Project # 22-753 Model: KP5522
Page | 7
Results
The integrated test run emission rate for test Run 1 was measured to be
1.5 g/hr
with a
Higher Heating Values efficiency of
76%
and a CO emission rate of
0.15 g/min
. The
calculated first hour particulate emission rate was
2.8 g/hr
. The United States Stove
Company Model KP5522 Pellet-Fired Room Heater meets the 2020 PM emission
standard of ≤ 2.0 g/hr per CFR 40 part 60, §60.532 (b).
Detailed individual run data can be found in Appendix A submitted with this report.
Summary Table
EPA Application Table
Run
Number
Date
Segments
Run
Time
(min)
Heat
Output
(BTU/hr)
1st Hr
Emissions
(g/hr)
Integrated
Total (g/hr)
CO
Emissions
(g/min)
Overall
CO
Emissions
(g/min)
Heating
Efficiency
(%HHV)
Overall
Heating
Efficiency
(%HHV)
Setting
BR
1
2/18/2022
H
2.26
60
32591
2.8
1.5
0.21
0.15
77%
76%
M
1.58
120
22312
0.17
76%
L
0.97
180
13640
0.12
76%
OA
1.39
360
19708
0.15
76%
Содержание KP5522-P
Страница 11: ...Project 22 753 Model KP5522 Page 10 Appliance Front Appliance Left...
Страница 12: ...Project 22 753 Model KP5522 Page 11 Appliance Right Appliance Rear...
Страница 14: ...Project 22 753 Model KP5522 Page 13 Pellet Fuel Analysis...
Страница 17: ...Project 22 753 Model KP5522 Page 16 Sealed Unit...
Страница 19: ...Appendix A...
Страница 66: ...Project 22 751 Model Charnwood Skye E700 Page 16 Tunnel Schematic...
Страница 100: ......
Страница 101: ......
Страница 102: ......
Страница 103: ...Appendix B...
Страница 127: ...2022 United States Stove Company 23 NOTES...
Страница 128: ...24 2022 United States Stove Company NOTES...
Страница 129: ...2022 United States Stove Company 25 NOTES...
Страница 160: ......
Страница 161: ......
Страница 162: ......
Страница 163: ...Appendix C...
Страница 171: ......
Страница 172: ......
Страница 174: ......
Страница 175: ......
Страница 181: ......
Страница 182: ......
Страница 189: ...Appendix E...
Страница 192: ...1 1 2 2 3 3 4 4 A A B B A B C...