- 5 -
VOLTAGE LEVEL ACTIVATION HOOKUP
WHEN THE ALARM OUTPUT VOLTAGE IS RELAY DRIVEN, YOU MUST ADD A 1K RESISTOR
ACROSS ALARM OUTPUT TERMINALS. HOOK UP DIALER AS SHOWN BELOW.
PP-1
STANDBY
BATTERY
(optional)
ALARM CONTROL PANEL
W/VOLTAGE TRIGGER
ALARM OUTPUT
12VDC
+
-
ALARM
+
-
INSTALL 1K OHM
RESISTOR HERE IF
ALARM OUTPUT IS
RELAY DRIVEN
1K
Make sure unit is set to “OFF” prior
to wiring and phone line hook-up.
Match the power cables colored wires to the corresponding
outputs on the alarm panel. Do the same for the telephone
cable.
RED
BLACK
YELLOW
WHITE
RED
GREEN
TEL LINE
Alarm when voltage goes
from 0 to +V (5 to 28Vmax).
Program for N.C. operation.
Alarm when voltage goes
from +V (5 to 28Vmax) to 0.
Program for N.O. operation.
Note: You may either program for momentary or
continuous voltage activation. In continuous mode, make
sure that the alarm condition is maintained for minimum 7
minutes to allow all numbers to be dialed. Pressing the M
button immediately resets the dialer.