EN
34/64
USER INTERFACE (3/5)
MAIN SWITCH
LED INDICATORS
STATUS
Causes
Solutions
Continuous green
Normal
Slow flashing green
Standby
Continuous red
Defective power
generator
Send the product back to Aftersale service
Overconsumption 5 times
Reduce connected devices consumption.
Slow flashing red
Battery low voltage
protection
Charge your battery
Reduce connected devices consumption.
Check your wiring (cables, terminals,
tightening)
Replace your battery if it is deficient.
Quick flashing red
Battery high voltage
protection
Check that the connected battery voltage is
compatible with the inverter.
Check your charging circuit (charger, solar,
alternator..)
Replace your battery if it is deficient.
Intermittent
flashing red
Over temperature
Reduce connected devices consumption.
Improve ventilation. Choose a well-ventilated
area.
ON
OFF
REMOTE
Содержание UNIPOWER 800.12 PRO