- 11 -
Programming Tone/Pulse and PBX
1. Press the “M” key until “PROGRAM: NUMBERS” appears in the LCD, then press “2”.
2. Press “1” (YES) at the “PROGRAM: T-LINE” prompt.
3. Press “1” (TONE) for touch tone phone service.
Press “2” (PULSE) for pulse (rotary) phone service.
4. After selecting TONE or PULSE, the LCD will display “PROGRAM: PBX”.
5. Press “1” (ON) to set for PBX phone system, then enter the PBX digit 0-9 (This will allow the unit to
dial the PBX digit, wait for a dial tone, then dial the stored number).
Press “2” (OFF) to set for regular phone system (Waits for a dial tone, then dials the stored number).
Programming Exit and Entry Delay
1. Press the “M” key until “PROGRAM: NUMBERS” appears in the LCD, then press “2” three times.
2. Press “1” (YES) at the “PROGRAM: CHANNEL” prompt.
3. Press “1” (ON) for a 60 second Exit delay (This provides a 60 second exit delay, after the AVD-45b is
set in the “OPERATE” mode, before the unit will react to a sensor trip, allowing time to exit).
Press “2” (OFF) for no Exit delay (This will allow the unit, when set in the “OPERATE” mode, to react
immediately to a sensor trip.
4. After selecting the Exit delay, the LCD should display “ENTRY DELAY”.
5. Press “1” (ON) for a 20 second Entry delay (This provides a 20 second entrance delay, after any exit
delay time has elapsed, before the unit will react to a sensor trip, allowing time to shut off).
6. Press “2” (OFF) for no Entry delay (This will allow the unit to react immediately to a sensor trip, after
any exit delay has elapsed.
NOTE: When using the AVD-45b with an alarm panel that already has Exit/Entry delays
programmed, EXIT and ENTRY should be programmed for “OFF” unless an additional delay is
needed.
PROGRAMMING THE DIALER