This manual describes the installation and operation of the Vogelzang, VG5780 wood heater. This heater meets the 2020 

U.S. Environmental Protection Agency’s crib wood emission limits for wood heaters sold after May 15, 2020. Under specific 

test conditions this heater has been shown to deliver heat at rates ranging from 12,293 to 26,386 Btu/hr. This heater 

achieved a particulate emissions rate of 1.3 g/hr when tested to method ASTM E2779-10 (*and an efficiency of 72%).

• 

IMPORTANT:  Read this entire manual before installing 

and operating this product.  Failure to do so may result 

in property damage, bodily injury, or even death.  

Proper installation of this stove is crucial for safe and 

efficient operation.

• 

Install  vent  at  clearances  specified  by  the  vent 

manufacturer.

•  Do not connect the pellet vent to a vent serving any 

other appliance or stove.

• 

Do  not  install  a  flue  damper  in  the  exhaust  venting 

system of this unit.

• 

Use of outside air is not required for this unit.

• 

Contact  your  local  building  officials  to  obtain  a 

permit and information on any additional installation 

restrictions or inspection requirements in your area.

•  Do not throw this manual away.  This manual has 

important operating and maintenance instructions 

that you will need at a later time.  Always follow the 

instructions in this manual.

• 

This appliance is designed for the use of pelletized fuel 

that  meet  or  exceed  the  standard  set  by  the  Pellet 

Fuel Institute(PFI).

•  Never use gasoline, gasoline-type lantern fuel, 

kerosene,  charcoal  lighter  fluid,  or  similar  liquids  to 

start or ’freshen up’ a fire in this stove.  Keep all such 

liquids well away from the stove while it is in use.

• 

A  working  smoke  detector  must  be  installed  in  the 

same room as this product.

• 

Install a smoke detector on each floor of your home; 

incase of accidental fire from any cause it can provide 

time for escape.

• 

The smoke detector must be installed at least 15 feet 

(4,57 M) from the appliance in order to prevent undue 

triggering of the detector when reloading.

•  Do not unplug the stove if you suspect a malfunction.  

Turn the ON/OFF SWITCH to ”OFF’ and contact your 

dealer.

• 

Your  stove  requires  periodic  maintenance  and 

cleaning (see ”MAINTENANCE ”). Failure to maintain 

your  stove  may  lead  to  improper  and/or  unsafe 

operation.

•  Disconnect the power cord before performing any 

maintenance!    NOTE:  Turning  the  ON/OFF  Switch  to 

”OFF” does not disconnect all power to the electrical 

components of the stove.

•  Never try to repair or replace any part of the stove 

unless instructions for doing so are given in this manual.  

All other work should be done by a trained technician.

•  Do not operate your stove with the viewing door 

open.  The auger will not feed pellets under these 

circumstances and a safety concern may arise from 

sparks or fumes entering the room.

• 

Allow  the  stove  to  cool  before  performing  any 

maintenance  or  cleaning.    Ashes  must  be  disposed 

in a metal container with a tight fitting lid.  The closed 

container of ashes should be placed on a non-

combustible surface or on the ground, well away from 

all combustible materials, pending final disposal.

• 

The  exhaust  system  should  be  checked  monthly 

during the burning season for any build-up of soot or 

creosote.

• 

Do not touch the hot surfaces of the stove.  Educate 

all children on the dangers of a high-temperature 

stove. Young children should be supervised when they 

are in the same room as the stove.

• 

The hopper and stove top will be hot during operation; 

therefore, you should always use some type of hand 

protection when refuelling your stove.

• 

A power surge protector is required.  This unit must be 

plugged into a 110 - 120V, 60 Hz grounded electrical 

outlet. Do not use an adapter plug or sever the 

grounding plug. Do not route the electrical cord 

underneath, in front of, or over the heater.  Do not 

route the cord in foot traffic areas or pinch the cord 

under furniture.

•  The heater will not operate during a power outage. 

If a power outage does occur, check the heater for 

smoke spillage and open a window if any smoke spills 

into the room.

•  The feed door must be closed and sealed during 

operation.

• 

Never block free airflow through the open vents of the 

unit.

• 

Keep foreign objects out of the hopper.

•  The moving parts of this stove are propelled by high 

torque electric motors.  Keep all body parts away from 

the auger while the stove is plugged into an electrical 

outlet.  These moving parts may begin to move at any 

time while the stove is plugged in.

• 

Do not place clothing or other flammable items on or 

near this stove.

• 

When installed in a mobile home, the stove must be 

grounded directly to the steel chassis and bolted to 

the floor.  WARNING—THIS UNIT MUST NOT BE INSTALLED 

IN THE BEDROOM (per HUD requirements).  CAUTION—

The structural integrity of the mobile home floor, wall, 

and ceiling/roof must be maintained.

•  This appliance is not intended for commercial use.

• 

CAUTION:  Burning  fuel  creates  carbon  monoxide 

and can be hazardous to your health if not properly 

vented.

*This appliance is a freestanding heater.  It is not intended to be attached to any type of ducting.  It is not a furnace.

Safety Precautions

Содержание VOGELZANG VG5780

Страница 1: ...STRUCTIONS THIS MANUAL WILL HELP YOU TO OBTAIN EFFICIENT DEPENDABLE SERVICE FROM THE HEATER AND ENABLE YOU TO ORDER REPAIR PARTS CORRECTLY KEEP IN A SAFE PLACE FOR FUTURE REFERENCE CALIFORNIA PROPOSIT...

Страница 2: ...to repair or replace any part of the stove unless instructions for doing so are given in this manual All other work should be done by a trained technician Do not operate your stove with the viewing d...

Страница 3: ...Your pellet stove is designed to burn premium hardwood pellets that comply with the Pellet Fuel Institute PFI minimum of 40 lbs density per cubic ft 1 4 to 5 16 diameter length no greater than 1 5 no...

Страница 4: ...de Wall to Vent Pipe 12 305 C Back Wall to Stove 12 305 D Back Wall to Vent Pipe 3 77 E Ceiling to Floor 84 2134 F Ceiling to Stove 46 875 1191 CORNER CLEARANCES G Side Wall to Stove 10 254 H Side Wal...

Страница 5: ...tions PELLET VENT TYPE A UL listed 3 inch or 4 inch type PL pellet vent exhaust system must be used for installation and attached to the pipe connector provided on the back of the stove use a 3 inch t...

Страница 6: ...grade when adjacent to public walkways E Minimum 2 foot 0 61m clearance above any grass plants or other combustible materials F Minimum 3 foot 0 91m clearance from an forced air intake of any applianc...

Страница 7: ...ire harnesses as shown Step 2 Unpack the top mount controls and ensure that the wiring harness shown is attached securely Step 3 Connect the factory installed wiring harnesses to the control panel as...

Страница 8: ...on can be used if your heater is below ground level by simply adding the clean out section and vertical pipe inside until ground level is reached With this installation you have to be aware of the sno...

Страница 9: ...e floor to your stoves inlet exhaust pipes are approximate and may vary depending on your installation TYPICAL FRESH AIR TERMINATION EXHAUST INLET LOCATIONS OUTSIDE AIR SUPPLY OPTIONAL UNLESS INSTALLI...

Страница 10: ...n changes the two digit display from degrees Celsius to degrees Fahrenheit D MODE M T BUTTON The Mode of the stove can be switched between manual and controlled with a Thermostat Separate LEDs to the...

Страница 11: ...troduced by hand will not increase heat output but may seriously impair the stoves performance by generating considerable smoke Do not burn wet pellets The stove s performance depends heavily on the q...

Страница 12: ...e towards the right Through trial and error you will find the best setting Consult your dealer if you need help NOTE On heat range 1 damper should be either completely closed or open no more than a 1...

Страница 13: ...ed with a brush specifically designed for the type of chimney in use A qualified chimney sweep can perform this service It is also recommended that before each heating season the entire system be prof...

Страница 14: ...lower front corners of the heat exchanger To access these clean outs you must remove both side panels The clean outs are secured to the firebox with 2 5 16 screws Remove the clean outs and vacuum out...

Страница 15: ...smoke and CO monitors in areas having the potential to generate CO CHECK AND CLEAN THE HOPPER Check the hopper periodically to determine if there is any sawdust fines that is building up in the feed s...

Страница 16: ...ake sure that they are working properly This is also a good time to give the entire stove a good cleaning throughout SPRING SHUTDOWN After the last burn in the spring remove any remaining pellets from...

Страница 17: ...ons to operate this wood heater in a manner inconsistent with operating instructions in this manual Trouble Shooting Guide Display is Flashing E1 Possible Causes Possible Remedies Unplug stove first w...

Страница 18: ...the gray wires to the air switch Combustion blower failure With the stove on check to see if the combustion blower is running If it is not you will need to check for power going to the combustion blo...

Страница 19: ...n then remove the two bolts that hold the auger bracket to the auger tube The auger bracket will now be able to be removed form the auger tube Remove the two bolts on the side of the auger tube to rem...

Страница 20: ...r for secure connections Use a continuity tester to test the hopper safety switch replace if necessary The auger shaft is jammed Start by emptying the hopper Then remove the auger motor by removing th...

Страница 21: ...ll Coming Back Into The Home Possible Causes Possible Remedies Unplug stove first when possible There is a leak in the vent pipe system Inspect all vent pipe connections Make sure they are sealed with...

Страница 22: ...jam Loose wire or connector Check all wires and connectors that connector to the auger motor high limit switch and the Molex connector Bad control board If the fuse is good the wires and connectors c...

Страница 23: ...Remove the burnpot and thoroughly clean it Air damper is broken Visually inspect the damper assembly Make sure the damper plate is attached to the damper rod When the damper rod is moved the plate sho...

Страница 24: ...24 Replacement Parts 1 5 2 7 8 28 29 30 31 32 9 11 10 16 13 12 14 15 18 17 23 25 24 26 33 27 20 19 21 22 3 4 6...

Страница 25: ...haust 1 11 892187 Auger 1 12 891132 Auger Bushing 1 13 892776 Vented Back Panel 1 14 80709 Convection Blower 1 15 80455 High Limit T disc 1 16 80549 Vacuum Switch 1 17 80602 Exhaust Blower 1 18 88166...

Страница 26: ...26 Wiring Diagram 1 25A 250V FUSE 7 5A 250V FUSE CORRECT WRONG Ensure the wires are connected to the bottom two prongs of the hopper switch as shown...

Страница 27: ...27 Notes...

Страница 28: ...07 Date _____________________ Engineer Name ________________________________ License No ____________________________________ Company _____________________________________ Telephone No _______________...

Страница 29: ...S UN ENDROIT SUR POUR VOUS Y REFERER LORSQUE VOUS NOUS CRIVEZ VEUILLEZ INDIQUER LE NUM RO COMPLET DU MOD LE AFFICH SUR LA PLAQUE SIGNAL TIQUE DE L APPAREIL DE CHAUFFAGE LORSQUE VOUS COMMANDEZ DES PIEC...

Страница 30: ...____________________________ Service de 07 Date _____________________ Nom de l ing nieur ____________________________ N de licence _________________________________ Compagnie _________________________...

Страница 31: ...26 1 25A 250V Fusible 7 5A 250V Fusible Sch ma De C blage CORRECT FAUX Assurez vous que les fils sont connect s aux deux broches inf rieures de l interrupteur de la tr mie comme illustr...

Страница 32: ...1 12 891132 Douille de vis sans fin 1 13 892776 Panneau arri re ventil 1 14 80709 Ventilateur convection 1 15 80455 Disque T haute limite 1 16 80549 Commutateur de vide 1 17 80602 Ventilateur d chappe...

Страница 33: ...24 Pi ces De Rechange 1 5 2 7 8 28 29 30 31 32 9 11 10 16 13 12 14 15 18 17 23 25 24 26 33 27 20 19 21 22 3 4 6...

Страница 34: ...utilis s est peut tre de mauvaise qualit Si possible essayez une autre marque de granul s Essayez aussi une marque compos e d un autre type de bois r sineux plut t que feuillus Des bois diff rents pr...

Страница 35: ...tari re et essayez de le faire fonctionner Si le moteur tourne c est l arbre qui est coinc sur quelque chose Si le moteur ne tourne pas il est d fectueux Tari re bloqu e Commencez par vider la tr mie...

Страница 36: ...ande n envoie pas de courant l allumeur V rifiez la tension qui arrive l allumeur lors du d marrage Ce doit tre la tension nominale Si la tension est inf rieure la valeur nominale v rifiez le c blage...

Страница 37: ...testeur de continuit pour tester l interrupteur de s curit de la tr mie remplacer le si n cessaire L arbre de la tari re est coinc Commencez par vider la tr mie Puis retirez le moteur de la tari re en...

Страница 38: ...le moteur de la tari re en retirant la goupille de la tari re puis retirez les deux boulons qui fixent le support de tari re au tube de tari re Vous pouvez maintenant retirer le support du tube de ta...

Страница 39: ...ateur de combustion Lorsque le po le est en marche v rifiez si le ventilateur de combustion est en fonctionnement Sinon v rifiez l alimentation lectrique du ventilateur de combustion Ce doit tre la te...

Страница 40: ...rchauffe et d clenche l arr t de temp rature interne Enlevez la poussi re des bobinages et pales de ventilateur Si le graissage du ventilateur ne suffit pas il se peut que le ventilateur soit d fectue...

Страница 41: ...saison de chauffage v rifiez que la zone l ext rieur des syst mes d vacuation et d admission d air ne soit pas obstru e Nettoyez et retirez les cendres volantes du syst me d vacuation Nettoyez tous l...

Страница 42: ...diam tre JOINTS DE PORTE ET DE VITRE Inspecter r guli rement les principales portes et fen tres en verre joints La porte principale peut avoir besoin d tre enlev pour avoir des joints effiloch s bris...

Страница 43: ...oins avant inf rieurs de l changeur de chaleur Pour acc der ces outs propres vous devez retirer les deux panneaux lat raux Les sorties propres sont fix es la chambre de combustion avec 2 vis 5 16 Reti...

Страница 44: ...arri re ou d ouvrir le syst me d vacuation pour toute t che d inspection de nettoyage ou d entretien Ne proc dez jamais l inspection au nettoyage ou l entretien sur un po le chaud N utilisez pas le p...

Страница 45: ...re vers la gauche En r gle g n rale en cas de r glage pour une faible vitesse d alimentation le registre doit tre r gl vers la gauche dans le sens de fermeture Pour une vitesse d alimentation lev e le...

Страница 46: ...lation des codes du b timent pour lesquels le po le a t approuv et cela annulerait toutes les garanties La conception du po le int gre l alimentation automatique des granul s dans le feu selon un ryth...

Страница 47: ...rres passant du niveau 1 au niveau 5 de chauffage C TOUCHE C F La touche C F fait passer l affichage deux chiffres des degr s Celsius aux degr s Fahrenheit et vice versa D TOUCHE MODE M T Le Mode de f...

Страница 48: ...aussi court et rectiligne que possible et doit s adapter par dessus et non pas l int rieur du branchement d air ext rieur du po le CONDITIONS SPECIALES D INSTALLATION DANS UNE MAISON MOBILE Avertisse...

Страница 49: ...ction de nettoyage et un tuyau vertical l int rieur jusqu au niveau du sol Avec cette installation il faut tenir compte de la ligne de cong re des herbes et des feuilles mortes Nous recommandons une l...

Страница 50: ...de toiture ou surplombs H D gagement minimum de 1 pi 0 3 m l horizontale de tout mur en mat riau combustible I Doit se trouver au minimum 3 pi 0 91 m au dessus du toit et 2 pi 0 61 m au dessus de tout...

Страница 51: ...si l installation se trouve plus de 2 500 pi 762 m d altitude Nous recommandons l utilisation de conduits Simpson Dura Vent ou Metal Fab si vous utilisez d autres tuyaux consultez les codes de constr...

Страница 52: ...gistre de tirage sur le syst me d vacuation de cet appareil Les directives d installation ci dessous doivent tre respect es pour garantir la conformit tant avec la liste de s curit de ce po le qu avec...

Страница 53: ...fabricant ne pourra tre tenu pour responsable des dommages caus s par le mauvais fonctionnement d un po le d une mauvaise vacuation ou installation Pour toute question appelez le 800 750 2723 et ou c...

Страница 54: ...ourrait provoquer un incendie de maison Ne pas sur le feu ou utiliser des combustibles volatiles ou combustibles cela peut causer un danger de dommages personnels et mat riels SECURITE ET CONFORMITE E...

Страница 55: ...pas enti rement l alimentation des composants lectriques du po le Ne tentez jamais de r parer ou de remplacer une pi ce du po le sauf indication contraire dans les directives de ce guide Tous les aut...

Страница 56: ...reil n a pas t con u pour tre utilis en tant que source principale de chaleur Certifi selon la norme ASTM E1509 12 2017 et Certifi ULC S627 2000 et UM 84 HUD US Environmental Protection Agency Certifi...

Отзывы: