Your Supplemental Furnace is designed to be

a supplemental or central heating source for your
home. This solid fuel furnace may be installed in
conjunction with a properly operating central fur-
nace that is listed or certified in accordance with
nationally recognized safety standards and
equipped with the required controls and other
safety features and which has been installed with
appropriate standards of  National Fire Protection
Association with  installation clearances specified
in the furnace nameplate marking. The installation
must be   accomplished by a qualified agency (one
who is engaged in, and is responsible for, or is
thoroughly familiar with the installation and   opera-
tion of the gas, oil, and solid fuel burning heating
appliances, who is experienced in such work,
familiar with all precautions required, and has
complied with all the requirements of the authority
having jurisdiction.) The installation shall be in
strict accordance with the manufacturer's installa-
tion instructions furnished with the solid fuel fur-
nace.

The chimney connector of the furnace is to be

installed to provide clearances to combustible
material not less than specified in the individual
classifications and marked on the furnace. The
chimney connector must be connected to a    chim-
ney suitable for use with residential type or building
heating appliances which burn solid fuel.

The furnace is designed to operate in either

parallel or series air flow arrangement with the
central furnace or as a central furnace.

HOW THE FURNACE FUNCTIONS

Your Furnace is designed to be installed in a parallel air flow arrangement with a gas or oil-fired
forced air upflow-type central furnace, or it may be installed as a central furnace.

CARING FOR PAINTED PARTS - This furnace has a painted outside jacket, which is durable but it
will not stand rough handling or abuse. When installing you furnace, use care in handling. Clean with
soap and warm water when furnace is not hot. DO NOT use any acids or scouring soap, as these
wear and dull the finish. DISCOLORATION WILL OCCUR IF THE FURNACE IS OVERFIRED.
FOLLOW OPERATING INSTRUCTIONS CAREFULLY.

Keep the feed and ash doors closed at all times except while tending the furnace.

14.

15.

RULES FOR SAFE INSTALLATION AND OPERATION

PARALLEL INSTALLATION: The design is such
that when the blower comes on, the blower on the
central system also comes on.

The blower will only come on when the

temperature in the plenum has reached the  setting
on the blower control. This is to insure that there is
sufficient warm air in the system to make it
efficient for the unit to operate. When the central
system thermostat calls for heat, the central sys-
tem will operate by the burner igniting and the
blower coming on. It is possible that both systems
will operate simultaneously. It is recommended
that for the most efficient use of your
Supplemental Furnace, that it be fired as much as
possible in order to reduce the demand on your
existing central heating system.

The warm air supply outlet of the

supplementary furnace shall not be connected to
the cold air return inlet of the central furnace
because the possibility exists of components of
the central furnace overheating and causing the
central furnace to operate other than is intended.

CENTRAL FURNACE INSTALLATION: As a cen-
tral furnace, the unit functions independently of
any other system. The blower will come on when
the plenum temperature reaches the     setting on
the blower control.

Содержание HOTBLAST 1200G

Страница 1: ...E U S ONLY FOR INSTALLATION AS A CENTRAL FURNACE DO NOT USE THIS FURNACE IN A MOBILE HOME OR TRAILER Improper Installation May Void Your Warranty Save This Manual For Future Reference CAUTION Read All...

Страница 2: ...ing Masonry Chimney SEE Page 8 Electrical Wiring 6 Draft Regulator 1 2 Conduit Conduit Connectors Furnace Cement Manufacturer Recommends Rutland Black Code 78 or Equivalent Plenum and Duct Work as Req...

Страница 3: ...operly installed a house fire may result For your safety follow the in stallation directions Contact local building or fire officials about restrictions and installation in spection requirements in yo...

Страница 4: ...st have free access to the room CAST IRON PARTS MUST BE SEASONED TO AVOID CRACKING BUILD ONLY SMALL FIRES ON FIRST USE To prevent injury do not allow anyone to use this furnace who is unfamiliar with...

Страница 5: ...as or oil fired forced air upflow type central furnace or it may be installed as a central furnace CARING FOR PAINTED PARTS This furnace has a painted outside jacket which is durable but it will not s...

Страница 6: ...6 DRAWINGS FOR ILLUSTRATION PURPOSES ONLY MODEL 1200G DIMENSIONS FIG 1...

Страница 7: ...305 mm Unit to backwall 30 760 mm Chimney connector pipe to sidewall 21 530 mm Chimney connector pipe to backwall 18 460 mm Hot air ducts to combustibles 6 150 mm NOTE Install only on a noncombustible...

Страница 8: ...e flue liner to be sure it is safe to use Make repairs before attaching the furnace See Page 4 item 5 Look at Fig 4 The connector pipe and fittings you will need to connect directly to a masonry chimn...

Страница 9: ...al screws at each chimney pipe joint to make the piping rigid Thechimneyconnectormayincludeasec tionforabarometricdraftregulatorbetween the furnace and the chimney Fig 4 5 6 7 The barometric draft reg...

Страница 10: ...ndle Feed Door Latch Ash Door Handle Ash Door Latch Blower and Blower Control Electrical Connections Remove all parts from inside the furnace and inspect for damage including the firebrick as some bre...

Страница 11: ...in the parts bag 3 Unbox the blower and attach to the unit by sliding the flange on the blower between the cabinet back and the unit bottom 4 Now attach the blower to the unit by lining up the two ho...

Страница 12: ...OR ILLUSTRATION PURPOSES ONLY MODEL 1200Q WIRING DIAGRAM FIG 11 LIMIT CONTROL BLACK WHITE WHITE BLACK WHITE BLACK GREEN 2 x 4 JUNCTION BOX BLOWER TO HOUSE SUPPLY NOTE GROUND HOUSE SUPPLY TO INSIDE OF...

Страница 13: ...ed on the label and earlier in this manual are maintained Seal the smoke pipe in the chimney with furnace cement The chimney connector shall be se curely supported and joints fastened with sheet metal...

Страница 14: ...TIONS Operation after loss of power Remove filter if provided Do not expect to keep home at normal temperatures Do not load fuel above bottom of feed door Set Fuel door and Ash door spin draft maximum...

Страница 15: ...15 DRAWINGS FOR ILLUSTRATION PURPOSES ONLY CENTRAL INSTALLATION U S CANADA ADD ON INSTALLATION U S ONLY...

Страница 16: ...AGRAM FIG 14 TO GAS OIL ELECTRIC TRANSFORMER HOTBLAST COMBINATION CONTROL LIMIT FAN JUMPER IN H H POWER SUPPLY GAS OIL ELECTRIC POWER SUPPLY JUNCTION BOX CENTRAL FURNACE BLOWER MOTOR WOOD FURNACE BLOW...

Страница 17: ...AMAGE THE FURNACE OPERATING INSTRUCTIONS The temperature in the plenum of the warm air furnace at which the blower turns on or turns off is controlled by the setting of the pointers in the blower limi...

Страница 18: ...the chimney should be at least 3 feet above the roof and be at least 2 feet higher than any point of the roof within 10 feet Fig 5 See page 28 for list of trouble shooting tips 4 5 6 A DRAFT READING O...

Страница 19: ...19 DRAWINGS FOR ILLUSTRATION PURPOSES ONLY MODEL 1200G PARTS...

Страница 20: ...DOOR GASKET 4 58FT 88066 16 1 2 13 LOCK NUT 2 83444 17 1 2 SAE FLAT WASHER 2 83835 18 3 8 16 LOCK NUT 3 83274 19 ASH DOOR HINGE 1 24960 20 DOOR LATCH 2 24958 21 FEED DOOR PAINTED 1 24962 22 DRAFT CAP...

Страница 21: ...21 DRAWINGS FOR ILLUSTRATION PURPOSES ONLY APPENDIX INSTALLATION A NOTE ANTI BACKDRAFT FLAPPERS OR BAFFLE ARE REQUIRED FOR THIS INSTALLATION...

Страница 22: ...22 DRAWINGS FOR ILLUSTRATION PURPOSES ONLY APPENDIX INSTALLATION B NOTE ANTI BACKDRAFT FLAPPERS OR BAFFLE ARE REQUIRED FOR THIS INSTALLATION...

Страница 23: ...23 DRAWINGS FOR ILLUSTRATION PURPOSES ONLY APPENDIX INSTALLATION C NOTE ANTI BACKDRAFT FLAPPERS OR BAFFLE ARE REQUIRED FOR THIS INSTALLATION...

Страница 24: ...24 DRAWINGS FOR ILLUSTRATION PURPOSES ONLY APPENDIX INSTALLATION D U S ONLY INSTALLATION E U S ONLY...

Страница 25: ...25 DRAWINGS FOR ILLUSTRATION PURPOSES ONLY APPENDIX INSTALLATION F INSTALLATION G...

Страница 26: ...26 DRAWINGS FOR ILLUSTRATION PURPOSES ONLY NOTES...

Страница 27: ...rning green wood not seasoned or dry b Thermostat setting too low for type fuel a Insufficient draft b Smothering fire when adding fresh fuel a Set thermostat higher b Clean chimney c Add raincap to c...

Страница 28: ...EN WRITING ALWAYS GIVE THE FULL MODEL NUMBER WHICH IS ON THE NAMEPLATE ATTACHED TO THE HEATER WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION AS SHOWN IN THIS LIST 1 THE PART NUMBER 2...