background image

IMPORTANT SAFETY INFORMATION 

CONTINUED

13. Keep appliance area clear and free from combustible materials, gasoline and other flammable

vapors and liquids.

15. Any safety screen or guard removed for servicing, must be replaced prior to heater operation.

16. This vent-free gas heater is intended to be smokeless.  If logs appear to smoke, turn off the

heater and call a qualified service person.  Initial burn off may cause slight smoke and odor
during the first four hours of operation.

17. Input ratings are shown in BTU per hour and are for elevations up to 2,000 feet. For elevations

above 2,000 feet, input ratings should be reduced 4 percent per 1,000 feet above sea level.
Refer to the National Fuel Gas Code.

18. The appliance and its appliance main gas shut off valve must be disconnected from the gas

supply piping system during any pressure testing of that system at test pressures in excess of 1/
2 psig (3.5 kPa).

19. The appliance must be isolated from the gas supply piping system by closing its equipment

shut off valve during any pressure testing of the gas supply piping system at test pressures
equal to or less than 1/2 psig (3.5 kPa).

20. Do not use this heater if any part has been under water.  Immediately call a qualified service

technician to inspect the room heater and to replace any part of the control system and any
gas control that has been under water.

4

Features:

Features:

Features:

Features:

Features:

• Heating Efficiency - 99.9%
• Wide BTU Range: 27,000-39,900.
• Safe Operation -

Oxygen Depletion Sensor (ODS).

• Fibre Ceramic Logs.
• 120 CFM Blower
• Push-Button Piezo Ignitor.
• Clean Operation.
• Easy Operation.
• Heats up to 1,200 square feet.
• Optional Remote Control, Wall Switch

and Wall Thermostat Kits

PRODUCT FEATURES

9947 Vent-free Gas Pedestal Heater

9947 Vent-free Gas Pedestal Heater

9947 Vent-free Gas Pedestal Heater

9947 Vent-free Gas Pedestal Heater

9947 Vent-free Gas Pedestal Heater

Figure 1.

Figure 1.

Figure 1.

Figure 1.

Figure 1.

Содержание 9947

Страница 1: ...om a Immediately call your gas supplier from a Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s neighbor s phone Follow the gas supplier s neighbor s phone Follow t...

Страница 2: ...S LIST FOR HEATER ASSEMBLY 16 17 PARTS LIST FOR BURNER AND LOG ASSEMBLY 18 19 TROUBLE SHOOTING 20 21 OPTIONAL EQUIPMENT 22 WIRING DIAGRAMS 23 25 NOTES 26 LIMITED WARRANTY POLICY 27 TABLE OF CONTENTS 2...

Страница 3: ...efer to this owner s manual Installation and service must be performed by a qualified installer service agency or the gas supplier 5 To prevent malfunction and or sooting a vent free gas heater should...

Страница 4: ...test pressures in excess of 1 2 psig 3 5 kPa 19 The appliance must be isolated from the gas supply piping system by closing its equipment shut off valve during any pressure testing of the gas supply p...

Страница 5: ...nd 9947N Unvented Gas Heater vented Gas Heater vented Gas Heater vented Gas Heater vented Gas Heaters s s s s 1 Packet containing Homeowner s Installation instructions 2 Three 3 individually wrapped f...

Страница 6: ...ont of the heater ont of the heater ont of the heater ont of the heater In high traffic areas In high traffic areas In high traffic areas In high traffic areas In high traffic areas In windy or draft...

Страница 7: ...c right c right clearances are determined when facing the fr learances are determined when facing the fr learances are determined when facing the fr learances are determined when facing the fr learan...

Страница 8: ...ntel to an acceptable height OR Remove the mantel MANTEL CLEARANCES BACK WALL MANTEL SHELF DISTANCE TO UNDERSIDE OF MANTEL UNDERSIDE OF MANTEL SHELF TOP OF HEATER MINIMUM CLEARANCE TO BACK WALL FLOOR...

Страница 9: ...ll gas volume to heater Excessive pressure loss will occur if the diameter to allow full gas volume to heater Excessive pressure loss will occur if the diameter to allow full gas volume to heater Exce...

Страница 10: ...e 5 contact your dealer and replace the regulator FIGURE 7 Pressure Test Point Location 10 GAS CONNECTION GAS PRESSURE CHECK FIGURE 6 Rear View of 9947 Vent Free Gas Heater FIGURE 6 Rear View of 9947...

Страница 11: ...suc embellishments such as pine cones h as pine cones h as pine cones h as pine cones h as pine cones vermiculite or r vermiculite or r vermiculite or r vermiculite or r vermiculite or roc oc oc oc o...

Страница 12: ...4 When lighting the pilot follow these instructions exactly BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will...

Страница 13: ...y lit after several tries turn control knob to OFF and call your gas supplier 9 Turn valve knob clockwise to ON 10 Wait about one minute then turn burner switch D to ON It will take a few minutes for...

Страница 14: ...fore readjusting the heater when the contr ore readjusting the heater when the contr ore readjusting the heater when the contr ore readjusting the heater when the contr ore readjusting the heater when...

Страница 15: ...any part of heater Logs Brush with soft bristle brush or vacuum with brush attachment Vacuum loose particles and dust from the front and rear burner control and piezo Inspect burner s and air intake...

Страница 16: ...HEATER ASSEMBLY 16...

Страница 17: ...r Frame 1 20 89933 Long Louver 2 21 89934 Short Louver 4 22 24795 Front Screen 1 23 24794 Side Screen 2 24 86483 Thermodisc Bracket 1 25 80381 Thermodisc 1 N S 83351 8 x 3 8 Hex Head Screw 2 26 89824...

Страница 18: ...BURNER AND LOG ASSEMBLY 14 4 2 18 20 19 11 8 9 18 3 5 6 13 16 15 1 12 7 17 10...

Страница 19: ...8 CONTROL BRACKET 1 8 81198 CONTROL VALVE NATURAL 1 81202 CONTROL VALVE L P 1 9 83464 10 32 x 3 8 MACHINE SCREW 4 10 89918 GAS LINE NATURAL 1 89923 GAS LINE L P 1 11 C42373 ROCKER SWITCH 1 12 80376 WI...

Страница 20: ...Pilot position Air in gas lines when installed ODS Pilot is clogged Gas regulator setting is not correct Turn on gas supply or open manual shutoff valve Turn control knob while in PILOT position Pres...

Страница 21: ...roblem will stop after a few hours of operation Run the heater with the damper open if you have one or open a window for the first few hours Log heater is intended to be smokeless Turn OFF heater and...

Страница 22: ...ENT REMOTE SKYTECH SKYTECH 1001 ON OFF INDICATOR R E M O T E NO OFF SKYTECH 50 60 70 80 90 21 10 32 c 50 60 70 80 90 21 10 32 c MODEL RCK60 REMOTECONTROLKIT MODEL WSK60 WALLSWITCHKIT MODEL WTK60 WALLT...

Страница 23: ...INS 1 4 FEMALE INS 1 4 FEMALE INS 1 4 MALE INS 1 4 MALE INS 1 4 FEMALE INS BLACK BLACK WHITE WHITE WHITE WHITE WHITE NEUTRAL BLACK BLACK BLACK BLACK BLACK HOT GREEN GREEN GREEN GREEN GREEN GROUND RHE...

Страница 24: ...Not all Optional Kits will work together Example The RCK60 Remote Control Kit the WSK60 Wall Switch Kit and the WTK60 Wall Thermostat Kit cannot be used at the time 2 When using any of the three Optio...

Страница 25: ...of them can be used at a time Example If you want to control the operation of this unit with the Remote Control then you must turn the Wall Switch OFF When trying to use two Optional kits at once one...

Страница 26: ...NOTES NOTES NOTES NOTES NOTES 26...

Страница 27: ...IEU OF OTHER WARRAN THIS WARRANTY IS EXPRESSLY IN LIEU OF OTHER WARRAN THIS WARRANTY IS EXPRESSLY IN LIEU OF OTHER WARRAN THIS WARRANTY IS EXPRESSLY IN LIEU OF OTHER WARRAN THIS WARRANTY IS EXPRESSLY...

Страница 28: ...TALLING YOUR HEATER FILL IN THE SERIAL NUMBER IN THE SPACE PROVIDED ABOVE FOR YOUR RECORDS 1 The PART NUMBER PART NUMBER PART NUMBER PART NUMBER PART NUMBER 2 The PART DESCRIPTION PART DESCRIPTION PAR...

Отзывы: