Programming Tone/Pulse and PBX

 

1. Press the “M” key until “PROGRAM: NUMBERS” appears in the LCD, then press “2”. 
2. Press “1” (YES) at the “PROGRAM: T-LINE” prompt. 
3. Press “1” (TONE) for touch tone phone service. 

Press “2” (PULSE) for pulse (rotary) phone service. 

4. After selecting TONE or PULSE, the LCD will display “PROGRAM: PBX”. 
5. Press “1” (ON) to set for PBX phone system, then enter the PBX digit 0-9 (This will allow the unit to 

dial the PBX digit, wait for a dial tone, then dial the stored number). 
Press “2” (OFF) to set for regular phone system (Waits for a dial tone, then dials the stored number). 

 
Programming Exit and Entry Delay

 

1. Press the “M” key until “PROGRAM: NUMBERS” appears in the LCD, then press “2” three times. 
2. Press “1” (YES) at the “PROGRAM: CHANNEL” prompt. 
3. Press “1” (ON) for a 60 second Exit delay (This provides a 60 second exit delay, after the AVD-45b is 

set in the “OPERATE” mode, before the unit will react to a sensor trip, allowing time to exit). 
Press “2” (OFF) for no Exit delay (This will allow the unit, when set in the “OPERATE” mode, to react 
immediately to a sensor trip. 

4. After selecting the Exit delay, the LCD should display “ENTRY DELAY”. 
5. Press “1” (ON) for a 20 second Entry delay (This provides a 20 second entrance delay, after any exit 

delay time has elapsed, before the unit will react to a sensor trip, allowing time to shut off).  

6. Press “2” (OFF) for no Entry delay (This will allow the unit to react immediately to a sensor trip, after 

any exit delay has elapsed. 

NOTE: When using the AVD-45b with an alarm panel that already has Exit/Entry delays 
programmed, EXIT and ENTRY should be programmed for “OFF” unless an additional delay is 
needed.

PROGRAMMING THE DIALER

Содержание AVD-45b

Страница 1: ...United Security Products Model AVD 45b Automatic Voice Dialer Installation and Instruction Manual Patents Pending...

Страница 2: ...mmed to sequentially dial any combination of four standard telephone most cellular telephones alpha voice pagers and or numeric pagers The dialer features busy line and no answer detection to ensure t...

Страница 3: ...1 5 6 2 3 AVD 45b Automatic Voice Dialer AVD 45b PANEL DISPLAY 9V ALKALINE BATTERY LCD Speaker MIC Keypad Mode Program Pause TEL LINE 12V STANDBY BATTERY RED BLACK YELLOW WHITE 12V ALARM REAR VIEW BA...

Страница 4: ...omatically dials all numbers even after the alarm input is restored to non alarm To stop dialing you must press the M button to switch the unit to the OFF mode 2 In continuous mode the alarm condition...

Страница 5: ...ne line hook up Match the power cables colored wires to the corresponding outputs on the alarm panel Do the same for the telephone cable RED BLACK YELLOW WHITE RED GREEN TEL LINE Alarm when voltage go...

Страница 6: ...sage two times per call to ensure that a full message is delivered If the phone number is busy or not answered within 8 rings the AVD 45b will automatically dial the next programmed number Assuming an...

Страница 7: ...art of the LCD Make sure the unit is in the PROGRAM mode If it is not press the MODE M button to change modes To store voice telephone numbers in memory locations 1 through 4 see p 9 for pagers 1 At t...

Страница 8: ...nge a programmed number press the MODE M button until PROGRAM NUMBERS prompt appears enter 1 YES and enter the number then the location see example 1 or 2 above To completely erase numbers already sto...

Страница 9: ...sign at the end of the numeric message for proper transmission Also make sure that the total length of the number including pauses and does not exceed 28 characters 5 Finally press the PROGRAM PAUSE P...

Страница 10: ...nter the wrong number or wish to change a programmed number press the MODE button until PROGRAM NUMBERS prompt appears enter 1 YES and enter the number then the location see example 1 or 2 above 5 5 5...

Страница 11: ...CHANNEL prompt 3 Press 1 ON for a 60 second Exit delay This provides a 60 second exit delay after the AVD 45b is set in the OPERATE mode before the unit will react to a sensor trip allowing time to e...

Страница 12: ...outgoing message OGM of up to 16 seconds may be programmed into the AVD 45b Once recorded this message will be repeated during activation 2 times in sequence starting with Location 1 to each number d...

Страница 13: ...urn to the program mode To verify telephone numbers and OGM with phone line connection NOTE A complete test should be performed in the OPERATE mode to ensure proper operation 1 Before conducting an ac...

Страница 14: ...go through the next programmed Location repeating the same process The AVD 45b is now ready for operation Utilizing the EEPROM and CPU memory cell components the AVD 45b will retain its memory in the...

Страница 15: ...into the unit OPTIONAL BACKUP To ensure continuous operation during power outages hookup to a 12VDC backup battery pack as recommended CAUTION Do not use the dialer if a gas leak is suspected or duri...

Страница 16: ...designed to provide reasonable protection against such interference in a residential installation User Instructions If this equipment does cause interference to radio or television reception which ca...

Страница 17: ...s without a programmer Voice chip technology no tape required Ability to program up to 10 2 second pauses and pound for pager dialing Returns to call unanswered numbers 2 X 16 character LCD window Int...

Страница 18: ...AC DC ADAPTOR 500mA Plugs into regular 110VAC outlet to provide the dialer with the required 12VDC primary power PP 1 BACKUP BATTERY PACK Plugs into 12V Standby Battery jack Built in rechargeable bat...

Страница 19: ......

Страница 20: ......

Отзывы: