30A Circuit Rating: To support 24A (5.76 kW) maximum Charging Station output
20A Circuit Rating: To support 16A (3.84 kW) maximum Charging Station output
The Charging Station Default Factory Maximum Current Output Setting is 40A (9.6 kW) for use
with a 50A Circuit Rating. To adjust the Maximum Current Output Setting when using a 40A or
30A or 20A Circuit Rating:
1. Place the Charging Station on a flat surface, front cover up.
2. Remove the Charing Station front cover by loosening the (4) Cap screws at each corner of the
charging station.
Figure 2-1. Four screws locations to remove the Charging Station Cover.
3. With the front cover placed to the side, locate the DIP switch on the charging station circuit
board. The DIP switch is a 3-position switch on the main circuit board, located directly to the
left of the LED.
Caution:
The LED pipe is attached to the charging station front cover. When front cover is
removed, place the front cover on the surface with front cover down and LED pipe
up. Placing front cover on LED pipe might damage or break LED pipe.
13