DO NOT TAMPER WITH WIRES WHEN POWER IS ON!

For alarms that are used as single non-interconnected, stand-alone alarms, do not connect the
yellow wire to anything. Insulate this wire (tape it) in place to make certain the yellow wire cannot
contact any metal parts.

INTERCONNECTION & COMPATIBILITY: Interconnected alarms can provide earlier
warning of fire than stand-alone alarms, especially if a fire starts in a remote area of the
dwelling. When alarms are interconnected, all alarms will sound when one alarm first
goes into alarm. This alarm may be interconnected with a total of not more than 24
interconnected devices, i.e., as many as 11 other USI ELECTRIC or UNIVERSAL model
smoke alarms or combination smoke and carbon monoxide (CO) or smoke and carbon
monoxide / natural gas alarms; 6 other initiating alarms which may be a combination of
USI ELECTRIC or UNIVERSAL CO Alarms and Heat Alarms; and six other non-initiating
devices such as USI ELECTRIC Relay Modules.

This alarm can be interconnected with the following models:  2995, 5304, MI100, MI106,
MDS211, MDS201, 2985, 5303, MI200, MI210, MDS101, MDS107, 3885, 3895, MP118, MP117,
3303, 3304, MP202, MP212, MDSCN111, MDSCN103, MICN109, MICN102, MCN105, MCN108,
SS-785, SS-790, SS-795, SS-2795, SS-2790, SS-2785, SS-2895, HD-130, USI-1103, USI-1203,
USI-1204, USI-1208 (Part #USI-1209
), USI-1213, USI-2430, USI-3204, USI-5204, USI-5208,
USI-5213, USI-7385, USI-7390, USI-7485, USI-7490, CD-9385, CD-9390, CD-9485, CD-9490,
CD-9795, USI-7795 AND USI-960, RM-100 Relay.

When any one of these interconnected models goes into alarm, it will trigger the
corresponding alarm within the interconnected system with respect to their sensing
capabilities. Natural gas detection is only present in models MDSCN111, MSDCN103,
MICN109, MICN102, MCN108 and MCN105; therefore, a natural gas alarm will NOT
trigger the alarm of non-natural gas sensing models within an interconnected system.

The following alarms cannot reset units on an interconnected system: USI-7795, CD-
9795, USI-7385, USI-7390, USI-7485, USI-7490, CD-9385, CD-9390, CD-9485, CD-9490.

The following alarms cannot trigger QUICK FIND

®

  Alarm Origination on an

interconnected system: USI-7385, USI-7390, USI-7485, USI-7490, CD-9385, CD-9390, CD-
9485, CD-9490.

The following alarms can trigger QUICK FIND

®

  Alarm Origination, but will not indicate

Alarm Origination on an interconnected system: USI-1103USI-1203, USI-1204, USI-1208
(Part #USI-1209
), USI-1213, USI-5204, USI-5208, USI-5213, USI-3204, CD-9795, USI-7795,
USI-2430, SS-785, SS-790, SS-795, SS-2795, SS-2790, SS-2785, SS-2895, HD-130.

The following alarms cannot be reset through an interconnected system because they
do not have QUICK FIND

®

   Alarm Origination: USI-1103,  USI-1203, USI-1204, USI-1208

(Part #USI-1209),  USI-1213, USI-5204, USI-5208, USI-5213, USI-3204, USI-2430, SS-785,
SS-790, SS-795, SS-2795, SS-2790, SS-2785, SS-2895, USI-7385, USI-7390, USI-7485, USI-
7490, CD-9385, CD-9390, CD-9485, CD-9490, CD-9795, USI-7795.

Interconnected CO alarms or CO alarm circuit of combination smoke and CO and Natural
Gas alarms will only respond if a CO alarm / event initiates the alarm. All other alarms
remain silent.

Interconnected combination Natural Gas Alarms will only respond if a natural gas event
initiated the alarm. All other alarms remain silent.

Interconnected smoke alarms, heat alarms and relay modules will only respond if a smoke
alarm / event or heat alarm / event initiates the alarm. All CO and Natural Gas alarms
remain silent.

Note that smoke alarms without battery backup will not respond during an AC power failure.

NOTE: Relay Modules/USI-960 will not respond if a CO or Natural Gas alarm / event
initiates the alarm.

Page 8

c.

There are three pigtail wires (black, white and yellow) coming from the AC QUICK
CONNECTOR. The proper wire connection is as follows:

WIRES FROM QUICK CONNECTORCONNECT TO

BLACK

"HOT" side of AC line

WHITE

"NEUTRAL" side of AC line

YELLOW

Interconnect wires of other alarms

Содержание MICN102

Страница 1: ...C 60 Hz 100 mAMax SECURITY INSTRUMENTS INC Table of Contents Page Alarm Limitations and Functions 2 What You Should Know About CO 3 What You Should Know About Natural Gas 3 Basic Safety Information 5...

Страница 2: ...SIONS ESCAPING GAS IMPROPER STORAGE OF FLAMMABLE MATERIALS OVERLOADED ELECTRICAL CIRCUITS CHILDREN PLAYING WITH MATCHES NATURAL CAUSES SUCH AS LIGHTNING OR ARSON FIRE PREVENTION IS YOUR BEST SAFEGUARD...

Страница 3: ...ical problems may consider using warning devices which provide audible and visual warnings for carbon monoxide concentrations under 30 ppm IMPORTANT CONSIDERATIONS YOUR COMBINATION SMOKE CO AND NATURA...

Страница 4: ...ceiling shall be located within 36 in 914 mm horizontally of the peak but not closer than 4 in 102 mm vertically to the peak Sloped Ceilings Shed Ceilings Smoke alarms or combination alarms mounted on...

Страница 5: ...to detect any other gas Carbon monoxide and natural gas may be present in other areas The Smoke CO and Natural Gas Alarm will only indicate the presence of CO or natural gas which reaches the sensor D...

Страница 6: ...nted alarms can occur if an alarm is placed directly next to a fuel burning source Ventilate these areas as much as possible If you must install the alarm near a cooking or heating appliance install a...

Страница 7: ...e alarm in the direction indicated by the TWIST TO REMOVE arrow on the side of the alarm base OPTIONAL TAMPER RESISTANT FEATURES There are two separate tamper resistant locking features provided for t...

Страница 8: ...sing models within an interconnected system The following alarms cannot reset units on an interconnected system USI 7795 CD 9795 USI 7385 USI 7390 USI 7485 USI 7490 CD 9385 CD 9390 CD 9485 CD 9490 The...

Страница 9: ...rm utilizes battery backup power the natural gas sensor will operate the alarm and will sample less frequently to extend battery life Natural gas could be present during this period between samples wi...

Страница 10: ...ach alarm event TESTING Test by pushing the Test button on the alarm cover until the alarm sounds then release The alarm will sound 3 beeps approx 2 second pause 3 beeps approx 6 second pause 4 beeps...

Страница 11: ...etected If CO levels drop below alarm levels the alarm will remain silent and return to normal operation If CO levels remain constant or increase this indicates a potentially dangerous situation and t...

Страница 12: ...y damage or set fire to the alarm or to your home The built in test switch accurately tests the unit s operation as required by the UL 217 UL 2034 and UL 1484 Standards NEVER use vehicle exhaust Exhau...

Страница 13: ...self diagnostic test reveals a malfunction immediately have the unit replaced see last page for warranty information Smoke CO and Natural Gas alarms can only sense CO which reaches the alarm s sensor...

Страница 14: ...nsumer is exempt from any licensing or requirements Simultaneous operation of several fuel burning appliances competing for limited internal air Vent pipe connections vibrating loose from clothes drye...

Страница 15: ...sleeping area within 6 4 m 21 ft of any door to a sleeping room the distance measured along a path of travel 3 On every level of a dwelling unit including basements 4 On every level of a residential...

Страница 16: ...ff Blinks On in sync with the 1 beep Condition Originating GAS Alarm Recommendation If hazard is identified take all precautions if an alarm sounds by calling an Emergency Service and getting out of t...

Страница 17: ...enced for a 10 hour period for up to 20 days After 20 days the warning cannot be silenced The alarm should be replaced immediately Silent alarmed previously Off and Blinks On approx every 5 seconds un...

Страница 18: ...ECIFICALLY DISCLAIMS ANY WARRANTY WHETHER EXPRESS OR IMPLIED OF FITNESS FOR A PARTICULAR PURPOSE OTHER THAN THE WARRANTY CONTAINED HEREIN NO IMPLIED WARRANTY ON THIS PRODUCT CREATED BY STATE LAW SHALL...

Отзывы: