3 Electrical Installation
P3 240-840A
25
Si
g
n
a
ls
BTB signal - Drive ready
BTB signal
X3:25
>+5V
Error
X3:25
<+5V
Error
Voltage error
24V, 15V, 5V
saved
Phase error, rotating field
saved
Defective input fuse
saved
Over-temperature
saved
In case of errors or failure the power section is immediately internally disabled
without delay.
To clear the saved error re-enable the drive (switch off/on or reset key)
Measurements
Measurement advice
Measuring instruments:
multimeters for current
and voltage
shunt or clamp-on ammeter
Measuring faults:
mean value > actual value
acc. to the form factor
approx. 1 to 5%
Measured values
with a positive command value
Voltage:
X10:10 negative
X10:13 positive
max 1.15 x power supply
For 400V
~
>>>
460V=
Current:
ammeter in the motor circuit
5s 200%, continuously 110% type current
Measured values across REG4
(selectable, see Manual REG4)
Speed
X2:109
-
5V or
-
10V
for 100% speed
Current
X2:111
-
5V or
-
10V
for 200% current
GND
X2:104