5.0 STARTUP
After power is turned on, the LCD shows the startup interface for 10 seconds. UTS40 and UTS62 have the same interface.
Unity UTS40
X1LD041AX17001-1
.V100A00
X1LL020AX26001-1
.V100A00 4
5.1 IDLE
After the startup sequence is complete, the LCD shows the idle interface.Vended and on-premise shown.
Wash Temp: Cold
$: 3.00
Paid: 0.00
5.2 AUTOMATIC RUNNING
5.2.1 Start Automatic Running
On the controller, choose your desired wash temperature, Insert coins (vended model), and then press [Start] button to start
the program.
Auto Stand. Cold
00:32:31
Pre Wash…
5.2.2 Check Running Status Message
Press [Up] and [Down] for 3 seconds to exit the “running” or “Idle” menu. Your password is required to access the run status
menu.
Press [Esc] to return to the “running” or “Idle” menu.
Function Menu
Running Information
Error Check
<Esc>3S=Quit
Lev : 0/ 20cm
Lev: 0/10cm
Temp: 22/40°C
Speed: 50/50RPM
Stand, Cold, Hot
5.2.3 Ending Automatic Running
After completing the cycle, the controller enters the end status mode. The controller beeps to inform the user that the wash
cycle has completed. The buzzer can be cancelled by pressing [Start] button.
WASHER POWER UP
Wash Temp: Cold
FREE MODE