Chapter 5.  COMMUNICATION 

 

5.1 INSTALLATION 
 

The RS-232 port of PT630 can communicate with the serial port of a host computer. There are 
two ways to carry out communication sessions: 
 
(1) LOCAL   : Directly connect to the serial port of your computer system. 
(2) REMOTE  : Connected by two attached modems and one telephone line. 
 

 

 

5.1.1 LOCAL CONNECTION:

 

 

In the Local connection method, the PT630 is directly connected by a null modem cable to the 
serial port of the host computer. This is the way to 

download 

or 

upload

 files 

from/

to

 

your 

PT630. Note that the communication parameters must be matched on your PT630 and host 
computer, otherwise, the communication will fail. 

 

 

CONNECTING THE PT630 TO A HOST COMPUTER

 

 

Host 

Computer 

9 Pins

 

PT630 

 

2 RXD  

3 TXD 

3.TXD  

2 RXD 

5 GND 

5 GND 

7.RTS 8 

CTS 

8 CTS 

 

7 RTS 

 

 
When the flow control is set to CTS/RTS, the CTS (RTS) signal of one end is necessary to be 
linked to the corresponded RTS (CTS) on the other end. 
 

5.1.2 REMOTE CONNECTION: 

Содержание PT630

Страница 1: ...PT630 Operation Guide Page 1 of 41 ______________________________________________________ PT630 Portable Terminal Operation Guide V1 0...

Страница 2: ...de 11 3 2 3 Supervisor Mode 17 CHAPTER 4 HARDWARE OVERVIEW 28 4 1 INTRODUCTION 28 4 2 FEATURES 29 4 3 I O PORTS 29 4 2 1 The PT630 has three interface ports 29 4 2 2 Scanner 29 4 3 3 PT630 CHARGING CO...

Страница 3: ...ttery and a back up lithium battery which retains the data stored in RAM and real time clock when the main battery is drained The PT630 has a 128x64 pixel backlit graphic LCD display an integral 27 ke...

Страница 4: ...zation The table below shows hexadecimal values assigned to each key KEY VALUE KEY VALUE KEY VALUE KEY VALUE KEY VALUE CLR 08H 2DH 3DH M 4DH Y 59H ENTER 0DH 2EH 3FH N 4EH Z 5AH 10H 2FH 40H O 4FH 5BH 1...

Страница 5: ...subsystem allows users to set and obtain system date and time from the Real Time Clock Integrated Circuit IC in the PT630 1 2 5 Bar Code Input Port The PT630 has a built in barcode decoder The termin...

Страница 6: ...n the PT630 are classified into resident and transient categories the PT630 operation can not decipher the difference between them The only difference is the location of the executable files For resid...

Страница 7: ...ram controls the PT630 When the portable terminal is powered up EXEC performs the power on test POT EXEC proceeds to verify if the PT630 should make a warm or cold booting A warm boot resets the syste...

Страница 8: ...system flags Start flag and Save NOT OK flag which will be verified each time the unit is turned on 3 When the Start flag verification fails it indicates that there is probably a defective RAM chip or...

Страница 9: ...ier key pressing to input numbers When the unit is off pressing the key will turn on the unit On the other hand when the unit is on it is needed to press and hold down the key for about one second in...

Страница 10: ...on keys The keypad layout of available keys on command mode is shown on right picture There are three hot key functions and the usage of each function is described below LCD Backlit On Off Hit Key to...

Страница 11: ...of the executable applications to run in the portable terminal via the keypad or host command sequence After the Warm Start the PT630 enters the Ready mode and shows the Ready mode screen as shown lef...

Страница 12: ...input from scanning bar code labels or key press will be sent to the portable terminal RS 232 port In order to carry out a successful file transfer communication parameter setting such as baud rate d...

Страница 13: ...it allows the user to create a data entry application program by simply specifying field prompt type length input method and delimiter etc without having to write a comprehensive application program F...

Страница 14: ...es to display a program or binary file only unintelligible characters will be seen When selecting the TYP command the PT630 allows the user using or key to select an existence file then pressing ENT T...

Страница 15: ...4 hour system in the format HH MM SS hours minutes seconds 3 2 2 8 2 SCANNER SCANNER The bar code input interface of the PT630 is compatible to all major bar code scanners that are available in the ma...

Страница 16: ..._________________________ 3 2 2 8 3 DISPLAY Enable Disable whether to show the Power on LOGO Power on LOGO enabled is the default setting 3 2 2 8 4 KEYPAD Setup up case and low case Alpha character in...

Страница 17: ...llowing functions 1 DEV Device Configuration 2 TERM Terminal Configuration 3 MEM Memory Configuration 4 FORM FormCaching Define 5 PWR Set Resume Auto Off Alarm of program 6 PSWD Password Change 7 SYS...

Страница 18: ...ODE when selecting Option 3 BARCODE in the Supervisor Mode Device Configuration menu the LCD will display the BARCODE Setup as shown below BARCODE SETUP CODE 39 ON Press or to toggle between settings...

Страница 19: ...or The PT630 will operate as a dumb ASCII terminal when the user select this feature and disable the FormCaching menu When the TERM SETUP menu shown below appears on the PT630 LCD proceed to set up th...

Страница 20: ...the termination character The termination character can be set as LINE Line termination CR 0D hex PAGE Page termination CTRL Z 1A hex BOTH Line termination and page termination both 3 2 3 3 Memory Co...

Страница 21: ...mode menu When FormCaching is enabled the PT630 will first ask the user to specify data fields in four categories including field prompt data length and data type and device type After defining all da...

Страница 22: ...T630 FORM DAT stores the data as entered by the user after FormCaching is invoked The PT630 will not allow the user to redefine the data fields in FormCaching once the FORM DAT has been created The fi...

Страница 23: ...SUME 2 AUTO OFF 3 ALARM 1 RESUME When the Resume function is enabled the PT630 will resume program execution from the last turn off point when it is powered on again The default setting is ON enabled...

Страница 24: ...enter Shutdown mode if the PT630 has been idle for the specified timeout period as set in AUTO OFF Shut Down In Shutdown mode the main power is cut off from the PT630 excluding its RAM and Real Time C...

Страница 25: ...lashROM The size of the FlashROM for the application program is 128KB When ADD PROGRAM was selected the PT630 will shows the available FlashROM free information on the screen User may save multiple ap...

Страница 26: ...ROGRAMMING Please download BIOS file Select 1 If BIOS file not found Select YES PROGRAMMING Change BIOS to V 5 X 1 YES 0 NO Select 1 PROGRAMMING Are you sure 1 YES 0 NO Select NO 0 All 1 RAM 2 KEY 3 2...

Страница 27: ...test bar code input by scanning bar code labels Press any key to return to the diagnostics menu 7 RAM BACKUP Follow the instruction displayed on the LCD to press the PWR key to turn the power off and...

Страница 28: ...nal that has an integrated laser scanning module or clip on pen module for bar code reading A rechargeable Li ion battery pack power the PT630 A lithium backup battery preserves data stored in the RAM...

Страница 29: ...ace ports An RS232 I O serial port can be used to communicate with a host PC and normal charge from RS232 cable when cable is connected with 9VDC 1A power adapter Pin Signal Direction Description 1 DC...

Страница 30: ...he PT630 The cradle has provisions for a quick charge circuit to fully charge the Li ion battery pack installed in the unit in about 2 3 hours The cradle also allows users to link the PT630 to host co...

Страница 31: ...ction method the PT630 is directly connected by a null modem cable to the serial port of the host computer This is the way to download or upload files from to your PT630 Note that the communication pa...

Страница 32: ...line you can dial from the PT630 to a remote host computer The computer needs to be attached to a modem through the telephone line After the line is connected the data communication process can start...

Страница 33: ...ocessing will be established when a program running on the PC sends the ESC command consistent with the protocol specified in the PT630 Connection Protocol supported Point to point OFF or MULTI Multi...

Страница 34: ...ake Job icon or select Built Make Job 5 2 2 Uploading JobGen Plus from PT630 to HOST Having collected the data into the PT630 the user can upload one or more collected data files to a PC On PT630 Conn...

Страница 35: ...cation parameter settings Press and hold down CMD key for 2 seconds to enter User mode then select 3 COM in User mode to enter Kermit server mode see On HOST to process file download from Host side No...

Страница 36: ...Press key to power up the PT630 Check the PT630 protocol and communication parameter settings Press and hold down CMD key for 2 seconds to enter User mode then select 3 COM in User mode to enter Kerm...

Страница 37: ...port baud rate data bits parity stop bit matched the Host s setting or Check if the cable is plugged tightly or Check if connectors on cable have correct pin assignment 5 If host can not download appl...

Страница 38: ...ter any other abnormal symptoms Caution The following process will clear all data in PT630 RAM disk memory Reset cold start the PT630 press CMD and simultaneously press 3 in Start Menu press ENTER See...

Страница 39: ...y checked during power on test Both low battery conditions will be signal to the user by a warning message on the LCD When the main battery reaches a low condition the LCD flashes a warning Message Ma...

Страница 40: ...n to screw it anti clockwise 2 Then remove battery cover 3 Take battery out of battery compartment Lithium Back up Battery 1 Refer to the procedure in previous paragraph un screw the backup battery co...

Страница 41: ...t The battery pack will be fully recharged after 2 3 hours The PT630 uses an internal Lithium battery to back up the RAM memory and system real time clock when the main battery stops supplying the req...

Страница 42: ...ain a temporary reduction of capacity due to overcharging A battery left to charge for several weeks may appear to have minimal capacity This type of failure can be remedied by temporarily depleting t...

Отзывы: