3. Connecting the electrical wiring to the charging station.
a. Remove the Charing Station front cover by unscrewing screws
Figure 2-13. Four Cap screw locations to remove the Charging Station Cover
Caution:
The LED pipe is attached to the charging station front cover. When front cover is
removed, place the front cover on the surface with front cover down and LED pipe
up. Placing front cover on LED pipe might damage or break LED pipe.
18
b. With the front cover placed to the side, use Philips screwdriver to release terminal screws
of the NEMA 6-50 or 14-50 Plug cable. Loosen the Strain Relief Fitting for the NEMA 6-50 or
14-50 Plug and Remove the Plug. Remove the Strain Relief connector.
c. Insert the wire end passing through the conduit and insert them into the input wiring
hole. (Use Red wire for L1, Black wire for L2, Green wire for G). Attach the copper wire on the
corresponding terminal block. Use the following wire and torque force when connecting to
input terminal block.