background image

Warranty

22

United Spa Controls One Year Limited Warranty on Spa Controls

United Spa Controls warrants, to the original purchaser, the Spa Control Equipment against 
defects in materials or workmanship for a period of one year from date of purchase. The 
obligation of this warranty shall be limited to repairing or replacing the part, which in the 
opinion of the company shall be proved defective in materials or workmanship. This limited 
warranty does not include the limitations described below.

Limitations of Coverage:

 This warranty does not cover failures due to: damage, freezing, 

power failure, power reduction, unusual atmospheric conditions, rust or corrosion, repairs 
necessary because of operator negligence improper re-packaging and damage incurred in 
shipping. This warranty does not cover thermostat calibration, plumbing, expendable items 
(gaskets, o-rings, 

fi

 lter cartridges).

Acts Invalidating Warranty:

 This warranty shall be invalid if this equipment has been 

subjected to alterations, misuses or abuse, improper water chemistry maintenance or used 
for commercial purposes (used in other than single family household purposes). Misuse 
and abuse shall include application installation or operation outside of the environment and 
limitations for which it was designed, or other than in accordance with United Spa Controls 
or the spa manufacturer printed instructions. This warranty shall also be invalid if the spa 
equipment is damaged by earth or ground 

fi

 ll movement, 

fi

 re, 

fl

 ood, wind, lightning, by Act of 

God, accident, or by intentional, reckless, or negligent acts any person.

Warranty Performance: 

All warranty service and/or replacement of parts must be performed 

by an individual or service company that has been authorized by United Spa Controls. The 
purchaser may obtain the bene

fi

 ts of warranty coverage on a failed part by having the 

servicing company remove the part and send it for inspection, along with proof of purchase 
and 

fi

 eld service report, freight pre-paid, to: United Spa Controls 2480-B N. Glassell St., 

Orange, CA 92865 If the failure is covered by the warranty, there will be no charge for the 
repaired or replacement part. Removal charges, re-installation charges, and freight charges 
to and from United Spa Controls of the failed part shall be the purchaser’s responsibility. 
Any such warranty replacement or repair shall be subject to the terms and condition of this 
warranty for the remainder of the original period of coverage. United Spa Controls reserves 
the right to inspect the malfunction or defect on location.

Disclaimers, Legal Remedies:

 United Spa Controls shall not be liable for the loss of use 

of any equipment. This warranty is in lieu of all other expressed warranties obligations or 
liabilities, any implied warranty of merchantability, shall be limited in duration to the duration 
of this written limited warranty. Any action for breach of warranty hereunder, including but 
not limited to, any applied warranty of merchantability must be brought within a period of 12 
months from date of purchase. Some states do not allow limitations on how long an implied 
warranty lasts, so the above limitation may not apply to you. No agent, representative, dealer 
or employee of the company has the authority to increase or alter the obligations of this 
warranty. In no case shall the company be liable for any incidental or consequential from state 
to state. United Spa Controls does not authorize any person or company to assume for it 
any other obligation or liability in connection with the sale, application, engineering, damages 
for breach of this of any other warranty, expressed or implied, whatsoever. Some states do 
not allow the exclusion or limitation of incidental or consequential damages, so the above 
limitation or exclusion may not apply to you. This warranty gives you speci

fi

 c legal rights, and 

you may also have other rights which vary installation use, removal, return, or replacement of 
it’s systems: and no such representations are binding on United Spa Controls.

Содержание T7

Страница 1: ......

Страница 2: ...opside s programming as mis programming can result in malfunction or possible damage Please contact your dealer or a locally licensed service center for service and technical support Warranty Disclaim...

Страница 3: ...3 T7 User Settings Menu Tree 14 Heating Modes Standard and Economy 15 T7 Filtration Cycle Operation 15 Changing Filtration Cycle Settings 16 Changing the Temperature Display Setting 16 Changing the Bu...

Страница 4: ...VERTISSEMENT POUR VITER QUE LES CHEVEUX OU UNE PARTIE DU CORPS PUISSENT TRE ASPIR S NE PAS UTILISER UNE CUVE DE RELAXATION SI LES GRILLES DE PRISE D ASPIRATION NE SONT PAS TOUTES EN PLACE 3 Warning Pe...

