“COMPACTOR FULL” alarm 

will occur.  If necessary, refer to the operation chapter to learn how to adjust this 

time.   

8)   

If you suspect that the ram is moving in the wrong direction go to the display on the hydraulic power 

pack.  Press the 

Up Arrow

 key to go to the manual control page.  Using the 

left and right arrow

 keys you can 

E

xtend and 

R

etract the ram.  If the ram is moving in the wrong direction, reverse the hoses. 

9) 

To connect the wheeled refuse container to the compactor, first shut off power to the system by 

pressing the Red E-

Stop Button on the hydraulic power pack.  Move the container’s open end over the open 

end of the compactor and engage the ratchet hooks into the container rings.  Work the ratchet to bring the 

container to within ½” of the c

ompactor.  

Twist

 the Red E-Stop pushbutton to return power to the system.  

Open the hopper shutoff by withdrawing the red Stop Rod.   

10) 

There is an optional single lever design which is available when side access is at a minimum.  Shut off 

power as before.  Push the latching lever fully to the rear of the compactor to raise the latches.  Roll the 
container against the compactor as close as possible.  Draw the lever forward to latch the hooks on the 
container.  Assure that the hooks are properly engaged.  The lever is then locked by a cam protruding from the 
side of the compactor.  Return power to the system. 

THE COMPACTOR IS NOW READY TO OPERATE 

Chapter 3 - Operation

 

The compactors are designed for loading and compaction of refuse into totally enclosed wheeled containers. 

The specially designed refuse containers, into which refuse is delivered and compacted, are moved from the 
compactor and closed when full.  They can then be rolled to an intermediate storage area or directly to the 
location where a trash truck can unload them. 

The hopper on top of the compactor receives refuse from above and directs it into the compaction chamber.  
A photocell, directed horizontally across the lower portion of this chamber, detects refuse and initiates the 
ram action. 

The hydraulically actuated ram is energized and driven forward for a controlled period to force the refuse into 
the wheeled container which is firmly attached to the compactor.  This action gradually compacts the refuse in 
the container.  The ram continues to travel back and forth, compacting the refuse against the material already 
in the container until the photo eye no longer detects refuse.  The ram will stop in the retracted position.  The 
cycle begins ten seconds after the photo eye continuously sees trash and ends when the photo eye is cleared, 
and the ram returns home. 

When the container is packed to a pre-determined density, the compactor will return home and shut down 
automatically.   The readout states 

“COMPACTOR FULL”

 indicating that the container needs to be switched. 

Prior to operating a compactor, the hopper access door must be closed.  An empty refuse container needs to 
be locked in place.  The wall disconnect must be turned on.  The red Emergency Stop pushbutton must be 

Содержание CP1

Страница 1: ...1 CP1 CP2 COMPACTORS WITH MODEL 20 CONTROLS 525 KENNEDY RD AKRON OHIO 44305 330 733 3996 11 19 21 ...

Страница 2: ...r alignment is corrected After the first 30 minutes the display will read Check Photo Eye and the alarm strobe will flash The alarm display and strobe will continue until the photo eye clears The alarm will not clear during a cool down cycle This operation can be changed from a setup screen so that after the first 30 minutes the compactor shuts down completely and must be manually reset 5 In previ...

Страница 3: ...wheeled refuse containers used in the system The compactor may also be loaded manually Read the entire Installation Chapter before installing the Compactor It is assumed that a specific location for the compactor has already been established with the help of the compactor s representative An experienced outside installation service organization may also be involved in the installation 1 Position t...

Страница 4: ...nnect the hoses already attached to the compactor to the Power Pack The system is designed for hoses 6 to 8 feet long If additional length hoses are required they should be ordered to length and not use fittings to join two hoses together Additional length may also require the system pressure settings to be increased If room temperatures below 60 degrees can be expected the room must be heated The...

Страница 5: ...apter 3 Operation The compactors are designed for loading and compaction of refuse into totally enclosed wheeled containers The specially designed refuse containers into which refuse is delivered and compacted are moved from the compactor and closed when full They can then be rolled to an intermediate storage area or directly to the location where a trash truck can unload them The hopper on top of...

Страница 6: ...left and right arrow keys to extend and retract the ram The ram can be jogged to any position with the resulting required pressure displayed A high pressure alarm will inhibit ram forward The ram can be retracted and then driven forward until high pressure is once again detected If the ram is left in a forward position more than 5 minutes it will automatically be driven home There is a small squar...

Страница 7: ...n the system the startup display will show the word alarm next to a down arrow Pressing the down arrow key will take the client to an alarm display If he presses the down arrow key and no alarm is present the display will read NO ALARM The UP key will return the operator to the startup screen The Top Line of the Alarm Display will have 1 of four messages No Alarm Warning This type of alarm will no...

Страница 8: ...o Reset Low Oil Level Refill reservoir with AW 32 oil 1 To Reset Compactor Full Replace the container 1 To Reset Transducer Error Either the transducer cable has been cut or the transducer has failed Auto Reset Access Door Open As this alarm will clear automatically after the door is reclosed Auto Reset Motor Overload The pump motor starter has tripper because of a current overload Press the blue ...

Страница 9: ...ss the Enter key If this is done properly the serial number for the compactor will be displayed If nothing happens press the UP ARROW KEY to return to the START UP screen and begin the process again In order to verify warranty and to ensure that proper replacement parts are supplied when required each compactor is serialized The serial number allows the manufacturer to track a specific compactor t...

Страница 10: ...points Ram Ext is the time in 1 100 of a second that the ram travels forward at the start of compaction If the time is set too short the compaction will not be maximized If the time is set too long the compactor will reach a mechanical stop and a high pressure COMPACTOR FULL alarm will occur The DOWN ARROW key allows the operator to determine what happens when the photo eye has been blocked more t...

Страница 11: ...tinuous 30 minute run cycle The alarm must be acknowledged 1 TO RESET In a tall building this could eliminate noise at night CHAPTER 4 PERIODIC PREVENTIVE MAINTENANCE Regular periodic attention coupled with a program of preventive maintenance will assure long term trouble free operation WARNING NEVER SERVICE THE COMPACTOR UNLESS THE EMERGENCY STOP PUSHBUTTON IS DEPRESSED AND THE WALL DISCONNECT HA...

Страница 12: ... first password protected display shows the number of machine cycles The hydraulic oil should be drained flushed and refilled with clean oil at least twice a year While the reservoir is empty the suction strainer should be replaced NOTE A certified service representative should carry out this replacement and cleaning procedure CHAPTER 5 TROUBLE SHOOTING SYSTEM IS COMPLETELY DEAD THERE ARE NO LIGHT...

Страница 13: ...ch on the top of the unit For the Chute Source compactor circuit the switch should be in the LO position When the unit is properly aligned all three lights should be on When trash is blocking the photo s line of sight only the yellow should be on RAM DOES NOT COMPLETELY RETURN TO THE RETRACTED POSITION 1 In Manual control extend and retract the ram Watch the pressure readings while the ram is retr...

Страница 14: ...ntainer free of the compactor Close the lid at the end door of the container and move it out of the way D Replace with an empty container E Twist the emergency stop pushbutton to release and press 1 on the alarm screen to reset the compactor full alarm CHAPTER 6 SAFETY CONCERNS The CP1 CP2 C5 compactor is an efficient machine well designed for the purpose intended HOWEVER As with any device of thi...

Страница 15: ...under this Act This obligation must be emphasized It has been ruled that a violation of OSHA standards has been held to be evidence of negligence in a state court ruling against an employer for injury even to a non employee third person ANSI Requirements Z245 1 1984 and A12 1 1973 ANSI Standards American National Standard Institute clearly identify the standards of care and performance that the em...

Страница 16: ...ort 4 Ensuring that access doors are closed and latched before operation may begin 5 Ensuring that the area of operation around the container is clean and clear of persons 6 The compaction Ram produces very large forces that may cause serious bodily injury or damage to property Keep the compactor room locked Be sure that no unauthorized person has access to the room and the equipment in it Equip t...

Страница 17: ...se of the danger from falling glass always wear safety glasses gloves and a hard hat when servicing the compactor 11 If an electrical circuit is fused with a fuse of higher rating than the circuit initially incorporated a serious hazard to life and property may develop 12 Do not permit modifications to the compactor system without first advising the compactor manufacturer and service organizations...

Страница 18: ...18 ...

Отзывы: