background image

-5-

• 

Do  not  place  any  combustible  material  within  4’ 

(1.2 m) of the front of the unit.

• 

The  clearance  between  the  flue  pipe  and  a  wall 

are valid only for vertical walls and for vertical flue 

pipe.

•  The chimney connector must not pass through an 

attic  or  roof  space,  closet  or  similar  concealed 

space, a floor, or a ceiling.

• 

For Canadian installations, where passage through 

a  wall,  or  partition  of  combustible  construction 

is  desired,  the  installation  must  conform  to  CAN/

CSA-B365.

• 

A flue pipe crossing a combustible wall must have a 

minimum clearance of 18” (457.2 mm).

• 

To  reduce  flue  clearances  from  combustible 

materials, contact your local safety department.

SPECIAL MOBILE HOME REQUIREMENTS (USA ONLY)

WARNING! - Do not install in a sleeping room.

CAUTION! - The structural integrity of the mobile home floor, wall, and ceiling/roof must be maintained.

In addition to the previously detailed installation requirements, mobile home installations must meet the following 

requirements:

• 

The space heater is to be connected to a factory-built chimney conforming to CAN/ULC-S629, Standard for 

650°C Factory-Built Chimneys.

• 

The heater must be permanently attached to the floor (see “Securing Appliance’s On A Pedestal To The Floor” 

section of this manual.

•  The heater must be electrically grounded to the steel chassis of the mobile home with 8 GA copper wire using 

a serrated or star washer to penetrate paint or protective coating to ensure grounding.

• 

When  moving  your  mobile  home,  all  exterior  venting  must  be  removed  while  the  mobile  home  is  being 

relocated. After relocation, all venting must be reinstalled and securely fastened.

•  Outside air is mandatory for mobile home installation. See your dealer for purchasing.

• 

Check with your local building officials as other codes may apply.

• 

Only use the specified components listed in this manual for this unit. The use of components that are not meant 

for this unit can cause unsafe conditions.

COMBUSTION AIR ASSEMBLY INSTRUCTIONS (MOBILE HOME INSTALLATIONS - REQUIRED)

This appliance requires a source of combustion air. If your home is of tight construction or has negative pressure 

problems, you will need an outside source of air. Below is a list of possible indicators that a source of outside 

combustion air may be required.

Key

Dimensions

Inch

mm

D

Backwall to Stove

17

432

E

Sidewall to Stove

26

661

F

Wall to corner (Angled Installation)

18

458

G

Ceiling Height

84

2134

H

Backwall to Flue

19

483

J

Sidewall to Flue

35

889

H

D

J

E

CLEARANCE TO WALLS 

Side 

w

all

Backwall

F

F

Side 

w

all

Backwall

CORNER INSTALLATION 

CLEARANCE TO WALLS

Ceiling

CORNER INSTALLATION 

CLEARANCE TO 

WALLS & CELING

G

D

H

CLEARANCES TO COMBUSTIBLES

It is of utmost importance that the clearances to combustible materials be strictly adhered to during installation 

of the stove. Refer to the provided tables:

All manuals and user guides at all-guides.com

Содержание ASHLEY AW3200E

Страница 1: ...t de la Californie comme causant le cancer et des malformations cong nitales ou autres dommages au f tus Pour obtenir plus de renseignements veuillez consulter le site www P65warnings ca gov This manu...

Страница 2: ...y claims Combustible Wood Colors Metallic Black Flue Pipe Diameter 6 153 mm Flue Pipe Type Standard Single Wall or Double Wall Black or Blued Steel 2100 F 650 C Minimum Chimney Height 12 3 7 m Maximum...

Страница 3: ...s A to the center section B of skirting and secure with four 4 truss head screws 2 Attach the side skirting sections C D to the corner pieces and secure with four 4 truss head screws 3 Slide the U sha...

Страница 4: ...SUCH LIQUIDS WELL AWAY FROM THE HEATER WHILE IT IS IN USE IN THE EVENT OF A CHIMNEY FIRE PUSH THE AIR CONTROL FULL CLOSED TO DEPRIVE THE FIRE OF OXYGEN CALL THE FIRE DEPARTMENT DO NOT CONNECT TO ANY...

Страница 5: ...r wire using a serrated or star washer to penetrate paint or protective coating to ensure grounding When moving your mobile home all exterior venting must be removed while the mobile home is being rel...

Страница 6: ...ertified wood stove installer Drill a 5 hole through the wall at the desired point of entry The point of entry should be at or below the level of the intake air tube on the wood stove Slide the tail p...

Страница 7: ...appliance and chimney connector joints An uncontrollable burn or excessive temperature indicates an excessive draft CHIMNEY Your wood stove may be hooked up with a 6 factory built or masonry chimney...

Страница 8: ...anufacturer The chimney must be the required height above the roof or other obstructions for safety and proper draft operation MASONRY CHIMNEY Ensure that a masonry chimney meets the minimum standards...

Страница 9: ...of 1 25 4 mm each construct a wall pass through There shall be a minimum 6 152 4 mm separation area containing fiberglass insulation from the outer surface of the wall thimble to wall combustibles Sup...

Страница 10: ...ions it may rot instead of drying This point cannot be over stressed the vast majority of the problems related to the operation of a wood stove is caused by the fact that the wood used was too damp or...

Страница 11: ...wood only Higher efficiencies and lower emissions generally result when burning air dried seasoned hardwoods as compared to softwoods or to green or freshly cut hardwoods Attempts to use wet or unsea...

Страница 12: ...rates after a good fire is established a lower burn rate may be a better option for efficient heating A lower burn rate slows the flow of usable heat out of the home through the chimney and it also co...

Страница 13: ...g your fuel the primary air slide should be set at the medium setting which is about 1 2 inch open from the fully closed position For a low burn setting once the high burn or medium fuel load is burne...

Страница 14: ...Make sure the blades do not have build up CAUTION Do not overfire appliance You are overfiring if any part of the appliance glows red Close the door and shut damper immediately to reduce the air suppl...

Страница 15: ...tended periods While the modern combustion systems in heaters drastically reduce the amount of CO emitted out the chimney exposure to the gases in closed or confined areas can be dangerous Make sure y...

Страница 16: ...INSULA TION AND TEMPERATURE RATING 105 C CAUTION MOVING PARTS CAN CAUSE INJURY DO NOT OPERATEWITH COVER REMOVED DANGER SHOCKHAZARD DISCONNECT POWERSOURCEBEFOREINSTALLATION AND WHENEVER SERVICING BLOWE...

Страница 17: ...912 Ash Drawer 1 8 26548 Ash Drawer Support 1 9 26541 Left Side Skirt 1 10 40597 Skirt Corner 2 11 26546 Front Skirt 1 12 26553 Right Side Skirt 1 13 69911 Pedestal 1 IN ORDER TO MAINTAIN WARRANTY COM...

Страница 18: ...lf Brick Ash Plug 1 7 86698 Tube 1 Secondary Air Tube 4mm 1 8 86699 Tube 2 3 Secondary Air Tube 3mm 2 9 86700 Tube 4 Secondary Air Tube 2 5mm 1 10 86701 Tube 5 Secondary Air Tube 2 0mm 1 11 86702 Tube...

Страница 19: ...19 Notes All manuals and user guides at all guides com...

Страница 20: ..._______ Engineer Name ________________________________ License No ____________________________________ Company _____________________________________ Telephone No _________________________________ Stov...

Страница 21: ...ujours le num ro de mod le complet qui se trouve sur la plaque signal tique fix e sur l appareil de chauffage Lors de commandes de pi ces d tach es donnez toujours les informations suivantes telles qu...

Страница 22: ..._____ Service de 07 Date _____________________ Nom de l ing nieur ____________________________ N de licence _________________________________ Compagnie ___________________________________ N de t l pho...

Страница 23: ...cendre demi brique 1 7 86698 tube d air secondaire 1 4mm 1 8 86699 tube d air secondaire 2 3 3mm 2 9 86700 tube d air secondaire 4 2 5mm 1 10 86701 tube d air secondaire 5 2 0mm 1 11 86702 tube d air...

Страница 24: ...niture de foyer 1 7 69912 Tiroir cendres 1 8 26548 Support de tiroir cendres 1 9 26541 Jupe c t gauche 1 10 40597 Coin de jupe 2 11 26546 Jupe avant 1 12 26553 Jupe c t droit 1 13 69911 Pi destal 1 AF...

Страница 25: ...ct avec une surface chaude Garder le fil lectrique 12po 30cm au moins de la surface du po le ou des conduits ATTENTION PI ces mobiles pouvant causer des blessures Ne pas faire fonctionner si le cou ve...

Страница 26: ...alis disponible dans les magasins o les po les bois sont vendus Le verre ne doit tre lav qu froid ATTENTION LES CENDRES POURRAIENT CONTENIR DES EMBRES CHAUDES M ME APR S DEUX JOURS SANS FAIRE FONCTION...

Страница 27: ...uent des r sidus de cr osote s accumulent sur le rev tement du conduit de fum e Lorsqu elle est allum e cette cr osote fait un feu extr mement lev Le raccord de chemin e et la chemin e doivent tre ins...

Страница 28: ...t optimal de cet appareil il est recommand de le faire fonctionner avec une charge de bois approximativement quivalente la hauteur des briques r fractaires Il est important de noter que la combustion...

Страница 29: ...on suffi sante pour liminer la fum e ou les odeurs caus es par ces feux ATTENTION ne laissez pas l appareil sans surveillance avec la porte ouverte Remarque utilisez uniquement du bois de chauffage s...

Страница 30: ...ire ou de b ches avec des additifs chimiques Les b ches fabriqu es partir de sciure de bois compress e 100 peuvent tre br l es mais faites attention br ler trop de ces b ches en m me temps Commencez a...

Страница 31: ...ne saurait trop soulign que la vaste majorit des probl mes li s au fonctionnement d un insert bois est caus e par le fait que le bois utilis tait trop humide ou avait s ch dans de mauvaises conditions...

Страница 32: ...une partie de chemin e Solid Pak fabriqu e en usine agr e d au moins 12 po 304 mm de diam tre int rieur avec une isolation de 1 po 25 4 mm ou plus et un raccord de chemin e de 8 po de diam tre int ri...

Страница 33: ...u homologu Mur combustible Consulter D gagement des combustibles Protecteur de plancher Conduit de raccordement de chemin e Solive de toit combustible Chemin e homologu Mitre Solin CHEMIN E EN MA ONNE...

Страница 34: ...ique un tirage excessif Pente de po par pied Partie m le vers le bas 3 vis Vers l appareil Installer l extr mit sertie vers le po le Direction de la circulation des gaz de conduits de fum e CHEMIN E T...

Страница 35: ...teur de po le bois certifi Percez un trou de 5 pouces travers le mur au point d entr e souhait Le point d entr e doit tre au niveau ou en dessous du niveau du tuyau d air d admission sur le po le bois...

Страница 36: ...dre aux exigences suivantes Le chauffe eau doit tre connect une chemin e pr fabriqu e conforme la norme CAN ULC S629 norme pour les chemin es pr fabriqu es 650 C Le radiateur doit tre fix en permanenc...

Страница 37: ...cons quent tre install dans la pi ce o vous passez le plus de temps et dans la pi ce la plus spacieuse possible Rappelez vous que les po les bois produisent une chaleur rayonnante la chaleur que nous...

Страница 38: ...ux pi ces d angle A la section centrale B de la plinthe et fixez les avec quatre 4 vis t te bomb e 2 Fixez les plinthes lat rales C et D aux pi ces d angle et fixez les avec quatre 4 vis t te bomb e 3...

Страница 39: ...DE D CHETS NI DE FLUIDES INFLAMMABLES TELS QUE L ESSENCE LE NAPTHA OU L HUILE POUR MOTEUR NE CONNECTEZ PAS LE PO LE UN CONDUIT OU CIRCUIT DE DISTRIBUTION D AIR FERMEZ TOUJOURS LA PORTE APR S L ALLUMAG...

Страница 40: ...Californie comme causant le cancer et des malformations cong nitales ou autres dommages au f tus Pour obtenir plus de renseignements veuillez consulter le site www P65warnings ca gov Conservez ces ins...