Страница 5: ...ssibly pregnant women should consult a physician before using a spa or hot tub AVERTISSEMENT LES FEMMES ENCEINTES QUE LEUR GROSSESSE SOIT CONFIRM E OU NON DEVRAIENT CONSULTER UN M DECIN AVANT D UTILIS...

Страница 6: ...uction ATTENTION LA TENEUR DE L EAU EN MATI RES DISSOUTES DOIT TRE CONFORME AUX DIRECTIVES DU FABRICANT 14 Hyperthermia occurs when the internal temperature of the body reaches a level several degrees...

Страница 7: ...e the hole needed for installation Simply drill the hole in the center of where you ll be installing the topside Topside Installation Location The T7 topside should be installed on an outward facing e...

Страница 8: ...firmly to assure a firm bond NOTE Do NOT connect disconnect the T7 topside while the control box has power going to it Always make sure the power is shut off at the breaker before removing installing...

Страница 9: ...th the descriptions of the items that will be referenced throughout this user s guide A video introduction to the T7 topside can be found on YouTube at the following URL http youtu be T_kGXIPwPzU 1 2...

Страница 10: ...next filtration cycle start which defaults to 1 hour T7 Topside Configuration Codes There are five codes that can be configured Each code has a number of options the code can be set to By default all...

Страница 11: ...triction Option 3 50A Operation No heat with P 2 Option 4 40A Operation No heat with P 2 and Aux Option 5 20A 120V Operation or 30A 240V Operation No heat with anything other then P 1 Lo Speed Code 5...

Страница 12: ...not be able to set Code 5 to Option 4 if Code 1 is set to Option 2 and or Code 2 is set to Option 1 Entering The T7 Topside s Programming Mode Once you ve gone over the code chart and have chosen the...

Страница 13: ...for that code While in programming mode the same 15 second time out applies if you take longer then 15 seconds to change a code s selected option or cycle through to the next code all settings will be...

Страница 14: ...ons on getting into maneuvering and making and saving changes to these settings which will be referenced throughout this section Entering the User Settings Menu Step 1 Press and hold for 6 seconds unt...

Страница 15: ...Hours Per Day 12 Hours Per Day to 24 Hours Per Day or Start At Once Start In 12 Hours to Start In 24 Hours or Heating Mode Filtration Cycles Per Day Hours Of Filtration Per Day Next Filtration Cycle S...

Страница 16: ...n Economy Mode Note If you have a Circulation Pump that operates 24 hours a day economy mode will not effect heating behavior and the control will continue to heat as needed to maintain the set temper...

Страница 17: ...rs 0 through 12 may be selected If the T7 is set for 1 cycle a day 0 through 24 hours of filtration may be selected Next Filtration Cycle Start Time or The number of hours until the next filtration cy...

Страница 18: ...displays the currently set temperature for approximately 4 seconds While the currently set temperature is being displayed Press to increase the set temperature You can press and release right away to...

Страница 19: ...mp Systems Press to toggle between Lo Speed Hi Speed Off Whenever Hi Speed of Pump 1 is running the Jets 1 indicator light will be lit Likewise whenever Lo Speed of Pump 1 is running the Jets 1 indica...

Страница 20: ...en On Off Dual Speed Pump 2 Operation Press to toggle between Lo Speed Hi Speed Off In the Single Speed Pump 2 configuration the Jets 2 indicator light will be lit when Pump 2 is on In the Dual Speed...

Страница 21: ...0 minutes of operation Operating the Spa Light To operate the spa light simply press to toggle between On Off The light will automatically shut off after 4 hours of operation Note If your spa also has...

Страница 22: ...drops to at least 103 F 39 C press and hold the Temp Down button for 10 seconds to reset Hardware Overheat The hi limit sensor is reading over 116 F 46 C Once the temperature drops to at least 103 F 3...

Страница 23: ...tion along with proof of purchase and field service report freight pre paid to United Spa Controls 2480 B N Glassell St Orange CA 92865 If the failure is covered by the warranty there will be no charg...

Страница 24: ...United Spa Controls 2480 A N Glassell St Orange CA 92865 Web UnitedSpaControls com E mail sales unitedspacontrols com Phone 714 282 1117 Fax 888 715 0286 2015 United Spa Controls All rights reserved...

Отзывы: