Data presented here is the best available at the
time of publicaton. United Industries and/or its
representatives assume no liability for its use.
Series
TFH
For
SEASONAL SHUTDOWN
of the TOWER-FLO
®
Filter System:
1.
ELECTRICAL:
Disconnect electrical power.
2.
PUMP:
Drain liquid from the pump through the plug at bottom front section of volute. Addition of a good rust
inhibitor into liquid end of the pump is recommended to prevent corrosion. Be sure the motor is kept dry and cov-
ered.
3.
VESSEL & VALVES:
Drain vessel and valves by removing the drain plug in the bottom of the vessel.
4.
GAUGES & DIFFERENTIAL PRESSURE SWITCH:
Disconnect influent and effluent pressure lines at facepiping
and allow to drain, then reconnect.
For
YEAR-ROUND OPERATION
of the TOWER-FLO Filter System:
In installations where freezing may occur, heat tracing of all slow moving or static lines, especially tubing to pres-
sure gauges and differential pressure switch, is highly recommended. Use standard insulation and freeze protec-
tion methods for your region.