OPERATION, TESTING & MAINTENANCE

OPERATION:

 The smoke alarm is operating once the power is connected and turned on (the battery

must also be installed). When products of combustion are sensed, the unit sounds a loud alarm
which continues until the air is cleared.

This alarm incorporates the internationally recognized horn signal for evacuation. During alarm
mode, the horn produces three short beeps followed by a two second pause and then repeats.

STANDBY  CONDITION:

 The red LED (SS-771-LR only) flashes once every 40-60 seconds to

indicate the unit is properly functioning.

LOCAL ALARM CONDITION:

 The red LED (SS-771-LR only) flashes rapidly and the unit emits a

loud, pulsating alarm sound.

TESTING:

 Test by pushing the test button on the smoke alarm cover until the alarm sounds, then

release. The alarm sounds if all electronic circuitry, horn and battery are working. The alarm may
continue to sound for up to 10 seconds after the button is released. If no alarm sounds, the unit
may have a defective battery or other failure. Test the smoke alarm weekly to assure proper
operation.

NEVER use an open flame of any kind to test this unit. You might accidentally damage or set
fire to the unit or to your home. The built-in test switch accurately tests the unit's operation as
required by Underwriters Laboratories Inc. (UL).

If you choose to use an aerosol smoke product to test the smoke alarm, be certain to use one
that has been Listed to Underwriters Laboratories, Inc. Safety Standards and use it only as
directed. Use of non-UL Listed products or improper use of UL Listed products may affect
the smoke alarm's sensitivity.

RV INSTALLATION -
WARNING:

 TEST SMOKE ALARM OPERATION AFTER VEHICLE HAS BEEN IN STORAGE,

BEFORE EACH TRIP, AND AT LEAST ONCE PER WEEK DURING USE. An identical marking is to
be provided by the recreational vehicle manufacturer that shall be permanent and located, visibly,
within 24 inches (610mm) of the smoke alarm.

MAINTENANCE:

 The smoke alarm is virtually maintenance free. However, under dusty conditions,

a vacuum hose may be used to clear the sensing chamber of dust.

BATTERY REPLACEMENT

The smoke alarm uses a 9 Volt carbon-zinc battery. The battery should last for at least one year
under normal operating conditions. The smoke alarm has a low battery indicator, an audible "beep."
It will operate at 30-40 second intervals for a minimum of 7 days. When this indication occurs,
replace the battery with an Alkaline type (Eveready Energizer #522, Duracell #MN1604), Carbon-
Zinc type (Gold Peak #1604P, Eveready #216).

REPAIRS AND SERVICES

The smoke alarm contains less than 1 microcurie (37 kilobecquerel) of Americium 241, a radioactive
material. 

The distribution of these ionization-type smoke alarms is licensed by the U.S. Nuclear

Regulatory Commission; the consumer is exempt from any licensing or requirements.

 If the

smoke alarm is defective in any way, do not tamper with the unit. Return the unit for servicing. (See
warranty for instructions or in-warranty returns.) There will be a service charge for repairing out of
warranty units.

Содержание UNIVERSAL SS-770-LR

Страница 1: ...SMOKE ALARMS ARE NOT A SUBSTITUTE FOR INSURANCE Homeowners and renters alike should continue to insure their lives and properties SMOKE ALARMS CANNOT WORK WITHOUT POWER Battery operated units cannot work if the batteries are missing disconnected or dead if the wrong type of batteries are used or if the batteries are not installed correctly AC only powered units cannot work if the AC power is cut o...

Страница 2: ...102 mm vertically to the peak Sloped Ceilings Shed Ceilings Smoke alarms or smoke detectors mounted on a sloped ceiling having a rise greater than 1 ft in 8 ft 1 m in 8 m horizontally shall be located within 36 in 914 mm of the high side of the ceiling but not closer than 4 in 102 mm from the adjoining wall surface Tray Shaped Ceilings Smoke Alarms or smoke detectors shall be installed on the high...

Страница 3: ...d Second push and turn the smoke alarm clockwise onto the mounting ring Note Your smoke alarm is equipped with a safety device which prevents mounting unless a battery is installed If your smoke alarm will not lock into the mounting ring check to make sure a battery is installed Early warning fire detection is best achieved by the installation of fire detection equipment in all rooms and areas of ...

Страница 4: ...has been Listed to Underwriters Laboratories Inc Safety Standards and use it only as directed Use of non UL Listed products or improper use of UL Listed products may affect the smoke alarm s sensitivity RV INSTALLATION WARNING TEST SMOKE ALARM OPERATION AFTER VEHICLE HAS BEEN IN STORAGE BEFORE EACH TRIP ANDAT LEAST ONCE PER WEEK DURING USE An identical marking is to be provided by the recreational...

Страница 5: ...is all right to do so NATIONAL FIRE PROTECTION ASSOCIATION REQUIRED PROTECTION For your information the National Fire Protection Association s Standard 72 reads as follows 11 5 1 One and Two Family Dwelling Units 11 5 1 1 Smoke Detection Where required by applicable laws codes or standards for the specified occupancy approved single and multiple station smoke alarms shall be installed as follows 1...

Страница 6: ... a payment of 4 00 to cover the costs of return postage and handling You must include a proof of purchase receipt along with the returned product UNIVERSAL DOES NOT WARRANT AND SPECIFICALLY DISCLAIMS ANY WARRANTY WHETHER EXPRESS OR IMPLIED OF FITNESS FOR A PARTICULAR PURPOSE OTHER THAN THE WARRANTY CONTAINED HEREIN NO IMPLIED WARRANTY ON THIS PRODUCT CREATED BY STATE LAW SHALL EXTEND BEYOND THE TE...

Отзывы: