![background image](http://html1.mh-extra.com/html/united-states-stove-company/kp5522-p/kp5522-p_manual_4040263063.webp)
Run 1.xlsm
PM
R
– Average particulate emissions for full integrated test run, g/hr
ASTM E2779 equation (5)
PM
R
= 60 (E
T
/
θ
)
Where,
E
T
= Total particulate emissions, grams
θ
= Total length of full integrated test run, min
Sample Calculation:
E
T
(Dual train average) = 8.99 g
θ
=
360 min
PM
R
= 60 x ( 8.99 / 360 )
PM
R
=
1.50
g/hr