THIS SMOKE ALARM WILL NOT OPERATE WITHOUT A BATTERY INSTALLED.
PROPER  BATTERY MUST BE INSTALLED IMMEDIATELY WHEN LOW
BATTERY SIGNAL IS GIVEN OR THE UNIT WILL FAIL. TEST WEEKLY. READ
AND FOLLOW ALL INSTRUCTIONS OR UNIT WILL NOT OPERATE PROPERLY.

FALSE ALARMS

The smoke alarm is designed to minimize false alarms. Smoking will not normally set
off the alarm unless smoke is blown directly into the smoke alarm. Combustion particles
from cooking may set off the alarm if the smoke alarm is located close  to the kitchen
cooking surface. Large quantities of combustion particles are generated from spills or
broiling.

If the smoke alarm does alarm, check for fires first. If a fire is discovered, get out and
call the fire department. If no fire is present, check to see if one of the reasons listed
above may have caused the alarm.

TAMPER LOCKING PIN

To make your smoke alarm somewhat tamper resistant, a locking pin has been provided. Using this
pin will deter children and others from removing the alarm from the mounting ring. To use the pin,
insert it into the hole in the side of the alarm after it has been installed on the mounting ring. Note that
the tamper pin will have to be removed in order to change the battery, which can be done easily with
a pair of long nose pliers. Using the long nose pliers, pull the pin out of the hole. It is now possible to
remove the smoke alarm from the mounting ring.

INSTALLATION

Your smoke alarm is designed for easy mounting on wall or ceiling. A complete mounting kit is
included with the smoke alarm. First, attach the mounting ring on the wall or ceiling with the screws
provided. Second, push and turn the  smoke alarm clockwise onto the mounting ring. (Note: Your
smoke alarm is equipped with a safety device which prevents mounting unless a battery is installed.
If your smoke alarm will not lock into the mounting ring, check to make sure a battery is installed.)

Early warning fire detection is best achieved by the installation of fire detection equipment in
all rooms and areas of the household as follows: A smoke alarm installed in each separate
sleeping area (in the vicinity of, but outside of, the bedrooms) and heat or smoke alarms in
living rooms, dining rooms, kitchens, hallways, attics, furnace rooms, closets, utility storage
rooms, basements and attached garages. Test the smoke alarm weekly to assure proper
operation.

Page 3

AVOID THESE LOCATIONS

the garage – products of combustion are present when you start your automobile.

near appliances or areas where normal combustion regularly occurs (kitchens, near furnaces,
gas hot water heaters). Use smoke alarms with Silence Control for these areas.

in areas with high humidity, like bathrooms or areas near dishwashers or washing machines.
Install at least 3 feet (0.9 meters) away from these areas.

in areas of turbulent air such as air returns or heating and cooling supply vents, smoke alarms
shall not be located where airflow prevents operation of the alarms.

in extremely dusty, dirty or insect-infested areas. Loose particles interfere with smoke alarm
operation.

in areas where temperature may fall below 40

0

F (4.4

0

C) or rise above 100

0

F (37.8

0

C).

closer than 1 foot (0.3m) from fluorescent lights, electrical "noise" and flickering may affect the
alarm's operation.

closer than 3 feet (0.9m) horizontal path from the tip of the blade of a ceiling suspended (paddle)
fan.

on a poorly insulated ceiling or exterior wall (mount smoke alarm on an inside wall).

Содержание UNIVERSAL SS-770-LR

Страница 1: ...SMOKE ALARMS ARE NOT A SUBSTITUTE FOR INSURANCE Homeowners and renters alike should continue to insure their lives and properties SMOKE ALARMS CANNOT WORK WITHOUT POWER Battery operated units cannot work if the batteries are missing disconnected or dead if the wrong type of batteries are used or if the batteries are not installed correctly AC only powered units cannot work if the AC power is cut o...

Страница 2: ...102 mm vertically to the peak Sloped Ceilings Shed Ceilings Smoke alarms or smoke detectors mounted on a sloped ceiling having a rise greater than 1 ft in 8 ft 1 m in 8 m horizontally shall be located within 36 in 914 mm of the high side of the ceiling but not closer than 4 in 102 mm from the adjoining wall surface Tray Shaped Ceilings Smoke Alarms or smoke detectors shall be installed on the high...

Страница 3: ...d Second push and turn the smoke alarm clockwise onto the mounting ring Note Your smoke alarm is equipped with a safety device which prevents mounting unless a battery is installed If your smoke alarm will not lock into the mounting ring check to make sure a battery is installed Early warning fire detection is best achieved by the installation of fire detection equipment in all rooms and areas of ...

Страница 4: ...has been Listed to Underwriters Laboratories Inc Safety Standards and use it only as directed Use of non UL Listed products or improper use of UL Listed products may affect the smoke alarm s sensitivity RV INSTALLATION WARNING TEST SMOKE ALARM OPERATION AFTER VEHICLE HAS BEEN IN STORAGE BEFORE EACH TRIP ANDAT LEAST ONCE PER WEEK DURING USE An identical marking is to be provided by the recreational...

Страница 5: ...is all right to do so NATIONAL FIRE PROTECTION ASSOCIATION REQUIRED PROTECTION For your information the National Fire Protection Association s Standard 72 reads as follows 11 5 1 One and Two Family Dwelling Units 11 5 1 1 Smoke Detection Where required by applicable laws codes or standards for the specified occupancy approved single and multiple station smoke alarms shall be installed as follows 1...

Страница 6: ... a payment of 4 00 to cover the costs of return postage and handling You must include a proof of purchase receipt along with the returned product UNIVERSAL DOES NOT WARRANT AND SPECIFICALLY DISCLAIMS ANY WARRANTY WHETHER EXPRESS OR IMPLIED OF FITNESS FOR A PARTICULAR PURPOSE OTHER THAN THE WARRANTY CONTAINED HEREIN NO IMPLIED WARRANTY ON THIS PRODUCT CREATED BY STATE LAW SHALL EXTEND BEYOND THE TE...

Отзывы: