Replacing the top shell

1.    Position the top shell over the push button on the 

hearing instrument.

2.   Then push the shell down and back until it snaps 

into place.

Microphone protector replacement

The microphone protector prevents moisture and 
debris damage to the microphone. A clogged 
microphone protector could affect the performance of 
the hearing device. If this occurs, the mic protector can 
be easily replaced.

Removal 

1.   After removing the top shell (shown on previous 

page), remove the microphone protector with a 
tweezer. 
 
 
 

Installation

1.  Place the new mic protector with a tweezer.
2.  Smooth down the mic protector with your finger.
3.  Replace the top shell.

Содержание Moxi 2

Страница 1: ...Moxi2 receiver in canal RIC guide FPO ...

Страница 2: ... xReceivers 6 Choosing the correct coupling for power xReceivers 7 Choosing the correct coupling for super power and super power plus xReceivers 8 Attaching the retention piece to the standard or power xReceiver unit 9 Attaching the dome or sleeve mold to the standard xReceiver unit 10 Attaching the power dome to the power xReceiver unit 10 Attaching the standard power or super power xReceiver uni...

Страница 3: ...ower xReceiver Super power xReceiver Super power plus xReceiver Coupling options Coupling options Coupling options Coupling options Open dome Open dome Closed dome Closed dome cShell cShell 250 500 1000 2000 4000 8000 10 0 10 20 30 40 50 60 70 80 90 100 110 120 Hz Open dome Closed dome Power dome sleeve mold 250 500 1000 2000 4000 8000 10 0 10 20 30 40 50 60 70 80 90 100 110 120 Hz Open dome Close...

Страница 4: ...line on the measurement tool horizontal and level Measuring for an accurate xReceiver unit Choosing the correctxReceiver wire length will ensure a more accurate comfortable fit The measurement tool included in the kit allows for a quickand simple measurement and has the following features Color Code Markings blue left ear and red right ear color code markings to indicate which of the patient s ear...

Страница 5: ...seconds 3 Do not use excessive heat to avoid damage to the electrical components 4 Bend the tubing into the desired shape and hold until it has cooled off Once completely cooled the tube will maintain its new shape 4 Choose the sightline 0 1 2 3 on the measurement tool that is most parallel with the top of the opening of the ear canal In this example the sightline marked 1 would be the most accura...

Страница 6: ...onsiderations Occlusion free Closed dome Choose for Instant fit Semi occluded fit Considerations Extended fitting range over open dome Some occlusion Power dome Choose for Instant fit Occluded fit Considerations Extended low frequency response Occlusion Sleeve mold cShell Choose for Custom fit IntelliVent technology Considerations Comfort Possible occlusion Impression required Poor fit dome too sm...

Страница 7: ...Instant fit Open fit Considerations Occlusion free Closed dome Choose for Instant fit Semi occluded fit Considerations Extended fitting range over open dome Some occlusion Power dome Choose for Instant fit Occluded fit Considerations Extended low frequency response Occlusion Sleeve mold cShell Choose for Custom fit IntelliVent technology Considerations Comfort Possible occlusion Impression require...

Страница 8: ...s page cShell Choose for Custom fit IntelliVent technology Considerations Comfort Possible occlusion Impression required 250 500 1000 2000 4000 8000 10 0 10 20 30 40 50 60 70 80 90 100 110 120 Hz Super power xReceiver Moxi 2 Moxi2 Kiss only 250 500 1000 2000 4000 8000 10 0 10 20 30 40 50 60 70 80 90 100 110 120 Hz Super power plus xReceiver Moxi2 Dura only ...

Страница 9: ...n the patient s requirements The retention piece is optional and allows for extra security in the ear The retention piece can easily be cut shorter to comfortably fit into the patient s concha bowl To attach the retention piece 1 Slide the retention piece over the receiver 2 The retention piece should be secured over the receiver so it appears as one piece ...

Страница 10: ... other hand 2 Slide the appropriate coupling over the receiver 3 The xReceiver unit and coupling should fit snugly together Attaching the power dome to the power xReceiver unit 1 Hold thexReceiver unit in one hand and the power dome in the other hand 2 Slide the power dome over the receiver 3 ThexReceiver unit and power dome should fit snugly together ...

Страница 11: ...iss 1 Use the small silver tool to push the slider pin slightly sideways 2 Place thexReceiver unit on Moxi2 Kiss 3 Use the backof the small silver tool to push in the slider pin Removing thexReceiver unit from Moxi2 Kiss 1 Use the small silver tool to push the slider pin slightly sideways 2 Remove thexReceiver unit ...

Страница 12: ...acing thexReceiver unit from Moxi2 Dura 1 InsertthetoolintotheslottoopenthexReceiverlock 2 Remove thexReceiver unit Attaching the standard power or super power xReceiver unit to Moxi2 Attaching thexReceiver unit to Moxi2 1 Place thexReceiver unit on Moxi 2 2 Place the pin in the hole 3 Usethebackofthesmallsilvertooltopushinthe pin Removing thexReceiver unit from Moxi2 1 Use the small silver tool t...

Страница 13: ... 4 Select the connected tip from the drop down list If applicable choose the appropriate size ofventing 5 If custom shell is selected and has the IntelliVent technology enter the IntelliVent code for optimal venting acoustics The IntelliVent coupling code is inscribed on the custom shell Whenever a change to thexReceiver unit or dome is made during the fitting you need to revisit the Acoustics scr...

Страница 14: ...t necessary to remove the shell Removing the top shell of Moxi2 1 Open the battery door and insert the tool on a slight angle inserting one pin on the side of the tool with the notch inside the battery compartment 2 Twist the tool down in the opposite direction to snap the tool into place 3 Squeeze the tool in the center to push the shell out of the notches 4 Lift the shell up and forward off the ...

Страница 15: ...ts moisture and debris damage to the microphone A clogged microphone protector could affect the performance of the hearing device If this occurs the mic protector can be easily replaced Removal 1 After removing the top shell shown on previous page remove the microphone protector with a tweezer Installation 1 Place the new mic protector with a tweezer 2 Smooth down the mic protector with your finge...

Страница 16: ...on 1 Line up the battery door 2 Insert the pin Use the backof the small silver tool to push the pin in Moxi2 Dura battery door replacement Removal 1 Use the small silver tool to push the pin out 2 Remove the battery door Installation 1 Line up the battery door 2 Insert the pin Use the backof the small silver tool to push the pin in ...

Страница 17: ...ties in the ear canal ThexReceiver kit includes a metal adapter plate that fits on a HA1 coupler and allows for a good connection of thexReceiver unit to the coupler Select ActivateTest BoxMeasurement Mode in UnitronTrueFit software from the menu on the top menu bar Clicking on ActivateTest BoxMeasurement Mode disables the adaptive features and activates the omnidirectional microphone mode to allo...

Страница 18: ... 2 Push the cable down onto the programming port Removal 1 Pull up on the programming cable and remove Moxi2 Dura programming cable Insertion 1 Open the battery door to reveal the programming port 2 Push the cable down onto the programming port Removal 1 Pull up on the programming cable and remove ...

Страница 19: ... 1 Push up on the programming cable 2 Remove the cable Wax guard replacement and cleaning domes AllxReceiver units are equipped with a waxguard system to protect thexReceiver from ear wax The wax guard can be easily replaced You will need to counsel your patient on how to replace the waxprotector see instructions included with the replacement packs If necessary the domes andxReceiver units can be ...

Страница 20: ...orway 47 23 00 32 70 Russia 7 495 788 02 04 South Africa 011 467 7662 52 South Korea 82 10 3414 8366 Spain 34 902 494 960 Sweden 46 0 8 546 20 960 Switzerland 0800 928 801 U K 01925 247810 U S 1 800 888 8882 20 Beasley Drive P O Box 9017 Kitchener ON N2G 4X1 Canada 13 026 029 5936 02 At Unitron we care deeply about people with hearing loss We workclosely with hearing healthcare professionals to pr...

Отзывы: