BACKUP BATTERY REPLACEMENT

Disconnect AC power before changing battery. Shock hazard exists if AC power is miswired.

The smoke alarm uses a 9 Volt battery. The battery should last for at least one year under normal
operating conditions. The smoke alarm has a low battery indicator, an audible "beep." It will operate
at 30-40 second intervals for a minimum of 7 days. When this indication occurs, replace the battery
with an Alkaline type (Eveready Energizer #522, Duracell #MN1604), Carbon-Zinc type (Gold Peak
#1604P, Eveready #216). Use the convenient QUICK DRAW

(R)

 

pull-out batterydrawer for easy battery

replacement.

Pull the QUICK DRAW

(R) 

battery drawer open and remove the battery. While observing polarity,

push the replacement battery into the battery drawer until it is held securely in place. Carefully close
and latch the battery drawer.

REPAIRS AND SERVICES

The smoke alarm contains less than 1 microcurie (37 kilobecquerel) of Americium 241, a radioactive
material. 

The distribution of these ionization-type smoke alarms is licensed by the U.S. Nuclear

Regulatory Commission; the consumer is exempt from any licensing or requirements.

 If the

smoke alarm is defective in any way, do not tamper with the unit. Return the unit for servicing. (See
warranty for instructions or in-warranty returns.) There will be a service charge for repairing out of
warranty units.

Page 6

Before using the alarm "silence" feature, identify the source of smoke and be certain that
safe conditions exist.

(UTHA) MAINTENANCE:

The smoke alarm is virtually maintenance free. However, under dusty conditions, a vacuum hose
may be used to clear the sensing chamber of dust.

Clean the smoke alarm at least once a month

 to remove dust, dirt or debris. Always turn off power

to smoke alarm before cleaning. Using a soft brush or wand attachment to a vacuum cleaner,
vacuum all sides and cover of smoke alarm. Be sure all the vents are free of debris.

If the smoke alarm is false alarming and cannot be restored to normal operation, the smoke alarm
should be replaced.

Содержание USI-5204

Страница 1: ...OR INSURANCE Homeowners and renters alike should continue to insure their lives and properties SMOKEALARMS CANNOTWORK WITHOUT POWER Battery operated units cannot work if the batteries are missing disconnected or dead if the wrong type of batteries are used or if the batteries are not installed correctly AC only powered units cannot work if the AC power is cut off for any reason If you are concerne...

Страница 2: ...102 mm vertically to the peak Sloped Ceilings Shed Ceilings Smoke alarms or smoke detectors mounted on a sloped ceiling having a rise greater than 1 ft in 8 ft 1 m in 8 m horizontally shall be located within 36 in 914 mm of the high side of the ceiling but not closer than 4 in 102 mm from the adjoining wall surface Tray Shaped Ceilings Smoke Alarms or smoke detectors shall be installed on the high...

Страница 3: ...h potting tests occur on the circuit or system Ref Section 550 17 National Electric Code 2002 Edition ELECTRICAL SHOCK HAZARD Turn off power to the area where you will install this unit at the circuit breaker or fuse box before beginning installation Failure to turn off the power before installation may result in serious electrical shock injury or death TAMPER LOCKING PIN To make your alarm somewh...

Страница 4: ...ally if a fire starts in a remote area of the dwelling This smoke alarm may be interconnected with as many as 11 other USI ELECTRIC model smoke alarms such as USI 1103 USI 1203 USI 1204 USI 1209 USI 1213 USI 2204 USI 3204 and 6 other units which may be a combination of Carbon Monoxide Alarms such as USI 7385 USI 7390 USI 7485 USI 7490 USI 7795 Heat Alarms USI 2430 or Relay Modules USI 960 for a to...

Страница 5: ...ed Use of non UL Listed products or improper use of UL Listed products may affect the smoke alarm s sensitivity FALSE ALARMS SILENCE CONTROL Units with the silence feature have the capability of temporarily reducing the sensitivity of the alarm circuit for approximately 3 9 minutes This feature is to be used only when a known alarm condition such as smoke from cooking activates the smoke alarm The...

Страница 6: ...ilobecquerel ofAmericium 241 a radioactive material The distribution of these ionization type smoke alarms is licensed by the U S Nuclear Regulatory Commission the consumer is exempt from any licensing or requirements If the smoke alarm is defective in any way do not tamper with the unit Return the unit for servicing See warranty for instructions or in warranty returns There will be a service char...

Страница 7: ... right to do so NATIONAL FIRE PROTECTION ASSOCIATION REQUIRED PROTECTION For your information the National Fire Protection Association s Standard 72 reads as follows 11 5 1 One and Two Family Dwelling Units 11 5 1 1 Smoke Detection Where required by applicable laws codes or standards for the specified occupancy approved single and multiple station smoke alarms shall be installed as follows 1 In al...

Страница 8: ...o cover the costs of return postage and handling You must include a proof of purchase receipt along with the returned product USI DOES NOT WARRANT AND SPECIFICALLY DISCLAIMS ANY WARRANTY WHETHER EXPRESS OR IMPLIED OF FITNESS FOR A PARTICULAR PURPOSE OTHER THAN THE WARRANTY CONTAINED HEREIN NO IMPLIED WARRANTY ON THIS PRODUCT CREATED BY STATE LAW SHALL EXTEND BEYOND THE TERM OF THIS WARRANTY UNLESS...

Отзывы: