounding its sensor Carbon monoxide gas may be present in other ...

Страница 3: ... ready to slam it shut if heat and smoke rush in o Stay close to the floor if air is smoky Breathe shallowly through a cloth wet if possible o Once outside go to your selected meeting place and make sure everyone is there o Call the fire department from your neighbor s home not from yours o Don t return to your home until fire officials say that it is all right to do so Page 3 IMPORTANT CONSIDERAT...

Страница 4: ...n smoke CO alarm should be centrally located outside of each separate sleeping area in the immediate vicinity of the bedrooms Where bedrooms are separated and audibility of the alarm to occupants within the bedroom area could be seriously impaired more than one unit could be needed If a bedroom area hallway is more than 30 feet long install a smoke alarm at each end Alarms can alert you to a probl...

Страница 5: ...s Install at least 3 feet 0 9 meters away from these areas in extremely dusty dirty or insect infested areas Loose particles interfere with smoke alarm operation in areas where temperature may fall below 400 F 4 40 C or rise above 1000 F 37 80 C closer than 5 feet 1 5m from fluorescent lights electrical noise and flickering may affect the alarm s operation do not locate this alarm within 5 feet 1 ...

Страница 6: ... 60Hz circuit Be sure the circuit cannot be turned off by a switch dimmer or ground fault circuit interrupter Failure to connect this unit to a 24 hour circuit may prevent it from providing constant protection IMPORTANT Do not subject this alarm to megger high voltage or high pot tests Remove the alarm s before high potting tests occur on the circuit or system Ref Section 550 17 National Electric ...

Страница 7: ...les RM 100 will not respond if a CO alarm event initiates the alarm Interconnected smoke alarms heat alarms and relay modules will only respond if a smoke alarm event or heat alarm event initiates the alarm All CO alarms remain silent NOTE Units without battery backup will not respond during an AC power failure Page 7 The yellow wire is used only for multiple station operation with Universal Model...

Страница 8: ...en test itself for proper operation of BOTH the SMOKE and CO detection and alarm circuits The Red LED will begin to flash rapidly and the alarm will indicate two cycles of the SMOKE alarm pattern The Red LED will stop flashing during the second SMOKE alarm pattern This will be followed by two cycles of the CO alarm pattern during which the Green LED is off the Yellow LED is on and the Red LED flas...

Страница 9: ...for approximately 3 9 minutes to indicate the alarm is in the temporary silent condition The smoke alarm will gradually regain normal sensitivity and sound the alarm if particles of combustion are still present The silence feature may be used repeatedly until the air has cleared When AC power is lost the Green LED is off and flashes on approximately every 40 seconds ELECTRICAL SHOCK HAZARD Turn of...

Страница 10: ...e unit Return the unit for servicing See warranty for instructions or in warranty returns There will be a service charge for repairing out of warranty units Page 10 NATIONAL FIRE PROTECTION ASSOCIATION REQUIRED PROTECTION For your information the National Fire Protection Association s Standard 72 reads as follows 11 5 1 One and Two Family Dwelling Units 11 5 1 1 Smoke Detection Where required by a...

Страница 11: ...1117 postage prepaid with a payment of 11 00 to cover the costs of return postage and handling You must include a proof of purchase receipt along with the returned product UNIVERSAL DOES NOT WARRANT AND SPECIFICALLY DISCLAIMS ANY WARRANTY WHETHER EXPRESS OR IMPLIED OF FITNESS FOR A PARTICULAR PURPOSE OTHER THAN THE WARRANTY CONTAINED HEREIN NO IMPLIED WARRANTY ON THIS PRODUCT CREATED BY STATE LAW ...

Отзывы: