INSTRUCTION MANUAL 

PELLET HEATING STOVES 

AND PELLET STOVES 

 
 

HYDRO KANTINA 20/24 KW 
HYDRO CURVED FRONT  20/24 KW 
HYDRO STRAIGHT FRONT 20/24 KW 
HYDRO 13/17.5 KW 
EV 14 
EV 20 
EV 24 
EV 34 
EV 50 

 
 

 

 

EN 

Summary of Contents for EV 14

Page 1: ...INSTRUCTION MANUAL PELLET HEATING STOVES AND PELLET STOVES HYDRO KANTINA 20 24 KW HYDRO CURVED FRONT 20 24 KW HYDRO STRAIGHT FRONT 20 24 KW HYDRO 13 17 5 KW EV 14 EV 20 EV 24 EV 34 EV 50 EN ...

Page 2: ... anomaly concerning the flame be detected or however in any other case NEVER SWITCH OFF the stove by disconnecting it from the mains Use the relevant button Disconnecting the stove from the mains will prevent exhaust fumes from being extracted 7 Should ignition phase take longer than expected due to damp or poor quality pellets generating excessive smoke in the combustion chamber open the door to ...

Page 3: ...ON p 21 07 01 ELECTRICAL CONNECTION p 21 07 02 EXTERNAL THERMOSTAT p 21 08 ELECTRONICS WITH HYDRO STOVE 6 KEY LCD DISPLAY p 21 08 01 CONSOLE p 21 08 02 THE MENU p 22 08 03 USER FUNCTIONS p 23 09 HYDRO STOVE ALARMS p 24 10 HYDRO STOVE CONNECTIONS p 25 11 CLEANING and ROUTINE MAINTENANCE p 26 11 01 HYDRO STOVES p 26 12 EV STOVE INSTALLATION p 26 12 01 HYDRAULIC CONNECTION p 26 12 02 DOMESTIC WATER K...

Page 4: ... place any object on the cable and do not bend it Avoid using extension cables as their temperature may increase excessively posing fire hazards Never use one single extension cable to power several appliances During normal functioning some parts of the stove may become extremely hot such as the door the glass or the handle Be careful especially with children Do not touch any hot parts if not wear...

Page 5: ...at ideal working conditions since the Auger tube is very long CAUTION If the installation is not carried out according to the procedures indicated in the event of a power failure part of the combustion fumes could be spilled into the environment In some cases it may be necessary to install an uninterruptible power supply CAUTION Being a heating appliance some parts of the stove can become extremel...

Page 6: ...he 20 24 kW powers domestic water can also be heated using a dedicated kit called ACS HYDRO 20 24 KW TECHNICAL DRAWING 03 2 KANTINA 20 24 KW HYDRO STOVE Thanks to the technology with which it was designed this pellet fuelled stove can be installed resting it directly against the wall without leaving any gaps Hydro Kantina is available in the 20 kW or 24 kW version providing ample power to ensure o...

Page 7: ...77 179 77 145 77 164 77 Flue gas temperature at flue spigot or socket Temperatura uscita fumi C 175 100 200 100 165 100 185 100 Flue gas mass flow Flusso massico dei fumi g s 10 8 4 8 14 3 4 8 10 9 4 8 13 2 4 8 Efficiency Rendimento 91 5 94 5 90 0 94 5 92 0 94 5 91 0 94 5 Total heat output Potenza termica Kw 18 5 5 0 23 0 5 0 18 5 5 0 22 5 5 0 Water heat output Potenza termica resa all acqua Kw 16...

Page 8: ... heating stove which with its refined line and its compact dimensions becomes a discreet piece of furniture The small fan on board allows very rapid heating of the environment in which it is installed TECHNICAL DRAWING 03 5 HYDRO 17 5 KW TECHNICAL DRAWING ...

Page 9: ... 13 3 2 9 Space heat output Potenza termica resa all ambiente Kw 2 2 1 0 3 0 1 2 CO emission at 13 of O2 Emissioni di CO al 13 di O2 0 0033 0 016 0 0078 0 0065 Maximum water operating pressure Massima pressione di esercizio dell acqua bar 3 3 3 3 Discharge control operating temperature Temperatura di intervento termostato sicurezza acqua C Electrical power supply Potenza elettrica assorbita W 380 ...

Page 10: ...act rear or high fume exhaust self cleaning burn pot convenient separate opening of the ash drawer at the bottom unburned pellets conveyor system to optimise combustion and to reduce emissions a recirculation pump expansion vessel and safety valve It has been designed to make extraordinary maintenance very simple EV14 EV20 EV24 TECHNICAL DRAWING ONLY EV14 ...

Page 11: ...2 5 0 5 2 5 0 5 2 5 0 5 2 5 0 5 Maximum water pressure safety valve Massima pressione dell acqua valvola di sicurezza Bar 3 0 3 0 3 0 3 0 3 0 Stove Class EN 303 5 2012 Classe della caldaia EN 303 5 2012 5 5 5 5 5 Electrical power supply Potenza elettrica assorbita W 380 400 400 390 390 Electrical power supply of circulator Potenza elettrica assorbita della pompa W 45 45 45 45 45 Electrical power c...

Page 12: ...7 5 KW 1 Electronic pump 2 Pressure transducer 3 3 bar safety valve 4 Heating delivery 5 Heating return 6 Expansion vessel 7 Fume motor 8 Automatic breather valve 9 Auger motor 10 Air fan some models only 03 11 COMPONENT DESCRIPTION EV STOVES 1 Electronic pump 2 Pressure transducer 3 3 bar safety valve 4 Heating delivery 5 Heating return 6 Expansion vessel 7 Fume motor 8 Depressor 9 Manual reset t...

Page 13: ...bly of the flue pipe must be carried out in a workmanlike manner and according to European UNI 10683 and national regulations local regulations and the technical specifications and warnings contained in this Instruction Manual d The smoke outlet must be connected to the flue pipe by means of telescopic fittings e The diameter of the flue must be less than 150 mm f The connection to the flue pipe m...

Page 14: ...ther stainless steel or aluminised The stove is fitted with a Φ 80mm rear round fume outlet and a joint connection to be connected to the vent pipe In order to facilitate connection to the rigid steel flue it is advisable to use telescopic fittings which in addition to facilitating the procedure also compensate for the thermal expansion of both the firebox and the flue itself Seal the vent pipe jo...

Page 15: ... due to an excess amount of oxygen wears down the combustion chamber sooner than expected Instead poor draught slows down combustion resulting in a decrease in the stove temperature fume spillage inside the room a loss of stove efficiency and a dangerous build up in the flue pipe To avoid excessive draught it is advisable to use a draught regulator see figure to the side 5 3 EFFICIENCY OF THE HYDR...

Page 16: ...es storage rooms combustibles stores etc These air vents must be made in such a way that they cannot be blocked either internally or externally and should be protected by a grille metal net or other suitable protection without reducing the minimum dimensions If the stoves are to be installed in rooms where it is surrounded by combustible materials e g furniture wood cladding etc the following mini...

Page 17: ...LLATION EXAMPLES HYDRO EV STOVE EXAMPLES OF INCORRECT INSTALLATION Exhaust pipes must never be fitted pointing downwards or horizontally so that fumes are discharged directly through the external wall coupling ...

Page 18: ...17 06 1 HYDRO STOVES CONNECTION SYSTEM DIAGRAMS ...

Page 19: ...18 ...

Page 20: ...19 06 2 EV STOVE SYSTEM CONNECTION DIAGRAMS ...

Page 21: ...technician This function offers the choice of 2 types of system 1 The stove works based on the stove temperature room temperature or thermostat 2 The stove works on the basis of a probe for the PUFFER A probe that controls the temperature of the external PUFFER can be installed in the AMB position wiring diagram ...

Page 22: ...t be allowed to circulate inside its housing to prevent overheating this is possible by respecting the minimum distances and making ventilation holes The use of hosing is recommended that connects the appliance to the hydraulic system as in the case of ordinary or extraordinary maintenance this makes it easy to move It is also recommended to install a dirt separator as the electronic pump could ca...

Page 23: ...ontrol board is equipped with a lithium battery guaranteeing the internal time clock a 3 5 year long life Menu 02 SET CHRONO Submenu 02 01 ENABLE CHRONO Allows every chrono thermostat function to be enabled or disabled Submenu 02 02 DAILY PROGRAM The daily programmable chrono thermostat functions can be enabled disabled and set Submenu 02 03 WEEKLY PROGRAM The weekly programmable chrono thermostat...

Page 24: ...ve is on Start up phase The stove performs all the steps of the start up phase according to the parameters concerning its levels and times The display will show the wording ON as there is no pellet loading but the exhaust blower is in operation PELLET LOADING state will occur where the pellets are being loaded into the burn pot Once the pellets have started to burn and the fume temperature is incr...

Page 25: ...the stove switches off 09 HYDRO STOVE ALARMS In the event of a malfunction the control board indicates the problem and activates various procedures depending on the type of alarm The possible alarm messages are listed below Cause Display shows Fume temperature sensor FUME PROBE ALARM Fume overheating ALARM HOT TEMP Ignition fault ALARM NO FIRE Switches off when in working mode ALARM NO FIRE Power ...

Page 26: ...ugh terminal AL 1 in CN4 allows the controller to acquire this change of state ALARM SIC FAIL is displayed and the system is stopped Unscrew the black cap on the back of the stove and press the button to reset the contact Faulty fume fan alarm In the event that the fume fan fails the stove stops and the ALARM FAN FAIL message is displayed The shutdown procedure is immediately activated 10 HYDRO ST...

Page 27: ...stion air intake that reaches an external wall or a wall of an adjacent room with an external air intake Ø 80mm minimum diameter The adjacent room must not be a bedroom or bathroom or contain any fire risks such as storerooms garages combustible materials stores etc These air intakes must be made in such a way as to avoid being blocked internally or externally and should be covered with a grille m...

Page 28: ... the power supply to the auger tube and would send the stove into DEP alarm Press and hold the P5 button to display the system pressure Having checked the latter vented the system loaded the pellets and performed INITIAL LOAD switch on the stove The stove contains the cleaning mechanism of the burn pot and of the turbulators Before loading the pellets the stove activates these cleaning devices so ...

Page 29: ...ess settings and control board programming The menu items providing access to the technical setting are protected by access code USER MENU The table below briefly describes the menu structure focusing in particular on the functions available to users Menu 01 SET CLOCK Use this function to set current time and date The control board is equipped with a lithium battery guaranteeing the internal time ...

Page 30: ...tton P4 Initial loading is only enabled if the stove is turned off Menu 07 STOVE STATUS This function displays the current status of the stove showing the status of all the devices connected to it A few examples are included in the following pages The following will be displayed status time including ignition shutdown work etc the pellet load and power the flue gas temperature and the motor rpm th...

Page 31: ... on only at the end of the safety period of time set and if the fume temperature has not cooled Domestic hot water kit If the product was purchased with a domestic Kit after connecting the water inlet and outlet turn on the stove When the stove is working and a sanitary hot water valve is opened the display will show DOMESTIC WATER The stove if it is in the modulation state will move to maximum po...

Page 32: ...status can be reset by pressing the P4 button Safety thermostat If the safety thermostat detects a water temperature exceeding the trigger threshold it immediately switches off the auger tube to which it is connected in series while acquiring this change in status via the AL1 terminal on CN4 The message THERMAL SAFETY ALARM appears on the display and the system is switched off Unscrew the black ca...

Page 33: ...32 15 EV STOVE CONNECTIONS ...

Page 34: ...ER 7 FUME MOTOR ENCODER 8 STOVE PROBE 9 ROOM PROBE 10 EXTERNAL THERMOSTAT 11 FUME PROBE 12 AUGER MOTOR 13 TURBULATORS MOTOR 14 PUMP CIRCULATOR 15 DOOR DEPRESSORS CONTACT 16 SAFETY THERMOSTAT 17 SPARK PLUG 18 FUME FAN 19 FIREBOX CLEANER MOTOR AUGER CONNECTION DEPRESSORS SAFETY THERMOSTAT DOOR CONTACT FIREBOX CLEANER NOTES 1 CLEANER MOTOR 2 STOVE SAFETY THERMOSTAT 3 20 PA DEPRESSOR 4 40 PA DEPRESSOR...

Page 35: ...ean the stove Do not use abrasive material or products that could corrode or bleach surfaces At the end of the season with the last ignition the pellet remaining in the auger must be consumed completely The auger must remain empty to avoid clogging due to solidified sawdust residue created by moisture 17 HYDRO EV EXTRAORDINARY MAINTENANCE The Buyer must have the flue and flue pipe cleaned annually...

Page 36: ...CALL TECHNICAL SUPPORT FAULTY FUME SENSOR CALL TECHNICAL SUPPORT FAULTY EXHAUST BLOWER CALL TECHNICAL SUPPORT FAULTY CONTROL BOARD CALL TECHNICAL SUPPORT POWER OUTAGE CHECK PLUG AND POWER SUPPLY NO PELLETS CHECK HOPPER AUGER TUBE BLOCKED BY FOREIGN BODY DISCONNECT PLUG EMPTY HOPPER REMOVE ANY FOREIGN BODY SUCH AS NAILS ETC POOR QUALITY PELLETS CHANGE PELLET TYPE INSUFFICIENT PELLET SET VALUE AT MI...

Page 37: ...RT FUME SENSOR ALARM FAULTY FUME SENSOR CALL TECHNICAL SUPPORT FUME SENSOR DISCONNECTED CALL TECHNICAL SUPPORT ALARM HOT TEMP FAULTY FUME SENSOR CALL TECHNICAL SUPPORT FAULTY CONTROL BOARD CALL TECHNICAL SUPPORT FAULTY EXCHANGER BLOWER CALL TECHNICAL SUPPORT EXCESSIVE PELLET SET VALUE AT MAXIMUM HEAT OUTPUT CALL TECHNICAL SUPPORT RADIOCEMOTE CONTROL NOT CONNECTING FIELD SEARCH POSSIBLE INTERFERENC...

Page 38: ...THERMOSTAT LOCATED ON STOVE BACK AUGER TUBE BLOCKED BY FOREIGN BODY DISCONNECT PLUG EMPTY HOPPER REMOVE ANY FOREIGN BODY SUCH AS NAILS ETC FAULTY AUGER TUBE MOTOR CALL TECHNICAL SUPPORT ACTIVE ALARM SEE ALARM SECTION DIRTY BURN POT CLEAN BURN POT TEMPERATURE TOO COLD REPEAT SWITCHING ON PHASE SEVERAL TIMES EMPTYING THE BURN POT UPON EACH TIME DAMP PELLETS CHECK PELLET STORAGE LOCATION FAULTY GLOW ...

Page 39: ...ORARY POWER OUTAGE LET STOVE COOL DOWN MANUALLY RESET THERMOSTAT ON BACK SWITCH STOVE ON AGAIN FAULTY EXCHANGER BLOWER CALL TECHNICAL SUPPORT FAULTY THERMOSTAT WITH RESET CALL TECHNICAL SUPPORT FAULTY CONTROL BOARD CALL TECHNICAL SUPPORT FUME SENSOR ALARM FAULTY FUME SENSOR CALL TECHNICAL SUPPORT FUME SENSOR DISCONNECTED CALL TECHNICAL SUPPORT HOT FUME ALARM FAULTY FUME SENSOR CALL TECHNICAL SUPPO...

Page 40: ...maintenance ____________ ____________ Technical Assistance Centre stamp Date 2nd maintenance ____________ ____________ Technical Assistance Centre stamp Date 3rd maintenance ____________ ____________ Technical Assistance Centre stamp 10 CERTIFIES ...

Page 41: ...rrectly use operate and perform maintenance on the appliance CUSTOMER Signature DEALER INSTALLER Signature Copy of the dealer or installer CERTIFICATE OF INSTALLATION AND TESTING CUSTOMER _______________________________________ STREET ROAD ____________________________________________ CITY _________________________________________ POSTAL CODE ___________________________________________ PROVINCE ___...

Page 42: ...nterpretation can be equated with the cases listed must also be considered included among the cases of exclusion of the guarantee All the following differences related to the natural characteristics of the coating materials are excluded from the warranty the grains of the stones that are the main characteristic and that guarantee their uniqueness any small cracks or cracks that could be highlighte...

Page 43: ...n totale ou partielle sans autorisation expresse de Eva Stampaggi S r l est interdite Die angegebenen Daten und Eigenschaften binden das Unternehmen Eva Stampaggi S r l nicht das sich das Recht vorbehält ohne zu Vorankündigungen oder Ersetzungen verpflichten zu sein für opportun gehaltene Änderungen vorzunehmen Alle Rechte vorbehalten Der vollständige oder teilweise Nachdruck ist ohne die ausdrück...

Reviews: