IGNITION

After making sure that the stove air intake controls are fully open (completely pull-out towards you), The top-

down method of fire building is recommended for this appliance. After making sure that the stove air intake 

controls are fully open (completely pull-out towards you), Place the largest pieces of wood on the bottom, laid 

in parallel and close together. Smaller pieces are placed in a second layer, crossways to the first. The third layer 

of still smaller pieces are laid crossways to the second, this time with some spaces between. Then the fourth layer 

of loose, small kindling and twisted newspaper sheets tops off the pile. Before igniting the paper and kindling 

wood, it is recommended that you warm up the chimney. This is done to avoid backdraft problems often due to 

negative pressure in the house. If such is the case, open a window slightly near the stove and twist together a few 

sheets of newspaper into a torch. Light up this paper torch and hold it as close as possible to the mouth of the 

pipe inside the combustion chamber to warm up the chimney. Once the updraft movement is initiated, you are 

ready to ignite the stove by lighting the paper and kindling wood inside the combustion chamber.

HEATING

Controlled combustion is the most efficient technique for wood heating because it enables you to select the type 

of combustion you want for each given situation. The wood will burn slowly if the woodstove air intake control is 

adjusted to reduce the oxygen supply in the combustion chamber to a minimum. On the other hand, wood will 

burn quickly if the air control is adjusted to admit a larger quantity of oxygen in the combustion chamber. The air 

intake control on your stove is very simple. If you pull on it out completely towards you, it is fully open. If you push 

on it until it stops the combustion air is reduced to a minimum. Real operating conditions may give very different 

results than those obtained during testing according to the species of wood used, its moisture content, the size 

and density of the pieces, the length of the chimney, altitude and outside temperature.

EFFICIENCY

Efficiencies can be based on either the lower heating value (LHV) or the higher heating value (HHV) of the fuel. 

The lower heating value is when the water leaves the combustion process as a vapor, in the case of woodstoves 

the moisture in the wood being burned leaves the stove as a vapor. The higher heating value is when the water 

leaves  the  combustion  process  completely  condensed.  In  the  case  of  woodstoves,  this  would  assume  the 

exhaust gases are room temperature when leaving the system, and therefore calculations using this heating 

value consider the heat going up the chimney as lost energy. Therefore, efficiency calculated using the lower 

heating value of wood will be higher than the efficiency calculated using the higher heating value. In the United 

States, all woodstove efficiencies should be calculated using the higher heating value. 

The best way to achieve optimum efficiencies is to learn the burning characteristic of this appliance and burn 

well-seasoned wood. Higher burn rates are not always the best heating burn rates; after a good fire is established 

a lower burn rate may be a better option for efficient heating. A lower burn rate slows the flow of usable heat out 

of the home through the chimney, and it also consumes less wood.

VISIBLE SMOKE

The amount of visible smoke being produced can be an effective method of determining how efficiently the 

combustion process is taking place in the given settings. Visible smoke consists of unburned fuel and moisture 

leaving your stove. Learn to adjust the air settings of your specific unit to produce the smallest amount of visible 

smoke. Wood that has not been seasoned properly and has a high wood moisture content will produce excess 

visible smoke and burn poorly.

Primary Air Settings

Slide Damper is located in center of stove under hearth plate. 

Damper Adjustment: Pulling out on damper increases air.

Electric Blower Speed Setting (Variable)

Blower is on High when turned “ON”, Rotate clockwise 

until stop for “LOW”.

Burn Rate

Adjust Damper from fully closed

Burn Time

Blower Speed

Low

closed

@ 30 minutes

Low

Medium - Low

approx. 1” (26 mm)

@ 30 minutes

Low

Medium - High

approx. 1.75” (45 mm)

@ 30 minutes

Low

High

approx. 2.3” (59 mm)

Always On

High

Содержание Forester US2000E

Страница 1: ...veuillez consulter le site www P65warnings ca gov Report Number F19 476 SAFETY NOTICE If this heater is not properly installed a house fire may result For your safety follow the installation instructi...

Страница 2: ...od Colors Metallic Black Flue Pipe Diameter 6 152 5 mm Flue Pipe Type Standard Single Wall or Double Wall Black or Blued Steel 2100 F 650 C Minimum Chimney Height 12 3 7 m Maximum Log Length 21 533 5...

Страница 3: ...surfaces Fix the assembly to the back of the stove with the four screws provided ASH PAN ASSEMBLY Remove ash pan from firebox Under the firebox there are two brackets Slide the ash pan into these brac...

Страница 4: ...me is spent and in the most spacious room possible Recall that wood stoves produce radiating heat the heat we feel when we are close to a wood stove A wood stove also functions by convection that is t...

Страница 5: ...of the unit The clearance between the flue pipe and a wall are valid only for vertical walls and for vertical flue pipe The chimney connector must not pass through an attic or roof space closet or sim...

Страница 6: ...er or not there is combustion present 2 Existing fuel fired equipment in the house such as fireplaces or other heating appliances smell do not operate properly suffer smoke roll out when opened or bac...

Страница 7: ...MUST BE ATTACHED TO THE STRUCTURE OF THE MOBILE HOME SECURING APPLIANCE S ON A PEDESTAL TO THE FLOOR Use the designated holes to secure the unit to the floor SECURING APPLIANCE S WITH LEGS TO THE FLOO...

Страница 8: ...o the room through appliance and chimney connector joints An uncontrollable burn or excessive temperature indicates an excessive draft CHIMNEY Your wood stove may be hooked up with a 6 factory built o...

Страница 9: ...as recommended by the manufacturer The chimney must be the required height above the roof or other obstructions for safety and proper draft operation MASONRY CHIMNEY Ensure that a masonry chimney meet...

Страница 10: ...connector Use this as a pass through for a minimum 24 gauge single wall steel chimney connector Keep solid pak section concentric with and spaced 1 25 4 mm off the chimney connector by way of sheet m...

Страница 11: ...rain or snow also accelerates the drying time A good indicator of if the wood is ready to burn is to check the piece ends If cracks are radiating in all directions from the center then the wood shoul...

Страница 12: ...s the stove s efficiency and leads to accelerated creosote buildup in your chimney TESTING YOUR WOOD When the stove is thoroughly warmed place one piece of split wood about five inches in diameter par...

Страница 13: ...h of the chimney altitude and outside temperature EFFICIENCY Efficiencies can be based on either the lower heating value LHV or the higher heating value HHV of the fuel The lower heating value is when...

Страница 14: ...500 F heat is wasted since a too large quantity is lost into the atmosphere TO PREVENT CREOSOTE BUILD UP Always burn dry wood This allows clean burns and higher chimney temperatures therefore less cre...

Страница 15: ...damaged piece with a new one Perform the procedure backward after replacing it When replacing the glass you should change the glass gasket to make sure you keep it sealed Never wash the glass with a p...

Страница 16: ...on Qty 1 40292A 6 Flue Collar 1 2 88042 Rope Gasket 1 4 1 3 25845 Air Deflector 1 4 891492 Blower Assembly B36 1 5 26060 Rear Shield 1 6 610926 Rear Ashpan US2000E BP 1 7 29068 Pedestal US2000E BP 1 8...

Страница 17: ...11 64 1 5 29039 Brick Retainer left 1 6 29040 Brick Retainer right 1 7 40561 Ash Plug 1 8 24103A Half Pumice Firebrick 4 1 2 X 4 1 2 2 9 891414A Half Firebrick 2 10 89066A Pumice Firebrick 4 1 2 X 9...

Страница 18: ...7 Date _____________________ Engineer Name ________________________________ License No ____________________________________ Company _____________________________________ Telephone No _________________...

Страница 19: ...ECHANGE VEUILLEZ CONSERVER CE GUIDE DANS UN ENDROIT S R DES FINS DE R F RENCE LORSQUE VOUS NOUS CRIVEZ VEUILLEZ INDIQUER LE NUM RO COMPLET DU MOD LE QUI FIGURE SUR LA PLAQUE SIGNAL TIQUE DE L APPAREIL...

Страница 20: ...__________________________ Service de 07 Date _____________________ Nom de l ing nieur ____________________________ N de licence _________________________________ Compagnie ___________________________...

Страница 21: ...1 5 29039 retenue de brique gauche 1 6 29040 retenue de brique droite 1 7 40561 bouchon de cendre 1 8 24103A brique r fractaire demi pierre ponce 4 1 2 x 4 1 2 2 9 891414A demi brique r fractaire 2 1...

Страница 22: ...610922 socle soud US2000E BP 1 10 610925 cendrier US2000E BL 1 11 40566 pied en fonte US2000E BL 4 12 25826 plaque de foyer 1 13 29216 cendrier 1 14 610927 soudure de glissi re d amortisseur 1 15 610...

Страница 23: ...bien tanche Ne lavez jamais la vitre avec un produit qui pourrait la rayer Utilisez un produit sp cialis disponible dans les magasins qui vendent les po les bois La vitre doit tre nettoy e uniquement...

Страница 24: ...z toujours du bois sec Cela permet des combustions propres et des temp ratures de chemin e sup rieures et par cons quent moins de d p t de cr osote Laissez la commande d air compl tement ouverte penda...

Страница 25: ...ales est d apprendre les caract ristiques de br lage de votre appareil et du bois bien s ch Des taux de combustion plus lev s ne sont pas toujours les meilleurs taux de combustion apr s qu un bon feu...

Страница 26: ...pouces de diam tre parall lement la porte sur le lit de braises rouges Maintenez la commande d air compl tement ouverte en tirant dessus et fermez la porte Si l allumage de la pi ce se fait en moins d...

Страница 27: ...t normalement tre consid r comme sec 66 Fendre et empiler le bois avant de l entreposer acc l re son s chage Entreposez le bois sur une surface sur lev e du sol et sous un espace abrit de la pluie ou...

Страница 28: ...LE PO LE DOIT TRE FIX LA STRUCTURE DE LA MAISON MOBILE UTILISEZ LES DEUX 2 TROUS AU FOND DU PI DESTAL DE LA RADIATEUR POUR FIXER L APPAREIL AU SOL Illustration Fixation du r chauffeur au plancher Uti...

Страница 29: ...des mati res combustibles 2 Les appareils foyer existants au sein du domicile tels que des chemin es ou d autres appareils de chauffage mettent des odeurs ne fonctionnent pas correctement mettent des...

Страница 30: ...stible Commencez avec une partie de chemin e Solid Pak fabriqu e en usine agr e d au moins 12 po 304 mm de diam tre int rieur avec une isolation de 1 po 25 4 mm ou plus et un raccord de chemin e de 8...

Страница 31: ...n bon tirage CHEMIN E EN MA ONNERIE Assurez vous qu une chemin e en ma onnerie r ponde aux standards minimum de l Association nationale de protection contre les incendies NFPA en la faisant inspecter...

Страница 32: ...emble avec un ciment r fractaire les carneaux cylindriques sont les plus efficaces Le diam tre int rieur du carneau de chemin e doit tre identique l aspiration des fum es du po le Un carneau trop peti...

Страница 33: ...tirage n est pas recommand e En effet avec un po le bois de combustion contr l e le tirage est r gul d s l admission de l air de combustion dans le po le et non l vacuation D GAGEMENTS AVEC LES MATI R...

Страница 34: ...pr s possible de la chemin e et dans un endroit propice la distribution de chaleur la plus efficace possible dans toute la maison Le po le doit donc tre install dans la pi ce o le plus de temps est p...

Страница 35: ...SUR DES SURFACES CHAUDES ASSEMBL E DE CASSEROLE DE CENDRE Enlevez la casserole de cendre du foyer Sous le foyer il y a deux parenth ses Glissez la casserole de cendre dans ces parenth ses ASSEMBLAGE...

Страница 36: ...OUR D MARRER LE FEU NE LAISSEZ PAS LE PO LE SANS SURVEILLANCE LORSQUE LA PORTE EST L G REMENT OUVERTE NE BR LEZ PAS DE D CHETS NI DE FLUIDES INFLAMMABLES TELS QUE L ESSENCE LE NAPTHA OU L HUILE POUR M...

Страница 37: ...U PO LE EFFICACE ET FIABLE ET VOUS PERMETTRA DE COMMANDER CORRECTEMENT TOUTE PI CE D TACH E GARDEZ LE DANS UN LIEU S R POUR TOUTE CONSULTATION ULT RIEURE MOD LES US2000E U S Environmental Protection A...

Отзывы: