The Technical Stuff
__________________________________________________________
- 23 -
Use the following procedure to calibrate the 1176SA stereo adapter:
1.
Remove the signals from both 1176AE units.
2.
Disable gain reduction on each 1176AE by setting both Attack controls fully counterclockwise.
3.
Using two cables with RCA connectors on both ends, connect the 1176-SA to both 1176AEs.
4.
Depress the Meter GR pushbutton.
5.
Adjust the potentiometer on the 1176-SA until both meters read 0dB. If it is not possible to
zero both meters, reverse the stereo interconnect cables and repeat the preceding step.
Changing the Voltage Selector
The 1176AE can operate at 115V or 230V. It will be factory preset for the voltage in your area; however,
if it is necessary to change the voltage selector (located directly below the transformer on the rear
panel), use a small slotted screwdriver to slide it to the desired operating voltage,
NOTE:
When changing operating voltage, the fuse value must be changed as well
.
Make sure the
1176AE is properly set for the voltage in your area before applying AC power to the unit!
Failure to
do so may damage the unit.
Changing Fuses
The AC power fuse is located in the AC power connector block. Remove the power cord before
checking or changing the fuse.
A 125 mA time delay (slow blow) fuse is required for operation at 115 V.
A 63 mA time delay (slow blow) fuse is required for operation at 230 V.
Never substitute different fuses other than those specified here!