2 Mechanical Installation
P3 240-840A
9
M
o
u
n
ti
n
g
Air flow direction
Ambient temperature
0 bis <45°C
(reduced, up to 60°C)
max. Cooling unit temperature
80°C
(internal watchdog)
Air-mass throughput
240A
680m³h
360A
680m³h
480A
820m³h
840A
820m³h
Dissipation loss with max. power
Unit P3-x/x-
Unit W
Mains choke W
240A- 1000
260
360A- 1440
330
480A- 1890
400
840A- 3060
780