Find the pair of self-adhesive labels included with this Smoke, CO and Gas Alarm.

On each label, write in the phone number of your emergency responder (such as 911) and a
qualified appliance technician.

Place one label near the Smoke, CO and Gas Alarm and the other label in the "fresh air" location
you plan to go to if the alarm sounds.

WHAT TO DO IF NATURAL GAS IS DETECTED:

1. Leave the house immediately, opening doors and windows as you leave.
2. Do not use your telephone or appliances. Do not turn any light switches off or on. Any

spark or flame could ignite the gas.

3. Call 911 and your gas company from a phone that is away from your home.
4. Do not reenter the area until the source of the leak is found and corrected.

If the unit alarms and you are not testing the unit, it is warning you of a potentially dangerous
situation which requires your immediate attention. NEVER ignore any alarm. Ignoring the
alarm may result in injury or death.

USING THE SILENCE FEATURE (GAS ALARM SIGNAL CANNOT BE SILENCED)

NEVER 

disconnect the power to your al(arm to silence the horn - use the Silence feature.

Disconnecting the alarm removes your protection!

The Silence feature is intended to temporarily silence the horn while you identify and
correct the problem.

To use the Silence feature, press and release the TEST/SILENCE button until the horn
is silent if it was the initiating alarm.

If the TEST/SILENCE button is pressed while the alarm is in the silence mode, the alarm
will start sounding again.

WHEN THE CO ALARM SIGNAL IS SILENCED:

 The CO alarm Silence Feature can be activated

by pressing and releasing the Test/CO Silence button on the initiating alarm while in alarm
condition. The alarm will remain silent for approx. 5 minutes (with the red LED blinking on approx.
every 10 seconds), depending on the level of CO detected. If CO levels drop below alarm levels,
the alarm will remain silent and return to normal operation. If CO levels remain constant or
increase, this indicates a potentially dangerous situation and the horn will sound again. Ventilate
area.

WHEN THE SMOKE ALARM SIGNAL IS SILENCED:

 The alarm will remain silent for up to approx.

8-12 minutes (with the red LED blinking on approx. every 10 seconds) and then return to normal
operation. Ventilate area. If the smoke has not cleared within the silence period, the unit will go
back into alarm.

IMPORTANT!

The Silence feature is intended to temporarily silence the alarm horn. It will not correct a
Smoke, CO or Natural Gas problem. The Gas Alarm signal cannot be silenced.

RESET:

 

To reset the QUICK FIND

®

 Alarm Origination condition, press and hold the TEST/

SILENCE button on any alarm for at least 10 seconds. or until the blue LED turns on, and
then release. Reset after each alarm. The reset feature will reset all interconnected units.

SENSOR TROUBLE/SERVICE ALARM:

 If the alarm chirps 3 times approx. every 20 seconds

and cannot be restored to normal operation, the alarm should be replaced immediately.

If you hear the alarm horn sound 1 beep, 2 second pause, repeat,

gas has been detected. Evacuate everyone from the building.

4.

After following steps 1-3, if your alarm reactivates within a 24 hour period, repeat steps 1-3
and call a qualified appliance technician to investigate for sources of CO from fuel-burning
equipment and appliances and inspect for proper operation of this equipment. If problems
are identified during this inspection, have the equipment serviced immediately. Note any
combustion equipment not inspected by the technician and consult the manufacturers'
instructions or contact the manufacturer(s) directly for more information about CO safety
and this equipment. Make sure that motor vehicles are not, and have not been, operating in
an attached garage or adjacent to the residence.  Write down the number of your local
emergency service here:

Page 11

Содержание MICN102

Страница 1: ...C 60 Hz 100 mAMax SECURITY INSTRUMENTS INC Table of Contents Page Alarm Limitations and Functions 2 What You Should Know About CO 3 What You Should Know About Natural Gas 3 Basic Safety Information 5...

Страница 2: ...SIONS ESCAPING GAS IMPROPER STORAGE OF FLAMMABLE MATERIALS OVERLOADED ELECTRICAL CIRCUITS CHILDREN PLAYING WITH MATCHES NATURAL CAUSES SUCH AS LIGHTNING OR ARSON FIRE PREVENTION IS YOUR BEST SAFEGUARD...

Страница 3: ...ical problems may consider using warning devices which provide audible and visual warnings for carbon monoxide concentrations under 30 ppm IMPORTANT CONSIDERATIONS YOUR COMBINATION SMOKE CO AND NATURA...

Страница 4: ...ceiling shall be located within 36 in 914 mm horizontally of the peak but not closer than 4 in 102 mm vertically to the peak Sloped Ceilings Shed Ceilings Smoke alarms or combination alarms mounted on...

Страница 5: ...to detect any other gas Carbon monoxide and natural gas may be present in other areas The Smoke CO and Natural Gas Alarm will only indicate the presence of CO or natural gas which reaches the sensor D...

Страница 6: ...nted alarms can occur if an alarm is placed directly next to a fuel burning source Ventilate these areas as much as possible If you must install the alarm near a cooking or heating appliance install a...

Страница 7: ...e alarm in the direction indicated by the TWIST TO REMOVE arrow on the side of the alarm base OPTIONAL TAMPER RESISTANT FEATURES There are two separate tamper resistant locking features provided for t...

Страница 8: ...sing models within an interconnected system The following alarms cannot reset units on an interconnected system USI 7795 CD 9795 USI 7385 USI 7390 USI 7485 USI 7490 CD 9385 CD 9390 CD 9485 CD 9490 The...

Страница 9: ...rm utilizes battery backup power the natural gas sensor will operate the alarm and will sample less frequently to extend battery life Natural gas could be present during this period between samples wi...

Страница 10: ...ach alarm event TESTING Test by pushing the Test button on the alarm cover until the alarm sounds then release The alarm will sound 3 beeps approx 2 second pause 3 beeps approx 6 second pause 4 beeps...

Страница 11: ...etected If CO levels drop below alarm levels the alarm will remain silent and return to normal operation If CO levels remain constant or increase this indicates a potentially dangerous situation and t...

Страница 12: ...y damage or set fire to the alarm or to your home The built in test switch accurately tests the unit s operation as required by the UL 217 UL 2034 and UL 1484 Standards NEVER use vehicle exhaust Exhau...

Страница 13: ...self diagnostic test reveals a malfunction immediately have the unit replaced see last page for warranty information Smoke CO and Natural Gas alarms can only sense CO which reaches the alarm s sensor...

Страница 14: ...nsumer is exempt from any licensing or requirements Simultaneous operation of several fuel burning appliances competing for limited internal air Vent pipe connections vibrating loose from clothes drye...

Страница 15: ...sleeping area within 6 4 m 21 ft of any door to a sleeping room the distance measured along a path of travel 3 On every level of a dwelling unit including basements 4 On every level of a residential...

Страница 16: ...ff Blinks On in sync with the 1 beep Condition Originating GAS Alarm Recommendation If hazard is identified take all precautions if an alarm sounds by calling an Emergency Service and getting out of t...

Страница 17: ...enced for a 10 hour period for up to 20 days After 20 days the warning cannot be silenced The alarm should be replaced immediately Silent alarmed previously Off and Blinks On approx every 5 seconds un...

Страница 18: ...ECIFICALLY DISCLAIMS ANY WARRANTY WHETHER EXPRESS OR IMPLIED OF FITNESS FOR A PARTICULAR PURPOSE OTHER THAN THE WARRANTY CONTAINED HEREIN NO IMPLIED WARRANTY ON THIS PRODUCT CREATED BY STATE LAW SHALL...

Отзывы: