background image

22

© 2021 United States Stove Company

It is recommended that your heating system is serviced regularly and that the appropriate Service Interval Record is 

completed.

SERVICE PROVIDER

Before completing the appropriate Service Record below, please ensure you have carried out the service as described in 

the manufacturer’s instructions. Always use the manufacturer's specified spare part when replacement is necessary.

Service 01

 Date: ______________________

Engineer Name: ____________________________________
License No.: ________________________________________
Company: __________________________________________
Telephone No.: _____________________________________
Stove Inspected:              Chimney Swept:    
Items Replaced: ____________________________________

Service 03

 Date: ______________________

Engineer Name: ____________________________________
License No.: ________________________________________
Company: __________________________________________
Telephone No.: _____________________________________
Stove Inspected:              Chimney Swept:    
Items Replaced: ____________________________________

Service 05

 Date: ______________________

Engineer Name: ____________________________________
License No.: ________________________________________
Company: __________________________________________
Telephone No.: _____________________________________
Stove Inspected:              Chimney Swept:    
Items Replaced: ____________________________________

Service 07

 Date: ______________________

Engineer Name: ____________________________________
License No.: ________________________________________
Company: __________________________________________
Telephone No.: _____________________________________
Stove Inspected:              Chimney Swept:    
Items Replaced: ____________________________________

Service 02

 Date: ______________________

Engineer Name: ____________________________________
License No.: ________________________________________
Company: __________________________________________
Telephone No.: _____________________________________
Stove Inspected:              Chimney Swept:    
Items Replaced: ____________________________________

Service 04

 Date: ______________________

Engineer Name: ____________________________________
License No.: ________________________________________
Company: __________________________________________
Telephone No.: _____________________________________
Stove Inspected:              Chimney Swept:    
Items Replaced: ____________________________________

Service 06

 Date: ______________________

Engineer Name: ____________________________________
License No.: ________________________________________
Company: __________________________________________
Telephone No.: _____________________________________
Stove Inspected:              Chimney Swept:    
Items Replaced: ____________________________________

Service 08

 Date: ______________________

Engineer Name: ____________________________________
License No.: ________________________________________
Company: __________________________________________
Telephone No.: _____________________________________
Stove Inspected:              Chimney Swept:    
Items Replaced: ____________________________________

SERVICE RECORD

Содержание KP130

Страница 1: ...lding or fire officials about permits restrictions and installation requirements in your area NEVER OPERATE THIS PRODUCT WHILE UNATTENDED CAUTION Please read this entire manual before you install or u...

Страница 2: ...s burning wood pellet fuel this heater has been shown to deliver heat at a rate of 8 932 to 25 701 Btu hr This heater achieved a particulate emissions rate of 1 3 g hr when tested to method ASTM E 277...

Страница 3: ...and_____________________________________________ If no Date of inspection of existing venting system ________________________________________________________________ COMMISSIONING Confirm Hearth Pad I...

Страница 4: ...OR IS REQUIRED THIS UNIT MUST BE PLUGGED INTO A 110 120V 60 HZ GROUNDED ELECTRICAL OUTLET DO NOT USE AN ADAPTER PLUG OR SEVER THE GROUNDING PLUG DO NOT ROUTE THE ELECTRICAL CORD UNDERNEATH IN FRONT OF...

Страница 5: ...behind the stove Floor protection must extend under and 2 51 mm to each side of the chimney tee for an interior vertical installation A Floor Protector of 1 26 mm thick is recommended for this instal...

Страница 6: ...ate paint or protective coating to ensure grounding Vent must be 3 or 4 inch PL Vent and must extend a minimum or 36 914 mm above the roof line of the mobile home and must be installed using a certifi...

Страница 7: ...pellet vent pipe is not furnished with the unit and must be purchased separately PELLET VENT INSTALLATION The installation must include a clean out tee to enable collection of fly ash and to permit pe...

Страница 8: ...d void your warranty HORIZONTAL EXHAUST VENT INSTALLATION 1 Locate your pellet stove in a location which meets the requirements of this manual but in an area where it does not interfere with the house...

Страница 9: ...o get above the snowdrift line This same installation can be used if your heater is below ground level by simply adding the clean out section and vertical pipe inside until ground level is reached Wit...

Страница 10: ...ll with too much fuel and the fire will smother out To much air will result in a flame that is overactive or aggressive The flame in this situation is typically very blue at the bottom and resembles a...

Страница 11: ...ordance to the heat range setting However this speed can be manually operated by pressing the Draft Fan arrows up or down Draft Fan when pressed the display will show Df A which is automatic Press the...

Страница 12: ...the stove cycle between the preselected desired heat range setting 1 to 5 and the minimum heat range setting of 1 The T Stat will not turn the stove on and off When the desired room temperature has be...

Страница 13: ...reduced performance Store your pellets in a dry place DO NOT store the fuel within the installation clearances of the unit or within the space required for refuelling and ash removal Doing so could re...

Страница 14: ...RN MAY ARISE FROM SPARKS OR FUMES ENTERING THE ROOM THE DOOR MUST BE CLOSED AND SEALED DURING OPERATION If the door is opened while the stove is in operation it must be closed within 30 seconds or the...

Страница 15: ...cally remove and clean the burn pot and the area inside the burn pot housing In particular it is advisable to clean out the holes in the burn pot to remove any build up that may prevent air from movin...

Страница 16: ...rush specifically designed for the type of chimney in use A qualified chimney sweep can perform this service It is also recommended that before each heating season the entire system be professionally...

Страница 17: ...gloves carefully remove any loose pieces of glass from the door frame 4 Replace the glass and gasket making sure the gasket runs the full perimeter of the glass edge 5 Re install the retainer and eigh...

Страница 18: ...d or replace door gaskets Check that all outside connections are clear of any obstructions Check the exhaust system clean as needed Checkthatthepressureswitchconnectiontothefireboxisfreeofashorclearof...

Страница 19: ...he stove is in the Shut Down state waiting for the off button or for a 15 minute period after the stove was turned off or for the stove to cool down or for the door to be closed Flashing dash in Heat...

Страница 20: ...Clear Glass 1 3 88324 1 Rope Gasket 1 4 69762 Burnpot Assembly 1 5 80780 IR Remote 1 6 88168 Burnpot Housing Gasket 1 7 80778 Circuit Board Assy 1 8 88117 Exhaust Duct Gasket 1 9 88118 Ignitor Flange...

Страница 21: ...s are ordered Before contacting customer service write down the model number and the serial number of this unit That information can be found on the certification label attached to the back of the uni...

Страница 22: ..._____ Engineer Name _____________________________________ License No _________________________________________ Company ___________________________________________ Telephone No ________________________...

Страница 23: ...2021 United States Stove Company 23 NOTES...

Страница 24: ...24 2021 United States Stove Company NOTES...

Страница 25: ...2021 United States Stove Company 25 NOTES...

Страница 26: ..._____________________ Service de 07 Date ______________________ Nom de l ing nieur _________________________________ N de licence ______________________________________ Compagnie _____________________...

Страница 27: ...RIQUE BLANC NOIR PCB ALLUMEUR PRESSOSTAT MARRON MARRON NOIR BLANC ROUGE BLEU ORANGE PRISE MOLEX AU CIRCUIT IMPRIM PCB PRINCI PAL NOIR NOIR NOIR BLANC BLANC SOUFFLANTE DE DISTRIBUTION VENTILATEUR D VAC...

Страница 28: ...rcuit Board Assy 1 8 88117 Joint de conduit d chappement 1 9 88118 Joint de bride d allumage 1 10 80607 Cartouche d allumage 1 11 80549 Pressostat 1 12 80472 Ventilateur de distribution 1 13 88106 Joi...

Страница 29: ...t deux fois par seconde Cela indique que le po le fonctionne normalement et qu une condition de temp rature excessive existe provoquant l arr t du combustible Indicateur de r glage du niveau de chaleu...

Страница 30: ...st me vis sans fin est bloqu ou il y a une vo te de combustible dans la tr mie qui emp che le combustible de s couler dans le syst me d approvisionnement vis sans fin PROBL ME CAUSE L allumeur automat...

Страница 31: ...re sont sp cifiques votre appareil Lors de la commande de pi ces de rechange les informations contenues dans ce manuel vous aideront vous assurer que les bons articles sont command s Avant de contacte...

Страница 32: ...verre N UTILISEZ PAS de nettoyants abrasifs N effectuez PAS le nettoyage lorsque la vitre est CHAUDE N essayez pas de faire fonctionner l appareil avec du verre bris Le verre de remplacement peut tre...

Страница 33: ...p cialement con ue pour le type de chemin e utilis Un ramoneur qualifi peut fournir ce service Il est galement conseill d inspecter de nettoyer et si n cessaire de r parer la totalit du syst me avant...

Страница 34: ...int et la mention E2 s affiche sur l cran deux chiffres Le po le doit s arr ter compl tement avant de pouvoir tre red marr CHAMBRES INT RIEURES Pot de combustion Retirez et nettoyez p riodiquement le...

Страница 35: ...le voyant vert s allume 3 Ajustez la vitesse d alimentation au r glage souhait en appuyant sur le bouton Avance du niveau de chaleur Si le feu ne d marre pas dans 12 minutes appuyez sur Marche Arr t...

Страница 36: ...inf rieur 300 parties par million Les granul s mous contenant une quantit excessive de sciure de bois en vrac qui ont t ou sont mouill s r duiront les performances Rangez vos pellets dans un endroit...

Страница 37: ...entre le r glage pr s lectionn de la plage de chaleur d sir e 1 5 et le r glage de la plage de chaleur minimale de 1 Le T Stat n allumera ni ne teindra le po le Lorsque la temp rature ambiante souhai...

Страница 38: ...de chaleur Cependant cette vitesse peut tre r gl e manuellement en appuyant sur les fl ches haut et bas du ventilateur de tirage Draft Fan Lorsque le bouton Draft Fan ventilateur de tirage est appuy...

Страница 39: ...ant une dur e suffisante le pot de combustion se remplira avec trop de combustible et le feu s touffera Trop d air provoquera une flamme hyperactive ou agressive La flamme dans cette situation est g n...

Страница 40: ...chutes de neige il est recommand que l installation soit plus grand que 3 pieds 0 91 m pour obtenir au dessus de la ligne de cong re Cette m me installation peut tre utilis e si votre chauffe eau est...

Страница 41: ...re garantie ECHAPPEMENT HORIZONTALES INSTALLATION 1 Localisez votre po le granul s dans un endroit qui r pond aux exigences de ce manuel mais dans une zone o il ne g ne pas la charpente de la maison l...

Страница 42: ...volantes et pour permettre le nettoyage p riodique du syst me d chappement Les coudes 90 degr s accumulent les cendres volantes et la suie r duisant ainsi le d bit d chappement et les performances du...

Страница 43: ...e la maison mobile et doit tre install l aide d un coupe feu de plafond certifi et d un chapeau de pluie Lors du d m nagement de votre maison mobile toute ventilation ext rieure doit tre enlev e penda...

Страница 44: ...grand pour s tendre sur au moins 6 po 153 mm l avant 6 po 153 mm de chaque c t et 1 po 26 mm derri re le po le La protection du plancher doit s tendre sous et 2 po 51 mm de chaque c t du t de chemin...

Страница 45: ...E PRISE ET NE COUPEZ PAS LA FICHE DE TERRE N ACHEMINEZ PAS LE CORDON LECTRIQUE SOUS DEVANT OU SUR LE PO LE NE FAITES PAS COURIR LE CORDON LECTRIQUE DANS LES ZONES DE PASSAGE ET NE LE COINCEZ PAS SOUS...

Страница 46: ...n date d inspection du syst me de ventilation existant ___________________________________________________________________ MISE EN SERVICE Confirmer l installation du tapis de foyer conform ment aux i...

Страница 47: ...Pellet peut effectuer le taux r el d alimentation en carburant et de br ler fois Taux d alimentation en carburant peut varier par autant que 20 Utiliser PFI carburant list pour de meilleurs r sultats...

Страница 48: ...fortune lors de l installation de ce radiateur Contactez les responsables locaux du b timent ou des pompiers pour conna tre les permis les restrictions et les exigences d installation dans votre r gio...

Отзывы: