background image

© 2021 United States Stove Company

15

REFUELLING

CAUTION:

•  THE HOPPER AND STOVE TOP WILL BE HOT 

DURING OPERATION; THEREFORE, YOU 

SHOULD ALWAYS USE SOME TYPE OF HAND 

PROTECTION WHEN REFUELING YOUR STOVE. 

•  DO NOT TOUCH THE HOT SURFACES OF THE 

STOVE. EDUCATE ALL CHILDREN ON THE 

DANGERS OF A HIGH-TEMPERATURE STOVE. 

YOUNG CHILDREN SHOULD BE SUPERVISED 

WHEN THEY ARE IN THE SAME ROOM AS THE 

STOVE.

•  NEVER PLACE YOUR HAND NEAR THE AUGER 

WHILE THE STOVE IS IN OPERATION.

•  WE RECOMMEND THAT YOU NOT LET THE 

HOPPER DROP BELOW 1/4 FULL.

WARNING:

•  KEEP HOPPER LID CLOSED AT ALL TIMES 

EXCEPT WHEN REFILLING.

•  DO NOT OVERFILL HOPPER.

TAMPER WARNING

This wood heater has a manufacturer-set minimum low 

burn rate that must not be altered. It is against federal 

regulations to alter this setting or otherwise operate this 

wood heater in a manner inconsistent with operating 

instructions in this manual.

SHUTDOWN PROCEDURE

WARNING:

NEVER SHUT DOWN THIS UNIT BY UNPLUGGING 

IT FROM THE POWER SOURCE.

Turning your stove off is a matter of pressing the “POWER” 

button on the display board. The green light will turn back 

to red when the “POWER” button is pushed. The auger 

motor will stop, and the blowers will continue to operate 

until the internal firebox temperatures have fallen to a 

preset level.
1.  Your stove is equipped with a high temperature 

thermodisc. This unit has a manual reset thermodisc. 

This safety switch has two functions.

A.  To recognize an overheat situation in the stove and 

shut down the fuel feed or auger system.

B.  In case of a malfunctioning convection blower, the 

high-temperature thermodisc will automatically 

shut down the auger, preventing the stove from 

overheating.

NOTE: On some units, once tripped, like a circuit breaker, 

the reset button will have to be pushed before restarting 

your stove. On other units the thermodisc has no reset 

button and will reset itself once the stove has cooled. The 

manufacturer recommends that you call your dealer if 

this occurs as this may indicate a more serious problem. 

A service call may be required.
2.  If the combustion blower fails, an air pressure switch 

will automatically shut down the auger.

NOTE: Opening the stove door for more than 30 seconds 

during operation will cause enough pressure change to 

activate the air switch, shutting the fuel feed off. The stove 

will shut down and show “E2” on the two digit display. 

The stove has to fully shut down before restarting.

INTERIOR CHAMBERS

• 

Burn Pot - 

Periodically remove and clean the burn pot 

and the area inside the burn pot housing. In particular, 

it is advisable to clean out the holes in the burn pot to 

remove any build up that may prevent air from moving 

through the burn pot freely.

Over time ash or dust may accumulate on the blades 

of the circulation & exhaust fans. The fans should be 

inspected, periodically, and if any accumulation is 

present vacuumed clean as the ash or dust can impede 

the fans performance. It is also possible that creosote 

may accumulate in the exhaust fan therefore, this must 

be brushed clean. The exhaust fan can be found behind 

the left side panel (facing the front of the heater), the 

circulation fan can be found behind the right side panel. 

To access the igniter, remove the air inlet tube and cover 

(2 screws). The auger motor is located in the center rear 

of the unit. Note: When cleaning, take care not to damage 

the fan blades.
If a vacuum is used to clean your stove, we suggest 

using the AV15E AshVac vacuum. The AV15E AshVac is 

designed for ash removal. Some regular vacuum cleaner 

(i.e. shop vacs) may leak ash into the room.

DO NOT VACUUM HOT ASH.

OPERATION INSTRUCTIONS

Содержание KP60

Страница 1: ...ing or fire officials about permits restrictions and installation requirements in your area NEVER OPERATE THIS PRODUCT WHILE UNATTENDED CAUTION Please read this entire manual before you install or use...

Страница 2: ...installation and operation of the USSC KP60 pellet stove This heater meets the 2020 U S Environmental Protection Agency s crib wood emission limits for wood heaters sold after May 15 2020 Under speci...

Страница 3: ...and_____________________________________________ If no Date of inspection of existing venting system ________________________________________________________________ COMMISSIONING Confirm Hearth Pad I...

Страница 4: ...MUST BE PLUGGED INTO A 110 120V 60 HZ GROUNDED ELECTRICAL OUTLET DO NOT USE AN ADAPTER PLUG OR SEVER THE GROUNDING PLUG DO NOT ROUTE THE ELECTRICAL CORD UNDERNEATH IN FRONT OF OR OVER THE HEATER DO N...

Страница 5: ...or non combustible surface should be large enough to cover at least the area under the product and 6 153 mm beyond the front and beyond each side of the fuel loading and ash removal openings Floor pr...

Страница 6: ...heater must be electrically grounded to the steel chassis of the mobile home with 8 GA copper wire using a serrated or star washer to penetrate paint or protective coating to ensure grounding Vent mu...

Страница 7: ...ot use Type B Gas Vent pipe or galvanized pipe with this unit The pellet vent pipe is designed to disassemble for cleaning and should be checked several times during the burning season The pellet vent...

Страница 8: ...n airtight homes and mobile homes Be sure that the outside air vent has an approved cap on it to prevent rodents from entering Be sure to install in location that won t become blocked with snow etc 8...

Страница 9: ...de or outside of the house The through the wall installation is the least expensive and simplest installation Never terminate the end vent under a deck in an alcove under a window or between two windo...

Страница 10: ...ll with too much fuel and the fire will smother out To much air will result in a flame that is overactive or aggressive The flame in this situation is typically very blue at the bottom and resembles a...

Страница 11: ...ordance to the heat range setting However this speed can be manually operated by pressing the Draft Fan arrows up or down Draft Fan when pressed the display will show Df A which is automatic Press the...

Страница 12: ...the stove cycle between the preselected desired heat range setting 1 to 5 and the minimum heat range setting of 1 The T Stat will not turn the stove on and off When the desired room temperature has be...

Страница 13: ...reduced performance Store your pellets in a dry place DO NOT store the fuel within the installation clearances of the unit or within the space required for refuelling and ash removal Doing so could r...

Страница 14: ...A testing it was determined setting 1 achieved a medium burn rate under laboratory conditions Settings 3 4 will give you a higher heat output above medium If the door is opened while the stove is in o...

Страница 15: ...d like a circuit breaker the reset button will have to be pushed before restarting your stove On other units the thermodisc has no reset button and will reset itself once the stove has cooled The manu...

Страница 16: ...f chimney in use A qualified chimney sweep can perform this service It is also recommended that before each heating season the entire system be professionally inspected cleaned and if necessary repair...

Страница 17: ...of glass from the door frame 4 Replace the glass and gasket making sure the gasket runs the full perimeter of the glass edge 5 Re install the retainer and eight nuts and rope gasket using high tempera...

Страница 18: ...ets Check that all outside connections are clear of any obstructions Check the exhaust system clean as needed Checkthatthepressureswitchconnectiontothefireboxisfreeofashorclearofobstructions Auger sys...

Страница 19: ...he stove is in the Shut Down state waiting for the off button or for a 15 minute period after the stove was turned off or for the stove to cool down or for the door to be closed Flashing dash in Heat...

Страница 20: ...20 2021 United States Stove Company REPAIR PARTS 26 34 32 28 29 30 31 27 25 22 21 20 23 24 19 17 18 16 14 15 9 8 7 6 1 4 5 2 3 10 11 12 13...

Страница 21: ...Motor 1 25 28845 Motor Cover 1 26 28604 Back Panel 1 27 28889 Pressure Switch Bracket 1 28 80549 Vacuum Switch 1 29 80609 High Limit Thermodisc 1 30 80779 Digital Wall Thermostat 1 31 80780 IR Remote...

Страница 22: ...l help to ensure the correct items are ordered Before contacting customer service write down the model number and the serial number of this unit That information can be found on the certification labe...

Страница 23: ...______ Engineer Name _____________________________________ License No _________________________________________ Company ___________________________________________ Telephone No _______________________...

Страница 24: ...24 2021 United States Stove Company NOTES...

Страница 25: ...____________________ Service de 07 Date ______________________ Nom de l ing nieur _________________________________ N de licence ______________________________________ Compagnie ______________________...

Страница 26: ...N NOIR BLANC ROUGE BLEU ORANGE PRISE MOLEX AU CIRCUIT IMPRIM PCB PRINCI PAL BLANC NOIR ROUGE BLANC BLANC SOUFFLANTE DE DISTRIBUTION VENTILATEUR D VACUATION THERMISTOR VERT HAUTE Situ sur le bouclier t...

Страница 27: ...Tari re 1 19 28846 Support De Moteur De Tari re 1 20 80782 Ventilateur De Combustion 1 21 88308 Joint De Sou ante 1 22 80607 Allumeur 1 23 40867 Transition Ventilateur 1 24 80781 Moteur De Tari re 1 2...

Страница 28: ...2021 United States Stove Company 21 26 34 32 28 29 30 31 27 25 22 21 20 23 24 19 17 18 16 14 15 9 8 7 6 1 4 5 2 3 10 11 12 13 PI CES DE RECHANGE...

Страница 29: ...t deux fois par seconde Cela indique que le po le fonctionne normalement et qu une condition de temp rature excessive existe provoquant l arr t du combustible Indicateur de r glage du niveau de chaleu...

Страница 30: ...st me vis sans fin est bloqu ou il y a une vo te de combustible dans la tr mie qui emp che le combustible de s couler dans le syst me d approvisionnement vis sans fin PROBL ME CAUSE L allumeur automat...

Страница 31: ...propri taire sont sp cifiques votre appareil Lors de la commande de pi ces de rechange les informations contenues dans ce manuel vous aideront vous assurer que les bons articles sont command s Avant d...

Страница 32: ...verre N UTILISEZ PAS de nettoyants abrasifs N effectuez PAS le nettoyage lorsque la vitre est CHAUDE N essayez pas de faire fonctionner l appareil avec du verre bris Le verre de remplacement peut tre...

Страница 33: ...p cialement con ue pour le type de chemin e utilis Un ramoneur qualifi peut fournir ce service Il est galement conseill d inspecter de nettoyer et si n cessaire de r parer la totalit du syst me avant...

Страница 34: ...e d appeler le service de r paration 2 En cas de d faillance du ventilateur de combustion un interrupteur pneumatique interrompt automatiquement la tari re REMARQUE L ouverture de la porte du po le pe...

Страница 35: ...pot de combustion 2 Appuyez sur le bouton Marche Arr t Assurez vous que le voyant vert s allume 3 Ajustez la vitesse d alimentation au r glage souhait en appuyant sur le bouton Avance du niveau de ch...

Страница 36: ...ids cendres inf rieure 1 en poids et sel inf rieur 300 parties par million Les granul s mous contenant une quantit excessive de sciure de bois en vrac qui ont t ou sont mouill s r duiront les performa...

Страница 37: ...faire en sorte que le po le se programme entre le r glage pr s lectionn de la plage de chaleur d sir e 1 5 et le r glage de la plage de chaleur minimale de 1 Le T Stat n allumera ni ne teindra le po l...

Страница 38: ...itesse conform ment au r glage du niveau de chaleur Cependant cette vitesse peut tre r gl e manuellement en appuyant sur les fl ches haut et bas du ventilateur de tirage Draft Fan Lorsque le bouton Dr...

Страница 39: ...ant une dur e suffisante le pot de combustion se remplira avec trop de combustible et le feu s touffera Trop d air provoquera une flamme hyperactive ou agressive La flamme dans cette situation est g n...

Страница 40: ...de neige il est recommand que l installation soit plus grand que 3 pieds 0 91 m pour obtenir au dessus de la ligne de cong re Cette m me installation peut tre utilis e si votre chauffe eau est en dess...

Страница 41: ...corporelles les dommages de chauffage et annuler votre garantie ECHAPPEMENT HORIZONTALES INSTALLATION 1 Localisez votre po le granul s dans un endroit qui r pond aux exigences de ce manuel mais dans u...

Страница 42: ...tre achet s par ment INSTALLATION D VENT GRANUL S L installation doit comprendre un t de nettoyage pour permettre la collecte des cendres volantes et pour permettre le nettoyage p riodique du syst me...

Страница 43: ...pluie Lors du d m nagement de votre maison mobile toute ventilation ext rieure doit tre enlev e pendant le d placement de la maison mobile Apr s le d placement tous les vents doivent tre r install s...

Страница 44: ...des cendres La protection du plancher doit s tendre sous et 2 51 mm de chaque c t du t de chemin e pour une installation verticale int rieure Les installations canadiennes n cessitent un minimum de 1...

Страница 45: ...UPEZ PAS LA FICHE DE TERRE N ACHEMINEZ PAS LE CORDON LECTRIQUE SOUS DEVANT OU SUR LE PO LE NE FAITES PAS COURIR LE CORDON LECTRIQUE DANS LES ZONES DE PASSAGE ET NE LE COINCEZ PAS SOUS LES MEUBLES ATTE...

Страница 46: ...n date d inspection du syst me de ventilation existant ___________________________________________________________________ MISE EN SERVICE Confirmer l installation du tapis de foyer conform ment aux i...

Страница 47: ...r glage le plus bas 1 5 lbs hr Taille de Pellet peut effectuer le taux r el d alimentation en carburant et de br ler fois Taux d alimentation en carburant peut varier par autant que 20 Utiliser PFI c...

Страница 48: ...strictions et les exigences d installation dans votre r gion NE JAMAIS UTILISER CE PRODUIT SANS SURVEILLANCE MISE EN GARDE Veuillez lire l int gralit de ce manuel avant d installer ou d utiliser votre...

Отзывы: