background image

15

38

39

41

40

44

43

47

45

48

49

42

46

50

PARTS DIAGRAM AND LIST

N/S = Not Shown
P = Items designated for model 1800

IMPORTANT NOTE:

When ordering repair parts, a color code (G) should be placed aft er the part 

number of any part that is painted.

Key

Description

Part #

Qty

1

Feed Door Assy. (w/Rope Gasket)

69091

1

2

Door Handle

24179

2

N/S

Lock Nut, 1/2-13

83444

2

N/S

Washer

83835

2

3

Spring Handle

89574

4

4

Feed Door Latch

23786

1

5

Ash Door Assy. (w/Rope Gasket)

68880

1

6

Draft  Cap

23859

1

7

Ash Door Latch

23823

1

N/S

Hinge Pin, 5/16” x 1”

C21399

4

8

Shaker Handle

69005

1

9

Bracket, Shaker Handle

24204

1

10

P

Ash Pan
Ash Pan - 1800

68882

68919

1

1

11

P

Grate Retainer
Grate Retainer - 1800

40312

40337

2

2

12

Shaker Bar

891341

1

13

P

Shaker Grate Section
Shaker Grate Section - 1800

40314

.............

5

7

14

P

Back Liner
Back Liner - 1800

40313

40339

1

1

15

P

Front Liner
Front Liner - 1800

40344

40338

1

1

16

P

Full Firebrick (4-1/2 wide x 9 tall x 1-1/4 thick)
..............................................................................

89066

.............

16

22

17

P

Half Firebrick (2-1/4 wide x 9 tall x 1-1/4 thick)
..............................................................................

891414

.............

3

2

18

Slide Baffl

  e

24231

1

19

P

Baffl

  e Rod

Baffl

  e Rod - 1800

86603

86607

1

1

20

Lock Nut, 1/2-13

83444

2

21

Gasket, Flue Collar

88032

1

22

Flue Collar

40246

1

23

P

Flue Collar Ring
Flue Collar Ring - 1800

22761

23958

1

1

24

Smoke Curtain

23800

1

25

Smoke Door Clip

23787

2

26

Carriage Bolt, 1/4-20 x 1-1/4 Long

83445

2

27

Kep Nut, 1/4-20

83250

2

28

P

Cabinet Side, Left 
Cabinet Side, Front Left  - 1800

68821

68962

1
1

29

P

Insulation, Side
Insulation, Side - 1800

C98771

23977

2
2

30

Insulation Retainer

83884

41

31

P

Cabinet Side, Right
Cabinet Side, Right - 1800

68822

68961

1

1

N/S

Cabinet Side, Back - 1800

69002

2

32

Receptacle, Snap-In

80351

1

33

P

Cabinet Back
Cabinet Back - 1800

69573

69613

1

1

34

P

Insulation, Panel
Insulation, Back - 1800

C98871

23978

2

2

P

Insulation, Top - 1800

23979

2

35

P

Cabinet Top
Cabinet Top - 1800

69088

68964

1
1

Key

Description

Part #

Qty

36

P

Front Filler
Front Filler - 1800

23817

24190

1

1

37

P

Draft  Cover
Draft  Cover - 1800

23818

24508

1

1

38

Room Blower - 800 CFM

80530

2

39

Blower Gasket

88127

2

40

Tinnerman Clip, 1/4-20

83340

8

41

Bolt, 1/4-20 x 3/4

83339

8

42

Conduit Assembly (5ft )

69578

2

43

Honeywell Limit Control

80145

1

44

Conduit Assembly (1ft )

68859

1

45

Junction Box

25625

1

46

Insulation (5” x 5”)

25626

1

47

Rocker Switch

C42373

1

48

Romex Cable Clamp

80362

1

49

Fan Center Control

80130

1

50

Water Coil Access Cover

23819

1

Содержание 1602G

Страница 1: ...furnace must be installed by a qualified technician Keep these instructions for future reference 851768B 1908E Model 1602G 1802G Wood or Coal Gravity Style Up Flow Supplemental Furnace United States S...

Страница 2: ...this appliance in any way other than specified in these instructions Doing so may void your warranty LOCATING YOUR FURNACE The furnace is to be installed maintaining the clearances speci fied in the...

Страница 3: ...The amount of draft in your chimney depends on the length of the chimney local geography nearby obstructions and other factors Too much draft may cause excessive tempera tures in the appliance Inadequ...

Страница 4: ...e and should clean it This pipe should be cleaned at least once or twice during the heating season DO NOT CONNECT TWO HEATERS TO THE SAME CHIM NEY FLUE The National Fire Prevention Association recom m...

Страница 5: ...on this system should be made the full width of the furnace plenum in order to properly direct the air into the dis tribution ducts INSTALLATION 2 Extending the hot air duct from the furnace into the...

Страница 6: ...fire places and wood burning furnaces need enough oxygen for complete combustion of their fuels The incomplete combustion that takes place when a furnace is air starved causes carbon monoxide CO to be...

Страница 7: ...s 4 Spring Handles DISTRIBUTION BLOWER ACC 1 Remove all contents and insure that all components are present for assembly See the part list below 2 Begin by attaching the blowers to the unit Insert a c...

Страница 8: ...a cleaner installation 2 800 CFM Blower 2 Gasket Blower 8 Tinnerman Clip 1 4 20 8 1 4 20 x 3 4 Bolt 2 Conduit Assembly 5ft 1 Honeywell Limit Control 1 Conduit Assembly 1ft 1 Junction Box 1 Insulation...

Страница 9: ...t of the furnace Then mount and secure the draft blower to the adapter with the three 10 24 Kep nuts Plug the blower into the outlet on the front of the furnace 1 Draft Blower 1 Draft Blower Adapter 2...

Страница 10: ...int thinners or as phalt products 6 Materials containing asbestos 7 Construction or demolition debris 8 Railroad ties or pressure treated wood 9 Manure or animal remains 10 Salt water driftwood or oth...

Страница 11: ...he rear 3 Always keep the ash pit clean If the fire goes out or does not hold overnight look for 1 Poor draft 2 Incorrect damper settings 3 Improper firing methods for coal being used 4 More combustio...

Страница 12: ...s the combustion process completely condensed In the case of woodstoves this would as sume the exhaust gases are room temperature when leaving the system and therefore calculations using this heating...

Страница 13: ...imney is of adequate height E Make sure you re not suffocating the fire with excessive amounts of unburned wood F Slide baffle should be pulled out prior to load door opening 4 Problem Distribution bl...

Страница 14: ...14 PARTS DIAGRAM 11 12 13 16 15 17 14 7 10 5 2 3 6 32 31 4 3 2 1 37 3 8 9 24 26 25 27 17 16 3 19 18 20 28 29 30 36 21 22 34 34 35 23 33...

Страница 15: ...607 1 1 20 Lock Nut 1 2 13 83444 2 21 Gasket Flue Collar 88032 1 22 Flue Collar 40246 1 23 P Flue Collar Ring Flue Collar Ring 1800 22761 23958 1 1 24 Smoke Curtain 23800 1 25 Smoke Door Clip 23787 2...

Страница 16: ...and or filter box should be incorporated into your furnace installation A cold air return or filter box will increase the life of your blow ers and offer filtered distribution air for your home U S S...

Страница 17: ...The installation is now ready to be plumbed to your existing hot water system Choose one of the three methods described in the Hot Water Coil instructions 6 Remove knockouts from the access panel and...

Страница 18: ...ially if it has caked over or formed a crust But be careful not to mix the coal as this increas es the chances of forming clinkers When shaking the grate s be gentle Just a few short movements a coupl...

Страница 19: ...se does not become too cold It is important that you begin banking early enough before retiring or leaving that you can make necessary adjustments after the fire is well established To revive a coal f...

Страница 20: ...a safe place for future reference When placing an order or for warranty claims please provide the following information found on the Certification Plate located below the ash door PART NUMBER PART DES...

Отзывы: